+的 ICS 93.080.01
P51
DB44
城镇道路沥青路面预防性养护技术规范
Technical code of asphalt pavement preventive maintenance
for urban road
广东省质量技术监督局 发布
DB44/T 808—2010
目 次
前 言 ............................................................................... II
1 范围 ............................................................................... 1
2 规范性引用文件 ..................................................................... 1
3 术语与代号 ......................................................................... 1
4 总则 ............................................................................... 3
5 基本规定 ........................................................................... 3
6 路面技术状况检测 ................................................................... 3
7 路段选择及措施 ..................................................................... 4
8 时机选择 ........................................................................... 5
9 病害预处治 ......................................................................... 6
10 雾封层 ............................................................................ 6
11 微表处 ............................................................................ 7
12 薄层沥青罩面 ...................................................................... 9
13 质量检查与验收 ................................................................... 14 I
DB44/T 808—2010
前 言
本标准按GB/T 1.1《标准化工作导则 第1部分:标准的结构与编写》给出的规则起草。
本标准由广州市交通委员会提出并归口。
本标准起草单位:广州市市政工程维修处、广州市鸿维城市建设工程设计院、广州市市维建设工程检测服务中心。
本标准主要起草人:殷建军、盛飞、白晓瑾、张恒涓、翟冬梅、苏开志、陈海珊、宋树祥、姚洪春、柴君、王立圆、马智珊。
本标准为首次发布。
本标准适用于城镇道路沥青路面预防性养护技术应用,同时适用于第16届亚洲运动会和第10届亚洲残疾人运动会沥青路面预防性养护工程项目。
II
DB44/T 808—2010
城镇道路沥青路面预防性养护技术规范
1 范围
本规范规定了城镇道路沥青路面技术状况检测,预养护路段选择及措施、预养护时机选择、病害预处治、雾封层、微表处、薄层沥青罩面、质量检查与验收等要求。
本规范适用于各等级城镇道路沥青路面预防性养护工程。
由产权单位自行养护的开发区、居住区内道路和专营单位管理的道路以及工厂、港口、广场、铁路站场内部的专用道路的沥青路面预防性养护工程可参照本规范执行。
本标准仅适用于第16届亚洲运动会和广州2010年亚洲残疾人运动会。
2 规范性引用文件
下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。
CJJ 1 城镇道路工程施工与质量验收规范
CJJ 36 城镇道路养护技术规范
JTG E40 公路土工试验规程
JTG E60 公路路基路面现场测试规程
JTG F41 公路沥青路面再生技术规范
JTG E42 公路工程集料试验规程
JTJ 052 公路工程沥青及沥青混合料试验规程
3 术语与代号
3.1 术语
3.1.1
沥青路面预防性养护 asphalt pavement preventive maintenance
在路面结构强度足够、路面状况良好的情况下,采取的对现有道路系统进行有计划的、基于费用—效益的养护策略。简称预养护。
3.1.2
病害预处治 in-advance distress treatments
在路面实施雾封层、微表处、薄层沥青罩面、沥青路面再生等预养护措施前,针对原路面功能性病害及部分轻微结构性病害,如裂缝、松散、泛油、坑槽、车辙、拥包等病害的预处理技术。
3.1.3
铣刨 milling
用铣刨设备将原道路面层铲除的技术。
3.1.4
灌缝与封缝 crack filling or sealing
采用密封材料充填或封闭裂缝。
3.1.5
1
DB44/T 808—2010
雾封层 fog seal
将乳化沥青稀释液、特制路面保护剂或沥青再生剂涂刷或喷洒在现有沥青路面上形成的封层。
3.1.6
微表处 microsurfacing
采用专用机械设备,在常温条件下将聚合物改性乳化沥青、级配良好的矿料、填料、水和添加剂等按一定的配合比拌合成稀浆混合料,摊铺到原路面上固化成型的薄层。
3.1.7
薄层沥青罩面 thin asphalt layer overlays
将密级配、开级配或间断级配的厂拌沥青混合料直接摊铺在路面上,厚度一般为20mm~40mm的薄层结构。
3.1.8
应力吸收层 stress absorbing membrance interlayer
指铺筑于旧沥青面层与薄层罩面之间的,具有高变形能力的改性沥青层,用于吸收裂缝部位的应力集中,防止沥青路面形成反射裂缝。
3.1.9
沥青路面再生 asphalt pavement recycling
采用专用机械设备对旧沥青路面或者回收沥青路面材料进行处理,并掺加一定比例的新集料、新沥青、再生剂(必要时)等形成路面结构层的技术。按照再生混合料控制和施工温度的不同,沥青路面再生可分为热再生和冷再生;按照施工场合和工艺的不同,沥青路面再生可以分为厂拌再生和就地再生。
3.1.10
沥青再生剂 rejuvenating agent
掺加到再生混合料中,用于恢复已老化沥青性能的添加剂。
3.2 符号或代号
本规范各种符号、代号以及意义详见表1。
表1 符号及代号
2
DB44/T 808—2010
4 总则4.1 为规范城镇道路沥青路面预防性养护应用,提高沥青路面预防性养护技术水平,保证沥青路面预防性养护工程质量,制定本规范。
4.2 预防性养护技术适合于路面结构性能良好或有少量病害的路面,可恢复路面使用功能,延缓路面结构性损坏。
4.3 城镇道路沥青路面预防性养护应制定系统性成套应用方案,有计划、周期性采用适宜的预防性养护措施。
4.4 城镇道路沥青路面预防性养护除执行本规范的规定外,尚应遵守国家和行业有关标准的规定。 5 基本规定
5.1 沥青路面预养护技术措施包括:病害预处治、雾封层、微表处、薄层沥青罩面、沥青路面再生等。
5.2 沥青路面预养护工作内容包括:路面技术状况评定,制定预养护对策,路面病害预处治,预养护技术措施实施,预养护工程检查与验收等。
5.3 沥青路面预养护应以每年的路面技术状况评定结果为依据。宜采用自动化检测设备与路面评估系统评价和预测路面技术路况,提出科学的预养护对策。
5.4 在满足路面使用性能前提下,预养护方案应选择安全可靠、技术先进、经济合理、便于施工的技术措施。
5.5 预养护施工应遵守安全生产、文明施工、环境保护等法律法规规定,应制定相应的安全生产、文明施工、环境保护等技术措施。
5.6 采取沥青路面再生技术应符合JTG F41的规定。
5.7 沥青路面预养护作业防护应符合CJJ 36的规定。
6 路面技术状况检测
6.1 沥青路面检测内容包括路面损坏状况、路面结构强度、路面行驶质量、路面抗滑能力和路面车辙等五项内容。
6.2 沥青路面检测与评价单元应符合下列规定:
——道路的每二个相邻交叉口之间的路段应作为一个单元,交叉口本身宜作为一个单元;当二个相邻交叉口之间的路段大于500m时,每200m~500m作为一个单元,不足200m的按一个单元计。
——应逐个单元进行检测和评价。检测范围包括拟实施预养护路段的全部车道。
6.3 路面状况检测方法和检测频率应符合表2规定:
3
DB44/T 808—2010
表2 路面状况检测
6.4 路面检测宜采用自动化快速检测设备连续进行数据采集,路面损坏状况(包括路面损坏图像)、车辙、抗滑性能等原始检测数据均应长期保存。
6.5 路面技术状况评价应符合CJJ 36的规定。路况检测数据宜采用路面管理系统对检测数据进行分析、评价与储存。
7 路段选择及措施
7.1
预养护路段及其措施确定应结合原路面结构类型、路面病害情况、交通量等级、气候条件以及养护措施的工程特性和经济性等因素。
7.2 当路面结构强度满足表3要求,且预养护指标值域有两项及两项以上满足要求时见表4,可采用预养护技术。
表3 路面结构强度评价标准
表4 预养护指标及值域
4
DB44/T 808—2010
7.3 预养护措施不但应满足路面使用性能的要求而且还应具有良好的效益-费用比,并满足环境保护的要求。
7.4 预养护应根据路面技术状况指标值域采取适当的预养护措施,推荐预养护措施参见表5。当同一路面具有不同技术状况指标时,应按病害程度较重情况选取预养护措施。
表5 路面技术状况指标值域与预养护措施
8 时机选择
8.1 预养护应在路面结构性能良好且路面技术状况评价为B级或以上,或路面使用性能指标值加速衰减前进行。
8.2 预养护时机选择的主要指标为路面结构强度、PCI、RQI、RD、BPN或SFC等,其他的指标如:老化、松散、渗水系数、构造深度等可作为辅助指标。
8.3 预养护时机选择的流程如图1。
5
DB44/T 808—2010
9 病害预处治
9.1 一般规定
9.1.1 采取预养护措施前,应对原沥青路面各种病害进行预处治。宜优先选择机械化设备施工。
9.1.2 病害预处治技术包括:裂缝处治、坑槽修补、路面局部铣刨等。
9.1.3 病害预处治质量的检查与验收标准应符合13章规定。
9.2 裂缝处治
9.2.1 裂缝处治技术包括灌缝、封缝两种。裂缝宽度大于3mm时宜采用灌缝方式,裂缝宽度小于3mm时宜采用封缝方式。
9.2.2 当路面裂缝损坏密度较大时(20%≤ρ≤50%),单一的裂缝修补措施不足以防止路面反射裂缝的出现,应在裂缝修补后加铺应力吸收层,再应用其它的预养护措施。
9.2.3 灌缝应根据裂缝的几何形状开槽,清理、干燥后选择伸缩性良好的灌缝料进行灌缝。常用的灌缝料有热沥青、橡胶沥青、沥青玛蹄脂等。
9.2.4 在城镇道路中采用开槽灌缝工艺时应采取相应的降尘、降噪措施。
9.2.5 封缝无需对裂缝开槽,将裂缝清理、干燥后,用密封材料封闭裂缝。常用的封缝材料有:压缝带、抗裂贴、封缝胶等。
9.3 坑槽修补
9.3.1 坑槽修补的形状应为顺路方向的矩形,坑槽四壁不得松动且必须涂刷粘层油,槽深大于50mm时必须分层摊铺压实。
9.3.2 坑槽修补时宜使用粘结性较强的改性热沥青混合料。
9.4 路面铣刨
9.4.1 沥青面层局部出现拥包、松散、严重泛油等非结构性病害宜先铣刨,再采取其他预养护措施。
9.4.2 沥青路面铣刨的旧料宜再生利用。
10 雾封层
10.1 雾封层主要用于密封原有沥青路面表面层,提高密级配路面的密水性能,防止骨料松散剥落或用于填封微小裂缝和空隙,更新表面被氧化的沥青,也可用在碎石封层上,以固定碎石。
10.2 沥青路面出现轻度到中度细料损失、松散或少量轻微的非活动性裂缝时,可采用雾封层预养护措施。
10.3 雾封层按使用材料分为三大类:普通乳化沥青稀释液、特制路面保护剂和再生剂类。含再生剂类雾封层除具有普通沥青雾封层作用外可对老化路面中的沥青进行再生,恢复其部分路用性能。 10.4 雾封层施工前应做小面积喷洒或涂刷对比试验,根据路面状况确定雾封层用量。
10.5 应用雾封层预养护措施前后,应检测路面抗滑性能,确保施用雾封层后路面抗滑性能满足CJJ 36要求。
10.6 雾封层宜采用专用喷洒设备施工。施工前应清除路面的灰尘、砂土及其它杂物等,施工时路面温度应大于等于15℃,环境湿度宜小于等于80%,下雨前和下雨过程中不得进行雾封层施工。
6
DB44/T 808—2010
10.7 雾封层喷洒完毕后路面应封闭养护,待雾封层干涸后方可开放交通。 10.8 雾封层质量的检查与验收标准应符合13章规定。 11 微表处
11.1 微表处主要用于改善路面抗滑性能,修复或填补轻度车辙。微表处必须使用专用的摊铺机进行摊铺。
11.2 单层微表处适用于旧路面车辙深度不大于15mm的情况,超过15mm的必须分两层铺筑,或先用V字形车辙摊铺箱摊铺。
11.3 微表处必须采用改性乳化沥青,选用的改性乳化沥青必须满足“慢裂快凝”和储存稳定性要求。改性乳化沥青质量应符合表6规定。
表6 微表处用改性乳化沥青技术要求
11.4 微表处应选择坚硬、粗糙、耐磨、洁净的集料。集料质量应符合表7规定。
表7 微表处用粗细集料技术要求
7
DB44/T 808—2010
11.5 微表处混合料配合比设计应充分考虑使用要求、原路面状况、交通量、气候条件等因素,选择适当的微表处类型,确定施工方案。微表处混合料质量应符合表8规定。
表8 微表处混合料技术要求
11.6 施工过程中应对微表处混合料进行抽样检测,抽检项目、频率、允许误差及方法应符合表9规定。
表9 微表处混合料级配稳定性要求
11.7 微表处施工前必须对原路面病害进行预处治,确保原有路面表面平整、密实、清洁。
11.8 施工期间气温应高于10℃,路面过湿、积水及雨天不得施工。施工时遇雨,应在雨后将无法正常成型的材料铲除。
11.9 微表处双层摊铺或微表处车辙填充后再做微表处罩面时,首先摊铺的一层应至少在行车作用下成型24小时后,方可进行第二层微表处施工。
11.10 混合料固化成型前禁止一切车辆和行人通行,到达固化时间后应尽早开放交通。 11.11 微表处质量的检查与验收应符合13章规定。
8
DB44/T 808—2010
12 薄层沥青罩面
12.1 薄层沥青罩面适用于路面结构强度足够,没有明显结构性破损及存在较严重功能性病害的路面。可修复路面的轻微裂缝、轻微松散、老化、泛油和磨光等表面病害。
12.2 沥青混合料按拌和温度分类有:冷拌沥青混合料(拌和温度15℃~40℃)、温拌沥青混合料(拌和温度100℃~130℃)、热拌沥青混合料。
12.3 薄层沥青罩面结构层厚度一般为20mm~40mm,其中结构层厚度为20mm~30mm称超薄磨耗层。超薄磨耗层应用较普遍的级配类型有UTAC-10和Novachip,薄层热拌沥青混合料应用较普遍的级配类型有AC-13C,SMA-10、SMA-13和OGFC-10。
12.4 沥青混合料宜采用改性沥青、高黏度改性沥青或橡胶粉改性沥青。技术要求应符合表10规定。
表10 聚合物改性沥青(SBS类)、橡胶沥青、高黏度改性沥青技术要求
9
DB44/T 808—2010
12.5 沥青混合料中粗集料应洁净、干燥、表面粗糙,形状接近立方体。质量应符合表11规定。
表11 薄层沥青罩面粗集料质量要求
12.6 沥青混合料中细集料应洁净、干燥、无风化、无杂质,并有适当的颗粒级配。质量应符合表12规定。细集料的洁净程度,天然砂以小于0.075mm含量的百分数表示,石屑和机制砂以砂当量(适用于0~ 4.75mm)或亚甲蓝值(适用于 0~ 2.36mm 或 0~0.15mm)表示。
表12 薄层沥青罩面细集料质量要求
10
DB44/T 808—2010
12.7 沥青混合料的矿粉必须采用碱性或中性的憎水性石料经磨细得到的矿粉。质量应符合表13规定。
表13 薄层沥青罩面矿粉质量要求
12.8 沥青玛蹄脂混合料(SMA)中掺加的纤维稳定剂宜选用木质素纤维、矿物纤维等。纤维应在250℃的干拌温度不变质、不发脆,使用纤维必须符合环保要求,不危害身体健康。纤维质量应符合表14规定。
表14 木质素纤维质量技术要求
12.9 薄层沥青罩面施工时气温不得低于10℃,雨天、路面潮湿、大风等情况下禁止施工。热拌沥青混合料的施工温度应符合表15规定。
11
DB44/T 808—2010
表15 热拌沥青混合料的施工温度
12.10 本规范采用马歇尔试验配合比设计方法,沥青混合料技术要求应符合表16的规定。
表16 薄层罩面沥青混合料试验技术指标要求
12
DB44/T 808—2010
12.11 沥青拌和站必须按表17对混合料生产过程进行质量控制。
表17 薄层罩面沥青混合料拌和温度、级配质量要求
12.12 薄层沥青罩面铺筑过程中质量检查内容、频率、允许差应符合表18规定。
表18 薄层沥青罩面施工过程中工程质量的控制标准
13
DB44/T 808—2010
12.13 粘层油应采用改性乳化沥青,正式喷洒前应进行试喷以准确控制实际喷洒量,防止漏撒或过撒。一般为0.5L/m~ 1.2L/m。
12.14 薄层沥青罩面混合料的松铺系数应根据混合料的类型由试铺试压确定。一般为1.10~1.20。 12.15 薄层沥青罩面施工应配备足够数量的压路机,选择合理的压路机组合方式以及适当的初压、复压、终压碾压遍数,以达到最佳碾压效果。
12.16 压路机碾压轮在碾压过程中应保持清洁,有混合料粘轮应立即清除。对钢轮可涂刷隔离剂或防粘结剂。当采用向碾压轮喷水的方式时,必须严格控制喷水量且成雾状,不得漫流,以防混合料降温过快。 12.17 沥青路面的施工必须接缝紧密、连接平顺,不得产生明显的接缝离析。横向接缝应采用垂直的平接缝。
12.18 热拌沥青混合料路面应待摊铺层完全自然冷却,混合料表面温度低于50℃后方可开放交通,严禁采取洒水方式进行降温。
12.19 薄层沥青罩面质量的检查与验收应符合13章规定。 13 质量检查与验收 13.1 一般规定
13.1.1 沥青路面预养护施工各工序的质量应达到本规范规定的质量标准,确保施工质量稳定性。 13.1.2 施工中所有材料都应按规定取样检测。
13.1.3 施工前应对沥青拌和楼、摊铺机、压路机等各种施工机械和设备进行调试,对机械设备的配套情况、技术性能、传感器计量精度等进行认真检查、标定。 13.2 检查与验收标准
13.2.1 病害预处治质量检查与验收标准应符合表19、表20规定。
表19 裂缝处治质量标准
2
2
表20 铣刨、坑槽修补质量标准
14
DB44/T 808—2010
13.2.2 雾封层工程质量检查与验收标准应符合表21规定。
表21 雾封层质量标准
13.2.3微表处工程质量检查与验收标准应符合表22规定。
表22 微表处工程质量验收标准
15
DB44/T 808—2010
13.2.4 薄层沥青罩面工程质量检查与验收标准应符合表23规定。
表23 薄层沥青罩面工程质量验收标准
13.3 预养护工程竣工资料
13.3.1 预养护工程的技术资料应及时归档、保存。竣工资料包括:路面检测资料、预养护实施方案、各项检查记录、检验报告和图片资料等。
13.3.2 养护单位宜建立道路养护信息管理系统,预养护资料信息应存入信息管理系统。
16
+的 ICS 93.080.01
P51
DB44
城镇道路沥青路面预防性养护技术规范
Technical code of asphalt pavement preventive maintenance
for urban road
广东省质量技术监督局 发布
DB44/T 808—2010
目 次
前 言 ............................................................................... II
1 范围 ............................................................................... 1
2 规范性引用文件 ..................................................................... 1
3 术语与代号 ......................................................................... 1
4 总则 ............................................................................... 3
5 基本规定 ........................................................................... 3
6 路面技术状况检测 ................................................................... 3
7 路段选择及措施 ..................................................................... 4
8 时机选择 ........................................................................... 5
9 病害预处治 ......................................................................... 6
10 雾封层 ............................................................................ 6
11 微表处 ............................................................................ 7
12 薄层沥青罩面 ...................................................................... 9
13 质量检查与验收 ................................................................... 14 I
DB44/T 808—2010
前 言
本标准按GB/T 1.1《标准化工作导则 第1部分:标准的结构与编写》给出的规则起草。
本标准由广州市交通委员会提出并归口。
本标准起草单位:广州市市政工程维修处、广州市鸿维城市建设工程设计院、广州市市维建设工程检测服务中心。
本标准主要起草人:殷建军、盛飞、白晓瑾、张恒涓、翟冬梅、苏开志、陈海珊、宋树祥、姚洪春、柴君、王立圆、马智珊。
本标准为首次发布。
本标准适用于城镇道路沥青路面预防性养护技术应用,同时适用于第16届亚洲运动会和第10届亚洲残疾人运动会沥青路面预防性养护工程项目。
II
DB44/T 808—2010
城镇道路沥青路面预防性养护技术规范
1 范围
本规范规定了城镇道路沥青路面技术状况检测,预养护路段选择及措施、预养护时机选择、病害预处治、雾封层、微表处、薄层沥青罩面、质量检查与验收等要求。
本规范适用于各等级城镇道路沥青路面预防性养护工程。
由产权单位自行养护的开发区、居住区内道路和专营单位管理的道路以及工厂、港口、广场、铁路站场内部的专用道路的沥青路面预防性养护工程可参照本规范执行。
本标准仅适用于第16届亚洲运动会和广州2010年亚洲残疾人运动会。
2 规范性引用文件
下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。
CJJ 1 城镇道路工程施工与质量验收规范
CJJ 36 城镇道路养护技术规范
JTG E40 公路土工试验规程
JTG E60 公路路基路面现场测试规程
JTG F41 公路沥青路面再生技术规范
JTG E42 公路工程集料试验规程
JTJ 052 公路工程沥青及沥青混合料试验规程
3 术语与代号
3.1 术语
3.1.1
沥青路面预防性养护 asphalt pavement preventive maintenance
在路面结构强度足够、路面状况良好的情况下,采取的对现有道路系统进行有计划的、基于费用—效益的养护策略。简称预养护。
3.1.2
病害预处治 in-advance distress treatments
在路面实施雾封层、微表处、薄层沥青罩面、沥青路面再生等预养护措施前,针对原路面功能性病害及部分轻微结构性病害,如裂缝、松散、泛油、坑槽、车辙、拥包等病害的预处理技术。
3.1.3
铣刨 milling
用铣刨设备将原道路面层铲除的技术。
3.1.4
灌缝与封缝 crack filling or sealing
采用密封材料充填或封闭裂缝。
3.1.5
1
DB44/T 808—2010
雾封层 fog seal
将乳化沥青稀释液、特制路面保护剂或沥青再生剂涂刷或喷洒在现有沥青路面上形成的封层。
3.1.6
微表处 microsurfacing
采用专用机械设备,在常温条件下将聚合物改性乳化沥青、级配良好的矿料、填料、水和添加剂等按一定的配合比拌合成稀浆混合料,摊铺到原路面上固化成型的薄层。
3.1.7
薄层沥青罩面 thin asphalt layer overlays
将密级配、开级配或间断级配的厂拌沥青混合料直接摊铺在路面上,厚度一般为20mm~40mm的薄层结构。
3.1.8
应力吸收层 stress absorbing membrance interlayer
指铺筑于旧沥青面层与薄层罩面之间的,具有高变形能力的改性沥青层,用于吸收裂缝部位的应力集中,防止沥青路面形成反射裂缝。
3.1.9
沥青路面再生 asphalt pavement recycling
采用专用机械设备对旧沥青路面或者回收沥青路面材料进行处理,并掺加一定比例的新集料、新沥青、再生剂(必要时)等形成路面结构层的技术。按照再生混合料控制和施工温度的不同,沥青路面再生可分为热再生和冷再生;按照施工场合和工艺的不同,沥青路面再生可以分为厂拌再生和就地再生。
3.1.10
沥青再生剂 rejuvenating agent
掺加到再生混合料中,用于恢复已老化沥青性能的添加剂。
3.2 符号或代号
本规范各种符号、代号以及意义详见表1。
表1 符号及代号
2
DB44/T 808—2010
4 总则4.1 为规范城镇道路沥青路面预防性养护应用,提高沥青路面预防性养护技术水平,保证沥青路面预防性养护工程质量,制定本规范。
4.2 预防性养护技术适合于路面结构性能良好或有少量病害的路面,可恢复路面使用功能,延缓路面结构性损坏。
4.3 城镇道路沥青路面预防性养护应制定系统性成套应用方案,有计划、周期性采用适宜的预防性养护措施。
4.4 城镇道路沥青路面预防性养护除执行本规范的规定外,尚应遵守国家和行业有关标准的规定。 5 基本规定
5.1 沥青路面预养护技术措施包括:病害预处治、雾封层、微表处、薄层沥青罩面、沥青路面再生等。
5.2 沥青路面预养护工作内容包括:路面技术状况评定,制定预养护对策,路面病害预处治,预养护技术措施实施,预养护工程检查与验收等。
5.3 沥青路面预养护应以每年的路面技术状况评定结果为依据。宜采用自动化检测设备与路面评估系统评价和预测路面技术路况,提出科学的预养护对策。
5.4 在满足路面使用性能前提下,预养护方案应选择安全可靠、技术先进、经济合理、便于施工的技术措施。
5.5 预养护施工应遵守安全生产、文明施工、环境保护等法律法规规定,应制定相应的安全生产、文明施工、环境保护等技术措施。
5.6 采取沥青路面再生技术应符合JTG F41的规定。
5.7 沥青路面预养护作业防护应符合CJJ 36的规定。
6 路面技术状况检测
6.1 沥青路面检测内容包括路面损坏状况、路面结构强度、路面行驶质量、路面抗滑能力和路面车辙等五项内容。
6.2 沥青路面检测与评价单元应符合下列规定:
——道路的每二个相邻交叉口之间的路段应作为一个单元,交叉口本身宜作为一个单元;当二个相邻交叉口之间的路段大于500m时,每200m~500m作为一个单元,不足200m的按一个单元计。
——应逐个单元进行检测和评价。检测范围包括拟实施预养护路段的全部车道。
6.3 路面状况检测方法和检测频率应符合表2规定:
3
DB44/T 808—2010
表2 路面状况检测
6.4 路面检测宜采用自动化快速检测设备连续进行数据采集,路面损坏状况(包括路面损坏图像)、车辙、抗滑性能等原始检测数据均应长期保存。
6.5 路面技术状况评价应符合CJJ 36的规定。路况检测数据宜采用路面管理系统对检测数据进行分析、评价与储存。
7 路段选择及措施
7.1
预养护路段及其措施确定应结合原路面结构类型、路面病害情况、交通量等级、气候条件以及养护措施的工程特性和经济性等因素。
7.2 当路面结构强度满足表3要求,且预养护指标值域有两项及两项以上满足要求时见表4,可采用预养护技术。
表3 路面结构强度评价标准
表4 预养护指标及值域
4
DB44/T 808—2010
7.3 预养护措施不但应满足路面使用性能的要求而且还应具有良好的效益-费用比,并满足环境保护的要求。
7.4 预养护应根据路面技术状况指标值域采取适当的预养护措施,推荐预养护措施参见表5。当同一路面具有不同技术状况指标时,应按病害程度较重情况选取预养护措施。
表5 路面技术状况指标值域与预养护措施
8 时机选择
8.1 预养护应在路面结构性能良好且路面技术状况评价为B级或以上,或路面使用性能指标值加速衰减前进行。
8.2 预养护时机选择的主要指标为路面结构强度、PCI、RQI、RD、BPN或SFC等,其他的指标如:老化、松散、渗水系数、构造深度等可作为辅助指标。
8.3 预养护时机选择的流程如图1。
5
DB44/T 808—2010
9 病害预处治
9.1 一般规定
9.1.1 采取预养护措施前,应对原沥青路面各种病害进行预处治。宜优先选择机械化设备施工。
9.1.2 病害预处治技术包括:裂缝处治、坑槽修补、路面局部铣刨等。
9.1.3 病害预处治质量的检查与验收标准应符合13章规定。
9.2 裂缝处治
9.2.1 裂缝处治技术包括灌缝、封缝两种。裂缝宽度大于3mm时宜采用灌缝方式,裂缝宽度小于3mm时宜采用封缝方式。
9.2.2 当路面裂缝损坏密度较大时(20%≤ρ≤50%),单一的裂缝修补措施不足以防止路面反射裂缝的出现,应在裂缝修补后加铺应力吸收层,再应用其它的预养护措施。
9.2.3 灌缝应根据裂缝的几何形状开槽,清理、干燥后选择伸缩性良好的灌缝料进行灌缝。常用的灌缝料有热沥青、橡胶沥青、沥青玛蹄脂等。
9.2.4 在城镇道路中采用开槽灌缝工艺时应采取相应的降尘、降噪措施。
9.2.5 封缝无需对裂缝开槽,将裂缝清理、干燥后,用密封材料封闭裂缝。常用的封缝材料有:压缝带、抗裂贴、封缝胶等。
9.3 坑槽修补
9.3.1 坑槽修补的形状应为顺路方向的矩形,坑槽四壁不得松动且必须涂刷粘层油,槽深大于50mm时必须分层摊铺压实。
9.3.2 坑槽修补时宜使用粘结性较强的改性热沥青混合料。
9.4 路面铣刨
9.4.1 沥青面层局部出现拥包、松散、严重泛油等非结构性病害宜先铣刨,再采取其他预养护措施。
9.4.2 沥青路面铣刨的旧料宜再生利用。
10 雾封层
10.1 雾封层主要用于密封原有沥青路面表面层,提高密级配路面的密水性能,防止骨料松散剥落或用于填封微小裂缝和空隙,更新表面被氧化的沥青,也可用在碎石封层上,以固定碎石。
10.2 沥青路面出现轻度到中度细料损失、松散或少量轻微的非活动性裂缝时,可采用雾封层预养护措施。
10.3 雾封层按使用材料分为三大类:普通乳化沥青稀释液、特制路面保护剂和再生剂类。含再生剂类雾封层除具有普通沥青雾封层作用外可对老化路面中的沥青进行再生,恢复其部分路用性能。 10.4 雾封层施工前应做小面积喷洒或涂刷对比试验,根据路面状况确定雾封层用量。
10.5 应用雾封层预养护措施前后,应检测路面抗滑性能,确保施用雾封层后路面抗滑性能满足CJJ 36要求。
10.6 雾封层宜采用专用喷洒设备施工。施工前应清除路面的灰尘、砂土及其它杂物等,施工时路面温度应大于等于15℃,环境湿度宜小于等于80%,下雨前和下雨过程中不得进行雾封层施工。
6
DB44/T 808—2010
10.7 雾封层喷洒完毕后路面应封闭养护,待雾封层干涸后方可开放交通。 10.8 雾封层质量的检查与验收标准应符合13章规定。 11 微表处
11.1 微表处主要用于改善路面抗滑性能,修复或填补轻度车辙。微表处必须使用专用的摊铺机进行摊铺。
11.2 单层微表处适用于旧路面车辙深度不大于15mm的情况,超过15mm的必须分两层铺筑,或先用V字形车辙摊铺箱摊铺。
11.3 微表处必须采用改性乳化沥青,选用的改性乳化沥青必须满足“慢裂快凝”和储存稳定性要求。改性乳化沥青质量应符合表6规定。
表6 微表处用改性乳化沥青技术要求
11.4 微表处应选择坚硬、粗糙、耐磨、洁净的集料。集料质量应符合表7规定。
表7 微表处用粗细集料技术要求
7
DB44/T 808—2010
11.5 微表处混合料配合比设计应充分考虑使用要求、原路面状况、交通量、气候条件等因素,选择适当的微表处类型,确定施工方案。微表处混合料质量应符合表8规定。
表8 微表处混合料技术要求
11.6 施工过程中应对微表处混合料进行抽样检测,抽检项目、频率、允许误差及方法应符合表9规定。
表9 微表处混合料级配稳定性要求
11.7 微表处施工前必须对原路面病害进行预处治,确保原有路面表面平整、密实、清洁。
11.8 施工期间气温应高于10℃,路面过湿、积水及雨天不得施工。施工时遇雨,应在雨后将无法正常成型的材料铲除。
11.9 微表处双层摊铺或微表处车辙填充后再做微表处罩面时,首先摊铺的一层应至少在行车作用下成型24小时后,方可进行第二层微表处施工。
11.10 混合料固化成型前禁止一切车辆和行人通行,到达固化时间后应尽早开放交通。 11.11 微表处质量的检查与验收应符合13章规定。
8
DB44/T 808—2010
12 薄层沥青罩面
12.1 薄层沥青罩面适用于路面结构强度足够,没有明显结构性破损及存在较严重功能性病害的路面。可修复路面的轻微裂缝、轻微松散、老化、泛油和磨光等表面病害。
12.2 沥青混合料按拌和温度分类有:冷拌沥青混合料(拌和温度15℃~40℃)、温拌沥青混合料(拌和温度100℃~130℃)、热拌沥青混合料。
12.3 薄层沥青罩面结构层厚度一般为20mm~40mm,其中结构层厚度为20mm~30mm称超薄磨耗层。超薄磨耗层应用较普遍的级配类型有UTAC-10和Novachip,薄层热拌沥青混合料应用较普遍的级配类型有AC-13C,SMA-10、SMA-13和OGFC-10。
12.4 沥青混合料宜采用改性沥青、高黏度改性沥青或橡胶粉改性沥青。技术要求应符合表10规定。
表10 聚合物改性沥青(SBS类)、橡胶沥青、高黏度改性沥青技术要求
9
DB44/T 808—2010
12.5 沥青混合料中粗集料应洁净、干燥、表面粗糙,形状接近立方体。质量应符合表11规定。
表11 薄层沥青罩面粗集料质量要求
12.6 沥青混合料中细集料应洁净、干燥、无风化、无杂质,并有适当的颗粒级配。质量应符合表12规定。细集料的洁净程度,天然砂以小于0.075mm含量的百分数表示,石屑和机制砂以砂当量(适用于0~ 4.75mm)或亚甲蓝值(适用于 0~ 2.36mm 或 0~0.15mm)表示。
表12 薄层沥青罩面细集料质量要求
10
DB44/T 808—2010
12.7 沥青混合料的矿粉必须采用碱性或中性的憎水性石料经磨细得到的矿粉。质量应符合表13规定。
表13 薄层沥青罩面矿粉质量要求
12.8 沥青玛蹄脂混合料(SMA)中掺加的纤维稳定剂宜选用木质素纤维、矿物纤维等。纤维应在250℃的干拌温度不变质、不发脆,使用纤维必须符合环保要求,不危害身体健康。纤维质量应符合表14规定。
表14 木质素纤维质量技术要求
12.9 薄层沥青罩面施工时气温不得低于10℃,雨天、路面潮湿、大风等情况下禁止施工。热拌沥青混合料的施工温度应符合表15规定。
11
DB44/T 808—2010
表15 热拌沥青混合料的施工温度
12.10 本规范采用马歇尔试验配合比设计方法,沥青混合料技术要求应符合表16的规定。
表16 薄层罩面沥青混合料试验技术指标要求
12
DB44/T 808—2010
12.11 沥青拌和站必须按表17对混合料生产过程进行质量控制。
表17 薄层罩面沥青混合料拌和温度、级配质量要求
12.12 薄层沥青罩面铺筑过程中质量检查内容、频率、允许差应符合表18规定。
表18 薄层沥青罩面施工过程中工程质量的控制标准
13
DB44/T 808—2010
12.13 粘层油应采用改性乳化沥青,正式喷洒前应进行试喷以准确控制实际喷洒量,防止漏撒或过撒。一般为0.5L/m~ 1.2L/m。
12.14 薄层沥青罩面混合料的松铺系数应根据混合料的类型由试铺试压确定。一般为1.10~1.20。 12.15 薄层沥青罩面施工应配备足够数量的压路机,选择合理的压路机组合方式以及适当的初压、复压、终压碾压遍数,以达到最佳碾压效果。
12.16 压路机碾压轮在碾压过程中应保持清洁,有混合料粘轮应立即清除。对钢轮可涂刷隔离剂或防粘结剂。当采用向碾压轮喷水的方式时,必须严格控制喷水量且成雾状,不得漫流,以防混合料降温过快。 12.17 沥青路面的施工必须接缝紧密、连接平顺,不得产生明显的接缝离析。横向接缝应采用垂直的平接缝。
12.18 热拌沥青混合料路面应待摊铺层完全自然冷却,混合料表面温度低于50℃后方可开放交通,严禁采取洒水方式进行降温。
12.19 薄层沥青罩面质量的检查与验收应符合13章规定。 13 质量检查与验收 13.1 一般规定
13.1.1 沥青路面预养护施工各工序的质量应达到本规范规定的质量标准,确保施工质量稳定性。 13.1.2 施工中所有材料都应按规定取样检测。
13.1.3 施工前应对沥青拌和楼、摊铺机、压路机等各种施工机械和设备进行调试,对机械设备的配套情况、技术性能、传感器计量精度等进行认真检查、标定。 13.2 检查与验收标准
13.2.1 病害预处治质量检查与验收标准应符合表19、表20规定。
表19 裂缝处治质量标准
2
2
表20 铣刨、坑槽修补质量标准
14
DB44/T 808—2010
13.2.2 雾封层工程质量检查与验收标准应符合表21规定。
表21 雾封层质量标准
13.2.3微表处工程质量检查与验收标准应符合表22规定。
表22 微表处工程质量验收标准
15
DB44/T 808—2010
13.2.4 薄层沥青罩面工程质量检查与验收标准应符合表23规定。
表23 薄层沥青罩面工程质量验收标准
13.3 预养护工程竣工资料
13.3.1 预养护工程的技术资料应及时归档、保存。竣工资料包括:路面检测资料、预养护实施方案、各项检查记录、检验报告和图片资料等。
13.3.2 养护单位宜建立道路养护信息管理系统,预养护资料信息应存入信息管理系统。
16