重庆大学给排水专业毕业实习报告

目 录

一 毕业实习绪论...........................................................................................................................2

1.实习目的 .............................................................................................................................2

2.实习要求 .............................................................................................................................2

3.实习内容...........................................................................................................................3

3.1. 净水厂的实习 .........................................................................................................................3

3.2. 污水处理厂的实习..................................................................................................................4

3.3. 建筑给排水实习 .....................................................................................................................5

3.4 专业参观.................................................................................................................................6

3.5 听专家做有关设计报告............................................................................................................6

4.实习地点 .............................................................................................................................6

5.指导教师 .............................................................................................................................7

二 分散实习篇 ..............................................................................................................................7

1.排水工程——习水县污水处理厂 ..........................................................................................7

1.1 习水县污水处理厂概况............................................................................................................7

1.2 习水县污水处理厂工艺流程.....................................................................................................8

1.3 核心工艺的构筑物介绍.......................................................................................................... 10

1.4 脱氮除磷工艺原理及过程阐述 ............................................................................................... 16

1.5 调试与运行 ........................................................................................................................... 17

1.6 运行故障问题与解决 ............................................................................................................. 19

1.7 结论...................................................................................................................................... 20

1.8 存在的问题与今后发展趋势................................................................................................... 21

2.建筑给水排水工程——习水县人民医院门诊综合大楼 ........................................................ 22

2.1 习水县人民医院简介 ............................................................................................................. 22

2.2 习水县人民医院建筑物概况................................................................................................... 23

2.3 医院建筑给水排水的特点 ...................................................................................................... 23

2.4 医院建筑给排水系统设计心得 ............................................................................................... 24

三 集中实习篇 ............................................................................................................................ 25

1.听专家的报告 .................................................................................................................... 25

1.1 给水工程设计的讲座 ............................................................................................................. 25

1.2 建筑给水排水工程设计的讲座 ............................................................................................... 27

1.3 排水工程设计的讲座 ............................................................................................................. 27

1.4 给排水规划的讲座................................................................................................................. 28

1.5 给排水消防工程的讲座.......................................................................................................... 30

2.参观西南医院建筑给水排水系统 ........................................................................................ 31

四 实习收获与心得体会 .............................................................................................................. 31 参看文献: ................................................................................................................................. 31

一 毕业实习绪论

1.实习目的

学生参加实习是理论学习和时间锻炼相结合的重要机会,是提高政治思想水平和业务素质的重要环节。

给排水工程实习是给排水专业学生必须完成的课程之一。通过实习,可以是学生了解社会,接触实际,增强群众观点,劳动观念,和社会主义的事业心,责任感,提高政治思想觉悟;通过学习,可以获得给谁排水的世界只是,巩固所学理论,培养初步的实际工作能力和专业技能,使学校教育与社会教育的更好的结合,为毕业设计做好准备。

毕业实习是《给水排水工程》专业学生的主要教学环节之一。其目的与要求如下:

(1) 熟悉和掌握室外给水排水工程,建筑给水排水工程的设计内容、步骤与方法;

(2) 了解水厂、污水处理厂和建筑给水排水等方面的运转管理经验;

(3) 了解工程技术人员和工人师傅在科研、技术革新方面的成就,学习他们的积极性和创造精神,从而提高学生学习的积极性与自觉性;

(4) 扩大学生的专业知识范围,加深和巩固所学的理论知识。

通过参观学习、资料查询以及专题讲座等实习内容,收集与毕业设计(论文)题目有关的资料,为毕业设计(论文)作好准备。

2.实习要求

(1) 学生要重视向实际学习,向工人学习,多问多记,记号笔记,写好实习报告。

(2) 严格遵守各项规章制度。

① 学生往返实习场所应该集体行动,不得无故擅自行动,确有原因者,

必学向知道老师说明并应该征得知道老师的同意。

②学生实习期间不准请假,特殊情况需持证明经过知道老师的批准,否则按旷课处理。

③严格遵守工厂的规章制度和操作规程,主意安全,遵守保密制度,爱护公共财务。

④学生要注意路途安全,不得打架斗殴。

通过本课程的学习,熟悉和掌握室外给水排水工程,建筑给水排水工程的设计内容、步骤与方法;了解室外给水排水工程,建筑给水排水工程在实际应用中所产生的问题以及解决问题的方法;扩大学生的专业知识范围,加深和巩固所学的理论知识;收集与毕业设计(论文)题目有关的资料,为毕业设计(论文)作好准备。

3.实习内容

本次的实习中共分为三部分:给水工程、排水工程、建筑给排水工程。

3.1. 净水厂的实习

水厂实习按给水工艺流程分取水、混凝沉淀、过滤消毒、送水泵站四个部分,深入了解,重点解剖。水厂实习的内容和要求如下:

(1)熟悉了解水厂布置及工艺流程;

(2)熟悉了解水源情况(水源水量、水位、流速及水质情况);取水构筑物的型式与构造,操作管理的内容和方法;取水泵站的布置和附属设备,水泵的操作规程,运行中存在的问题。

(3)熟悉了解混凝剂情况;混凝沉淀,澄清、气浮等构筑物的型式、构造、基本设计参数以及运行管理内容、方法和经验。

(4) 熟悉了解过滤和消毒设备的型式、构造、工作过程、基本设计参数以及运行管理内容、方法和经验。

(5) 熟悉了解送水泵站的工作特点、水泵布置和调度方式、水泵启动、停车的操作程序及注意事项,水泵运行记录,泵站附属设备,泵站供电方式及设备。

(6) 了解水厂自动化设施及运行情况。

(7) 了解水厂化验室的任务,化验项目和方法;主要化验设备情况。

(8) 了解水厂组织管理及水厂运行的技术经济指标,包括人员编制,漏失水量和水厂自用水量,每吨水的电耗、制水成本和水价。

3.2. 污水处理厂的实习

污水处理厂实习分为泵房和空压机房、曝气池和沉淀池,化验室等三个部分,深入了解,重点解剖。污水处理厂实习内容如下:

(1)熟悉和了解污水厂布置,污水处理和污泥处置的工艺流程,处理水量,进出水水质和处理效率;

(2)熟悉了解各项构筑物的形式和构造,基本设计参数,运行方式和运行管理的各项控制指标。

对于格栅有:格栅间距、栅间流速、截留污物量和污物消除方式;

对于沉砂池有:水流速度、停留时间、沉砂量和排砂方式;

对于沉淀池(初次、二次)有:水流速度(上升流速、水平流速和板间流速)、停留时间、表面负荷率、出流堰的单宽流量、排泥方式和排泥间隔时间(或连续排泥);

对于曝气池有:污泥负荷率、曝气时间、混合液污泥浓度、污泥指数、污泥回流比和回流污泥浓度等。

(3)熟悉和了解污水泵房、空压机房的操作规程、工作情况、自动化控制技术及有关指标;

(4)熟悉和了解化验室工作情况,化验项目及方法,各主要项目的分析数据,主要化验设备,化验室的总体布置情况;

(5)了解污水厂的组织管理及运行的各项技术经济指标,包括人员编制、电耗、污水处理成本等。

3.3. 建筑给排水实习

(1)全面地、系统地了解建筑给水排水工程的设计程序,各设计阶段要求的设计内容和深度,设计方案的比较和选择,图纸的表达方法以及说明书编制等。

(2)了解建筑性质、用途、体积、层高、耐火等级、结构情况、使用人数、卫生器具和用水设备布置情况,电气和暖通专业管线布置情况,以及气候条件。

(3)了解用户、建筑对给水,消防和热水供应的要求(如水量、水质、水压、水温等),对供水安全程度的要求,以及对环境安静程度和建筑美观等的要求。

(4)了解工程的水源情况,室外的市政给水管道设置情况、以及管径、水压、水温和供水的可靠性。

(5)了解污、废水的排放条件,市政排水管网对建筑排水的处理要求,室外排水体制,室外污废水和雨水管道设置情况。

(6)重点了解该高层建筑给水、消防及热水供应系统的组成,供水方式,设备及管道的平面布置,系统竖向分区情况。

(7)重点了解该建筑冷、热水用水量标准,生活及消防设计流量的确定,空调用水量,热水设计水温的确定,高位水箱,分区水箱及地面贮水池容积的确定。

(8)重点了解该建筑热水供应系统热源的选择,水的加热方法、加热设备的选择。锅炉、加热器、水泵及主要附属设备的型号、数量及其设备的布置情况。

(9)重点了解该建筑的排水系统体制,排水系统的组成,排水方式,高层建筑排水通气系统的设置情况。

(10)了解空调冷却用水供水方式,冷却设备的型号、性能、设置情况。

(11)了解高层建筑给排水工程有关保温、防腐、防震及防噪音技术措施。

(12)收集工程采用的新技术、新设备和新材料。设计和施工的先进经验,设计和使用中存在的问题。

3.4 专业参观

参观目的:使学生见到更多类型的给排水工程设施,扩大学生的专业知识面。

参观安排:可在学生分散实习或集中实习进行。

给水参观内容:城市给水处理工程、增压泵站、新型净水构筑物、离子交换移动床和固定床软化设备、电渗析除盐、各种填料冷却塔等。

排水参观内容:城市污水处理工程、中途泵站、雨水泵站、化纤废水处理、印染废水处理、电镀废水处理、含有废水处理、肉联厂废水处理、食品加工厂废水处理等。

建筑给水排水参观内容:高层建筑中的宾馆、大型公共建筑物、住宅等。 参观期间:学生应认真记录技术人员、工人师傅介绍的参观内容,绘制必要的草图,并及时整理参观笔记。

3.5 听专家做有关设计报告

4.实习地点

4.1 贵州省习水县供水公司污水处理厂

4.2 贵州省习水县人民医院

4.3 西南医院

5.指导教师

重庆大学给水排水工程系主任 张勤 教授

贵州省习水县供水公司污水处理厂生产科主任 李健 助理工程师

贵州省习水县人民医院门诊部主任 张勇 副主任医师

二 分散实习篇

1.排水工程——习水县污水处理厂

1.1 习水县污水处理厂概况

习水县污水处理厂现隶属习水县供水公司,接受习水县环境保护局、习水县环境监察大队的监督和指导。现有员工19人,具有中级职称的3人,具有初级职称的8人,维修工6人,门卫1人,后勤1人。该厂始建于2004年9月,2007年8月竣工,设计处理规模是1.5万m3/日。建设单位:习水县天生桥污水处理工程有限公司;设计单位:贵州省建筑设计研究院;监理单位:贵阳科力建设工程监理有限公司;施工单位:水城钢铁(集团)赛得建设有限公司;

该污水处理厂主要处理来自主城东皇镇东城区以及西城区的生活污水,处理后排入东风湖水库。核心工艺是一体化氧化沟技术,进出水都有在线水质水量的监控措施。由于城市排水管网还不完善,故对于部分老城区,尤其是菜市场至小龙口段的生活污水未能收集进入管网,因此目前实际污水处理量一般为4400~4800m3/d,夏季可达6000m3/d。处理标准执行一级B标。剩余污泥经压榨脱水后直接外运。

1.2 习水县污水处理厂工艺流程

习水县污水处理厂位于习水县县城所在地东皇镇以西约2.5公里的银杏村,占地1.8公顷,服务人口10万人,海拔1120m,常年最低气温-3°,最高气温32°,平均气温14.8°,夏无酷暑冬无严寒,主导风向为西南风,地质以砂岩为主,地基承载力较好,无滑坡无坍塌。该厂包含预处理站和二级处理厂两部分,其中预处理站位于六角洞村,二级处理与污泥处理部分位于该厂本部。该厂处理污水执行一级B标排放标准。

位于六角洞的预处理站接受来自主城的生活污水,设有粗格栅、提升泵房和细格栅,之后压力管输送至污水处理厂。

粗格栅一用一备,采用HGS-1300回转弧形格栅除污机,栅前流速

0.8m/s,栅条间距为25mm,总宽1.0m,功率0.55KW。每日的栅渣量为28kg,机械清渣。

提升泵房占地78m2,包含配电间和操作间、机房,人员配置是2人,负责机房的正常运转和设备维修。泵两用一备,采用100WDL-15,设计Q130m3/h,扬程为14m,转速达到1500r/min,电机型号Y132M-4B5,功率7.5KW,效率66%,重量300Kg。

细格栅一用一备,采用型号HG-1200回转弧形格栅除污机,栅前流速1.0m/s,栅条间距为10mm,总宽1.0m,功率0.45KW,每日的栅渣量为50kg,机械清渣。

细格栅之后,污水由DN600的两根压力干管输送至污水处理厂,钢管,长度1.5km。

压力管来水进入污水处理厂的辐流式沉砂池。

辐流沉砂池设计沉砂时间1min,设计水力表面负荷为150m3/m2·h,有效水深2.0m,池径6.0m,出水堰负荷2.8L/(s·m),机械排泥,排泥机械旋转速度1r/h。排渣管直径200mm,每日排渣量约120L。

经过沉砂之后的污水经过污水泵房的提升进入核心处理单元——一体化氧化沟。氧化沟出水经过消毒处理后排入附近的东风湖水库。氧化沟剩余污泥经过压榨脱水后外运,不经过浓缩消化等单元,简化了污泥处理流程。

1.3 核心工艺的构筑物介绍

集厌氧、缺氧、好氧、沉淀于一体的氧化沟工艺,因其具备工艺流程短、占地面积少、土建设备投资费用低,工艺抗冲击负荷能力强,脱氮除磷效果好,特殊的水力学设计节约运行动力费等优点被城市污水处理厂广泛采用。贵州省习水县污水处理厂属于贵州省蓝天碧水工程项目,其核心工程采用一体化氧化沟工艺,工程总投资额3500万元,设计处理能力为1.5 万T/d,设计出水水质指标如表1 所示。

表1 设计进、出水水质

工程于2004年9月开工建设,2007年8月中旬开始调试,2008年8月初调试工作结束,转为正常运行。至今出水水质稳定,且各项指标均优于设计标准。

本项处理项目采用厌氧、缺氧、好氧一体化氧化沟工艺如图1所示。

主要构筑物设计参数及作用、实物照片:

1.3.1 格栅、泵房、沉砂池为一期工程所建与其共用。

1.3.2 厌氧区:设计水量Q=15000m3/d,水力停留时间 HRT=1.5hv。厌氧区(共

两格)每格尺寸: L*B*H=12.25m*8.6m*5.5m。

作用: 磷的释放,水解酸化,提高水质可生化性。

1.3.3 缺氧区: 设计水量Q=15000m3/d,水力停留时间HRT=2hv。缺氧区(共

两格)每格尺寸: L*B*H=22.00m*12.25m*5.5m。内部有环形导流装置。 作用:脱氮。

图2 厌氧区、缺氧区实物图

1.3.4 好氧区:设计水量Q=15000m3/d,水力停留时间HRT=10hr,泥龄SRT=15d,负荷F/M=

0.16kgBOD5/kgMLSS·d。

好氧区(共两格)每格尺寸:L*B*H=75.65m*15.25m*4.5m

作用: BOD5 的去除、生物硝化、磷的吸收。

图3 好氧区实物图

1.3.5、侧沟式固液分离沉淀区:

设计水量Q=15000m3/d,表面负荷50m3/m2.d。沉淀区(共两格)每格尺寸:

L*B*H=55.15m*10m*4.5m,出水堰溢流负荷1.6L/(s·m),作用: 固液分离。 图6 侧沟式固液分离沉淀区平面和侧面照片

1.3.6 消毒池与消毒间(二氧化氯发生与添加)

图7 消毒池侧面和平面照片

固液分离之后的水流到消毒池消毒。该厂采用二氧化氯发生器消毒,废水在消毒池中迂回流动。二氧化氯加入是依据一定比例由自动化操作进行的,来自旁边的加氯消毒间。二氧化氯是一种哦绿色气体,沸点11℃,凝固点-59℃,具有与氯一样的臭气,比氯更刺激,毒性更大。二氧化氯易溶于水,在室温、4kpa分压下溶解度为2.9g/L。二氧化氯有广谱杀菌性,除对一般细菌有灭杀作用外,对大肠杆菌、异养菌、铁细菌、硫酸盐还原菌、脊髓灰质炎病毒、肝炎病毒、兰伯士贾第虫胞囊等也有很好的灭菌作用,而且消毒效果受PH的影响不大,PH升高,其灭菌效果越好。另外二氧化氯几乎不和水中的有机物作用生成有害的卤代有机物,效果远高于液氯消毒。

图8 二氧化氯产生间照片

图9 消毒后出水照片

经过二氧化氯消毒之后的处理废水在消毒池后集水渠汇集在一起经过管道输送流出。

1.3.7 污泥处理部分——脱水机房

氧化沟剩余污泥比较稳定,可以不经过浓缩消化等工艺单元二采用直接压榨脱水的方式进行污泥处理。

在脱水机房中,在对剩余污泥进行压榨脱水之前,需要添加絮凝剂,利于脱水。污泥中所含水分可以分为4类:颗粒间间隙水约占70%,毛细结合水约占20%,污泥颗粒表面吸附水和内部结合水约占10%。降低污泥含水率的方法有浓缩法、自然干化法、机械脱水法。氧化沟中活性污泥在系统中的停留时间很长,排出的剩余污泥已趋于稳定,因此省去了污泥消化。

该厂的污泥处理是向污泥中先加入稀释后的阳离子高分子絮凝剂,使污泥颗粒絮凝,比阻降低,改善脱水性能,经过压榨后脱水。污泥脱水的作用是去除污泥中的毛细水和表面吸附水,减小体积。经过脱水处理,污泥含水率能降低至80%以下,

图10 污泥脱水机房外部与内部带式压榨脱水机照片

1.4 脱氮除磷工艺原理及过程阐述

1.4.1 厌氧区: 主要进行磷的释放,水解酸化及生物反硝化。经过预处理的原废水与来自缺氧段的回流污泥同时进入厌氧区,在厌氧(DO=Omg/l)条件下,除磷菌处于压抑状态,可将贮积在菌体内的聚磷分解,将磷酸盐释放到溶液中。在此过程中释放出的能量,一部分供除磷菌在厌氧化压抑环境下存活之用,另一部分能量可供积磷菌主动吸收乙酸以PHB形式贮存在菌体中,并使水解酸化过程得以继续进行,废水中大分子有机物转化为小分子有机物,提高了水质的可生化性,从而使有机物在好氧区能被更彻底去除。同时,来自原废水和回流氧化沟混合液中的硝态氮NO3-N 和亚硝态氮NO2-N,进入厌氧区(或缺氧区)在无氧(DO

1.4.2 缺氧区: 主要功能是通过生物反硝化进行脱氮处理(如前所述)。

1.4.3 好氧区: 混合液从缺氧区进入好氧区—氧化沟中主要进行BOD的去除、磷的吸收及生物硝化等过程。在厌氧条件下,经过有效释放磷酸盐,累积了大量PHB 的除磷菌,进入好氧状态后,将消耗内部贮存的PHB和外源基质产生质子运动力,质子推动力可用来运输磷和产生ATP。从而使除磷菌在好氧环境中贪婪超量的吸收混合液中的磷。在氧化沟中,当污泥龄SRT>8d,溶解氧充足(DO>2.0mg/l)条件下,将生活着两类好氧型微生物即亚硝酸菌和硝酸菌,它们会利用CO3、HCO3 和CO2等无机碳作为碳源,第一步在亚硝酸菌作用下,将氨氮转为亚硝盐;第二步在硝酸菌作用,将亚硝酸盐转化为硝酸盐。同时有机物BOD5 将作为营养物质被活性污泥中的微生物摄取、代谢和利用、从而使污水得以净化。

1.4.4 固液分离区

泥水混合液流入侧沟沉淀区后,在固液分离器作用下,流速迅速降低,泥水混合液在上升过程中,絮状污泥撞到固液分离器,经过几次反复折射后其上升速度逐渐下降直至为零。此时,绝大部分絮状污泥在自身重力作用下开始沉降,在此深度出现了泥水界面,实现泥水分离。清水从上部出水堰流出,沉降到固液分离器下面的大部分活性污泥,被保持一定流速的混合液重新带入氧化沟,继续参与有机物的降解。另一部分增加的活性污泥,将作为剩余污泥经沉淀区底部排泥管,排至脱水机房,进行脱水处理,同时达到除磷的目的。

1.5 调试与运行

从工人师傅的口述以及我查看工作运行日记来看,2007年8月竣工至2008年9月期间,该污水处理厂进行了长达一年的调试工作,在摸索中寻找经验。调试前的准备工作:

(1)对格栅、泵房、曝气沉砂池、厌氧区、缺氧区、好氧区等所有构筑物及相连管道中的石块、木块、金属物等杂物进行彻底的清理工作。确保运

2--

行中的污水泵、污泥泵、脱水机等设备免受其损坏, 而造成不必要的经济损失,影响调试进程。

(2)对所有机电机械设备,构筑物及用电状况进行彻底的安全隐患检查,确保调试工作中人身与设备财产安全。

(3)组织设备厂家、安装公司、监理公司及单位相关人员对所有机电机械设备进行点动试车及联动试车。

活性污泥的快速培养与调试

当时正值汛期(8月),当地气温高雨水多,进水管道为雨污混流因此进入的生活污水被大大的稀释COD、BOD5 负荷偏低,如仅使用生活污水进行活性污泥的培养,营养物质的缺乏将是阻碍活性污泥快速培养成功的主要因素。为补充碳源,该厂特地向附近的习水酒厂运来一些酒厂废水,如仅使用酒厂废水,而COD、BOD5负荷太高,污水中有害成分又对微生物的增殖有一定的抑制和毒害作用。因此,为了实现活性污泥的快速经济培养成功,保证培养质量,决定在活性污泥的培养上,采用选择性进水、接种、培养、驯化同步进行,先间歇闷曝培养,后连续动态培养的方式。取一期氧化沟足够量活性污泥为菌种,于8月中旬开始活性污泥的培养,期间气温在22~29℃。初次,生活污水量与酒厂废水量按9:1的比例注满一体式氧化沟,闷曝24h后排出20%上清液,再补充等量的生活污水与酒厂废水的混合液。随着培养进程的推移,逐渐增大换水量,缩短闷曝时间,提高进水中工业废水的比例。

自此第3天氧化沟活性污泥浓度MLSS=1500mg/L、SV30=15.2%,污泥絮体形状良好,镜检:盾纤虫为优势种群,钟虫已现,但数量较少。此时,开始采用连续动态培养,每天监测COD、PH 值、SS、NH3-N等各项指标及镜检观察。在处理效果良好的情况下,逐步增加进水量,同时提高酒厂废水所占比例,使微生物逐步适应新的环境条件。至第9天时进水量已达到0.65万T/d。氧化沟中MLSS=2500mg/l SV30=16%。SVI=106。镜检:发现新生菌胶团大而密

实,钟虫、累枝虫大量出现,且为优势种群,轮虫数量适中,出水清澈稳定,COD、BOD5、NH3-N、SS 等各项指标已达到设计标准,说明活性污泥已经培养成熟。

当地环保部门提供的验收监测结果见表2。

1.6 运行故障问题与解决

从工作记录中得知,运行到9月2日发现出水悬浮物明显增多,三天后,情况进一步恶化,侧沟沉淀区泥水已经不能分离,活性污泥随出水大量流失。此时,氧化沟内活性污泥浓度MLSS=4500mg/l、SV30=46%、SVI=170、测定SV30时发现活性污泥分层沉降明显,且上层污泥很难沉降,取上层污泥镜检,发现大量真菌(FUNGI)且菌胶团小而松散。

1、原因分析

根据活性污泥各项质量指标及镜检情况, 造成大量活性污泥流失的主要原因是:氧化沟中出

现部分活性污泥膨胀、沉淀区底部流速过快、污泥浓度偏高、固液分离效果不佳。

从运行记录可以看出,这段时期氧化沟中推流器开启台数太多,使沉淀区底部混合液流速过快,而且此时活性污泥浓度(4500mg/l)较设计值

(3500mg/l)明显偏高,致使沉淀区泥位上升,是造成活性污泥流失的又一因素。

2、应对措施

(1)控制污性膨胀的进一步恶化,恢复污泥活性。停止酒厂废水进入,加大进水中生活污水

所占比例,采用活性污泥培养时期的方式,使污泥活性得以恢复。

(2)对不易沉降部分的活性污泥(即已膨胀的活性污泥)从沉淀区出水堰排出。

(3)增大曝气沉砂池的曝气量,使进水中如H2S等易使污泥膨胀的有毒气体,尽可能在曝气

池去除。

(4)将氧化沟活性污泥浓度MLSS控制在1400mg/l左右。

(5)合理开启氧化沟中设备台数,将氧化沟溶解氧控制2mg/l左右,沉淀区底部流速控制在

0.27m/s左右。采取了以上措施,七天后此现象得到控制,污泥活性得到恢复,第十天出水水质: SS=18mg/l、COD =45mg/l、BOD=18.8mg/l、

NH3-N=4.7mg/l。

1.7 结论

(1)实习期间监测结果表明,一体化氧化沟工艺,处理城市污水效果良好,稳定可靠,出水水质某些指标优于《城镇污水处理厂污染物排放标准》(GB18918-2002)一级标准中的B标准。COD去除率90.4%、BOD去除率93.2%、NH3-N去除率86.5%、SS去除率91.3%。

(2)设有厌氧、缺氧和好氧区,利用不同的微生物特性提高了废水可生化性,同时具备了脱氮除磷的功效。该厂每年对污染物削减量为:BOD5 876吨、COD 1205吨、SS 1260吨、NH3-N 82吨、TP17吨,对习水县实现污染物

减排的目标有着重要贡献。

(3)一体化氧化沟与其他污水生物处理技术相比,工艺流程短,减少了构筑物和设备,节约投资费用,降低机械事故率,有利于污水处理设施的维护和管理。

(4)特殊的水力学设计实现了污泥自动回流,不设二次污泥回流泵站,节约运行动力费。由于二沉淀与氧化沟合建,侧沟沉淀区底部流速,影响着活性污泥的沉降效果,决定着泥位的高低,也就直接影响出水中悬浮物的多少。而固液分离器,就是起着降低水流速度,实现固液分离的作用。因此,一体化氧化沟对固液分离器的技术性能有着更严格要求。

(5)通过与工人师傅的交流和翻阅运行记录本,总结出了污泥培养与系统启动运行的一些经验,为自己将来的污水厂管理工作积累了宝贵的财富。

1.8 存在的问题与今后发展趋势

问题:

(1) 污水处理厂建设资金短缺,运行经费有时候不能到位;

(2) 进口设备虽好,可是一旦损坏,其维修是个问题。建议加大设备

备件的开发力度;

(3) 污水处理工艺的选择有一阵风的现象,常不结合本地区实际情况

而是盲目选择热门工艺;

(4) 再生水买没有得到充分利用;

(5) 普遍缺少专门的高级人才。尤其是小型污水厂内缺少环境工程类

专业的技术人员;

今后的发展趋势:

(1) 经济发展与污水处理事业协调发展;

(2) 政府加大对环保产业的支持力度,多方筹资加速污水处理厂的建

设,以最短的时间控制、治理已造成污染的水环境;

(3) 改变污水处理行业的运营机制,由事业型向企业经营型转变;

(4) 环保要从娃娃抓起,提高全民的水环境忧患意识。

2.建筑给水排水工程——习水县人民医院门诊综合大楼

2.1 习水县人民医院简介

习水县人民医院是集医疗、教学、科研、康复、预防保健、业务指导为一体的县级综合性医院,承担全县近70万人民的防病治病任务。属“国家二级乙等医院”,并被评为“爱婴医院”、“贵州省高等医药院校教学实习医院”、“贵州省模范职工之家”、“贵州省院务公开先进单位”、“贵州省三八红旗先进集体”、“遵义市市级文明单位”、“遵义市医疗质量管理先进单位”。现有高级职称20人,中级职称70人,一线医务人员230人,共有员工260。分为门内科、普外科、病理科、神经外科、儿科、五官科、中医科、放射科、骨科、皮肤科、急诊科、生殖泌尿科、妇产科、血库、医教科等31个科室单位。能进行血液透析、多普勒超声诊断、CT、脑电图、震荡碎石等检查。

2.2 习水县人民医院建筑物概况

辖门诊综合楼(5层砖混)一栋,综合办公大楼(12层梁柱框架结构)一栋,住院1部(5层砖混)住院2部(6层梁柱框架结构)各一栋,篮球场一个,锅炉房1个、食堂一个、老年活动中心1个、停车场1个(面积400m2)。

门诊综合楼位于大门右方,坐北朝南,占地1200m2,总高21.2m。一层层高4.2m,其余各层层高3.4m。门诊一楼:西药房、挂号室、缴费室、护士站、普内科、专家内科、验血验尿化验室,二楼设有中药房、中医科、五官科、脑电图室、医保收费站,三楼设有皮肤科、神经内科;四楼设有儿科、放射科,五楼设有生殖泌尿科、医教科、中心血库、CT、彩超等辅助诊疗室。日门诊量约600人。每层楼有一东一西两处公用厕所,其中男卫生间小便器4个,大便器4个,女卫生间大便器4个。

2.3 医院建筑给水排水的特点

随着现代医学科学的迅速发展,新技术、新医疗设备层出不穷,从而与之相

符的现代化医疗建筑———医院,也面临着新的设计理念和新技术的运用。无论从医院建筑物功能、其所处的环境,还是医院建筑设备及装备系统,要求均愈来愈高。因为它不仅是保障日常工作生活的需要,而且与救治病人、促进康复、避免致残、挽救生命紧密相关。作为给排水专业的设计不仅需要满足医院建筑中设备上不同功能的要求,而且必须安全可靠。

(1)各门急诊科室,尤其是传染科病房各诊室、治疗室、洗涤盆都设非手动水咀。可采用肘式、膝式或脚踏式开关。如使用脚踏式开关一定要使用防渗漏的产品,以免使用处地面经常潮湿,使病员、医务人员滑倒,发生事故。

(2)医院的设备及装备系统内容繁多,功能特殊,要求很高。除了要求保证持续供给充分符合质量标准的用水外,更需要根据不同的医疗仪器以及不同科室对水质、水压、水温的要求,分门别类设置水处理系统和对系统进行增减压。

(3)医院的许多科室,尤其是检验室、化验室、放射科等科室中的酸洗池、消毒池、洗片池等下水管道应采用耐腐的PVC-U排水塑料管。

(4)对各类污、废水必须严格按国家有关排放标准分门别类,用不同的处理工艺进行针对性地处置和处理。达到无害化后才能排入市政管道。

2.4 医院建筑给排水系统设计心得

医院的设备及装备系统内容繁多,功能特殊,要求很高。除了要求保证持续供给充分符合质量标准的用水外,更需要根据不同的医疗仪器以及不同科室对水质、水压、水温的要求,分门别类设置水处理系统和对系统进行增减压。

门急诊、医技楼往往由于医疗功能需要,给排水横、立管布置较为散乱,

较多的明露在室内,有时加之暖通专业的管道,使房间内明露的管道过多,既不雅观,又影响卫生。这就要求在工程设计过程中,应充分利用不同的结构形式进行合理布置,根据功能需要尽量使各种管道隐蔽布置,在不影响使用的前提下,注意美观得体。

传统的医院热水供应系统中,人们基本上采用容积式热交换器。主要是考虑所提供蒸汽量与热水供应最大值之间差值的调节量,减小了蒸汽锅炉设计量,减少了锅炉房占地面积,节约了一次性投资。然而现在人们对水质要求愈来愈高,尤其是生活热水中发现军团菌致病的实例,引起人们的高度重视。主要是因为在30℃~55℃水中最容易繁殖军团菌,为此世界卫生组织(WHO)推荐:“热水应在60℃以上储存,并至少在50℃以上循环。如某些使用者,需要将水龙头水温降至40℃或50℃左右,这时可以使用调温混合阀来实现。

三 集中实习篇

1.听专家的报告

1.1 给水工程设计的讲座

3月9号上午8点半,在城环学院4楼多媒体视频教室内,来自西南市政设计研究院重庆分院给排水主任设计师马刚高级工程师为我们奉献了一场精彩的“给水工程设计”讲座。

马高工是我院82级杰出校友,先后承担了重庆市、四川省等多地的重要给水工程设计项目,在净水厂设计、给水管网设计等方面很有特色,经验丰富。讲座一开始,马高工概括起来说“给排水专业的东西很杂,很乱,作为一个公用设备工程师,需要知道很多的东西,很多书本上都没有的东西,需要我们在工作中不断总结,才能轻车熟路上手。然后他就结合自身工作实例“重庆市南溪县3万吨净水厂与配套管网设计工程”向我们讲述。

马工讲述了该设计中最重要的是要先熟悉两个规范:《室外给水设计规范》GB50013-2006和《生活饮用水卫生标准》GB5747-2006,对于重庆地区,由于夏季有高浊度水,最高浊度可达1万多NTU,所以需要采取必要的加强工艺,西南地区最常用的饮用水处理工艺是两级絮凝沉淀或者两级沉淀,即预沉、絮凝沉淀、过滤、消毒、出水,必要时可以在预沉池也设置加药系统。两个沉淀池之间设置超越管,当在常浊度进水条件下,来水就超越预沉池直接进入二级絮凝沉淀池,节省药耗和能耗。由于环境的破坏,水源水为微污染水时,要采取必要的加强措施。为去除BOD5和NH3-N,可以采取预氧化(O3、KMnO4),也可以采用后续深度处理:活性炭滤池、膜反应器。

新标准中的饮用水水质指标由原标准的35项增至106项,增加了71项。其中,微生物指标由2项增至6项;饮用水消毒剂指标由1项增至4项;毒理指标中无机化合物由10项增至21项;毒理指标中有机化合物由5项增至53项;感官性状和一般理化指标由15项增至20项;放射性指标仍为2项。现在的饮用水处理程度还没有完全达到《生活饮用水卫生标准》GB5747-2006的106项指标的要求,就是传统工艺不能达标。因此现在净水厂的设计需要增加深度处理的环节,这就为我们科研与设计工作者提出了更高的要求。

对于给水管网设计,马工针对重庆山地地形的特征,提出分压分级供水,避免整个管网压力过高、爆管事件频发,在设计时候不追求100%的管网都满足平差要求,只要90~95%的满足就可以了,对与难以满足部分,采用额外供水、单独供水的方式解决。

规范要求二沉池出水低于10NTU,马供建议最好低于5 NTU。适当降低二沉池负荷,增大占地面积,提高出水水质标准,可以使后续滤池的工作周期更长,减少反冲洗水耗量。从长远看,是值得的。

1.2 建筑给水排水工程设计的讲座

今天上午8点4分,在A区研究生院606教室,来自重庆市设计院的教授级高级工程师汤浩校友为我们讲解关于“建筑给排水设计”的设计经验。

汤前辈是我系63年毕业的元老级、重量级、高级别的设计师,从事给排水设计40多年,可谓资历深厚,经验丰富。他的报告分为5个部分:给排水专业设计范围与内容、民用建筑给排水设计步骤、国内外高层建筑情况、高层建筑消防、自动喷水灭火系统。

本专业设计范围包含市政工程与建筑工程,对于市政工程,我们主要负责其中城镇给排水管网、道路排水、净水厂、污水处理厂及部分环保工程的设计,对于建筑工程,含工业与民用建筑。

在设计之前,需要搜集相关资料,弄清楚水源水质与水压情况,以此选择供水方案,同时要和电气、暖通、结构等专业协调,彼此提供建议和帮助。设计中常分为可研、初设、施工图设计三个阶段,我们需要熟悉相关规范的要求,如《建筑给水排水设计规范》GB 50015-2003、《自动喷水灭火系统设计规范》GB 50084-2001等。通过水压等确定方案、之后可以计算水量、确定管径、选设备、出图。初设经过上级主管部门批复后,才可以做施工图设计,出图需要经过建委委托的审图中心的专家审核,各设计院之间彼此提意见或建议。审核通过后就可以进入施工阶段。

之后,汤前辈又给我们介绍了几种生活给水系统的特点,对于减压阀给水系统,他建议在减压阀之前设置一过滤器,预防阀中活塞淤堵而失效。

1.3 排水工程设计的讲座

今天上午9时,来自重庆市市政设计研究院的副院长、我系82级杰出校友程吉建高级工程师为我们讲述“城市排水工程设计”。程工主要结合自己所做的机场排水系统设计为我们讲述,山地城市排水系统的特点之一是管道埋深较平原城市深,这样一方面违背规范的要求,二来检修很不便,还有

安全隐患(如检查井)。因此需要设置必要的消能措施(如跌水消能井),控制埋深,降低施工难度,也节省造价。

雨水排水系统设计中有一个很重要的参数就是暴雨重现期,对于不重要的小城镇和重要的大城市,暴雨重现期的大小不一。重现期数值越大、水量越大、设计管径越大,造价越高。由于地方差异,每个地方的暴雨强度和周期不一,因此需要对其分别对待,同时兼顾城市的重要程度、人口等因素。

1.4 给排水规划的讲座

今天上午8点半,来自重庆市规划设计研究院的高级工程师、我系90级校友孙黎和我们一起探讨了给水排水专业在城市规划领域中的应用。孙师姐一来就给大家一种很亲切的感觉,她准备充分、逻辑严密、层次清晰。她的讲座包含了8个方面:城市规划编制的层次、水资源承载力在城市规划中的应用、山地城市给水排水规划的特点、城乡统筹下的给水排水、与生态环境保护的结合、规划的近、远期结合的问题、给水排水规划的编制、其他。

城市规划是对一定时期内城市的经济和社会发展、土地利用、空间布局以及各项建设的综合部署、具体安排和实施管理,也是各级政府统筹安排城乡发展建设空间布局,保护生态和自然环境,合理利用自然资源,维护社会公正与公平的重要依据,具有重要公共政策的属性。城市规划分为总体规划、分区规划、详细规划。

水资源承载力是—定的区域内,在一定的生活水平和生态环境质量下,天然水资源的可供水量能够支持人口、环境与经济协调发展的能力或限度。水资源承载力是影响城市规模的一项重要指标。

山地城市给水规划要求:

(1)水源点的选取与取水成本的综合考虑;

(2)水厂选址与地面标高的关系,不宜过低;

(3)山地城市通常存在以不同地形标高而采用分级供水形式,应注意

对地形的分析,采用合理、经济的分级数,以及合理布局加压泵站。

(4) 可在不影响城市建设用地的前提下,充分利用地形布局高位调节

水池;

(5) 管网布局以环状与枝状相结合

山地城市排水规划要求:

(1)按自然地形划分流域分水线并进行分析;

(2)按流域划分与相对集中原则相结合布局污水处理厂,并结合城市建设用地布局和人口密度分布情况,在合理性、经济性、技术性和可行性方面进行多方案比较;

(3)在经济性方面还应注意建设投资与运行成本的比较;

(4)雨水系统规划和防洪规划的结合问题;

(5)尽可能保留天然水系、自然冲沟,确属需要并在经过论证和水利等相关部门同意后才可进行人工渠化、改造,但同时应考虑排洪管道;

(6)对暴雨强度公式中的重现期,可在同一系统中采用同一重现期或不同重现期,干管和较重要地区采用3-5年,一般地区采用1-3年,特别重要地区可采用5-10年、20年或以上。

城乡统筹中给水规划特点

(1)从区域和水资源角度,为城乡发展提供强有力的水源保障支撑;

(2)大力强调城乡饮用水源保护;

(3)注重供水工程安全;

(4)加快乡村地区供水设施建设 ;

(5)加强区域协调发展;

(6)节水型社会建设 ;

城乡统筹中排水规划特点

(1)体现城乡统筹规划原则 ,注重环境保护、安全;

(2)加快中、小城镇生活污水处理建设;

(3)加强农村水污染防治及污水处理建设;

(4)注重工业废水处理的控制;

(5)城市排涝规划;

1.5 给排水消防工程的讲座

今天上午8点半,重庆市公安消防总队建审处的我校95级校友、邹俊少校工程师为我们讲述“建筑消防给水系统”。邹工身穿警服,器宇轩昂。从事建筑审查10年以来,累计审核工程1500个以上,在建筑消防方面有丰富的经验和深刻的感悟。

消防灭火系统根据使用灭火剂的种类和灭火方式可分为:消火栓给水系统、自动喷水灭火系统、

其他使用非水灭火剂的固定灭火系统:如CO2灭火系统、卤代烷替代物灭火系统。

以使用广泛的消火栓灭火系统为例,其组成包含:消火栓设备(水枪、水带和消火栓组成,均安装于消火栓箱内)。水泵接合器、消防管道、消防水池、消防水箱。其消防给水方式可分为:由室外给水管网直接供水的消防给水方式、设水箱的消火栓给水方式、设水泵、水箱的消火栓给水方式、设水池、水泵的消火栓给水方式、设水泵、水池、水箱的消火栓给水方式、分区供水方式。

他接着介绍了水枪充实水柱长度、消火栓布置、消防水池容积、消防水箱的最小消防贮水量等专业术语的意义。

消火栓灭火系统介绍结束后,邹工向我们介绍了自动喷水灭火系统,其由喷头、报警阀、水流报警装置、延迟器、火灾探测器等组成,在高级娱乐场所、人流密集的场所应用广泛。

最后,邹工谈了几点他多年审图中的经验,诸如室外消防管网应形成环

30

状,且应尽可能形成“真环”,确保管网的供水可靠性等的建议,对我们很有帮助。同时,他还勉励我们踏实工作,严谨设计,安全第一,质量重于泰山。

2.参观西南医院建筑给水排水系统

由于时间原因和指导教师的进度安排等情况,该项将在毕业设计期间以本小组为单位进行。拟定指导人为本专业90级校友,重庆大学建筑设计研究院的赵赢工程师,拟参观学习西南医院的建筑给水排水系统,此处不多做作深究。

四 实习收获与心得体会

很快,三周的实习时间就过去了。在这三周的实习时间我学到了很多课本上不可能学到的知识。现就实习情况做如下总结:

通过实习,我知道了学习的重点,增加了对本专业的整体性认识,提高了自己解决实际问题的能力;通过实习,提高了自己的识图能力,对施工图纸的认识,有了更大的跨越;通过实习,增强了理论联系实际的能力,弥补了课堂上的不足;通过实习,为毕设做了较好的巩固,也为自己毕业后走上社会工作奠定了一定的基础;通过实习,培养了我吃苦耐劳的精神,更学到了如何与现场施工人员、技术人员沟通的技巧。

我们这次实习内容相当丰富,增强了我的工程意识和创新意识,对自己专业的就业方向和就业前景有了比较全面的认识,能够对将来的择业提供很多有益的参考。不管是在污水处理厂,还是在学校听专家的报告,都极大的开阔了眼界,使自己对专业的认识有前所未有的提高。

参看文献:

[1]王洪臣, 等. 城市污水处理厂———运行控制维护管理北京: 科学出版社. 1997.11

[2]徐亚同、史家辉, 等. 污染控制微生物工程, 北京: 化学工业出版社、环境科学与工程出版中心出版发行. 2001.05

31

[3]胡家骏、周群英, 等. 环境工程微生物学, 高等教育出版社

[4](美) 格雷迪( Grady, jr,C.P.L) ,(美) 戴吉尔( Dargger, G.T.) ,(美) 林( Lrm, H.C) 著. 废水生物处理: 改编和扩充: 第二版/ 张锡辉, 刘勇弟译北京: 化学工业出版社会. 2002.12

[5]李军, 杨秀山, 彭永臻. 生物与水处理工程. 北京: 化学工业出版社会性. 2002.09

[6] GB50015-2003建筑给水排水设计规范[S]

[7] 鲁雪利.浅谈建筑给排水中噪音问题及防治. 甘肃科技[J],2006 年 11 期198-199

[8] 申永平.UPVC排水管在多层住宅中的应用问题探讨.科技资讯[J],2006年第5期:105

[9] GB50045-95高层民用建筑设计防火规范[S],2005

[10] 王增长.建筑给水排水工程[M].高等教育出版社

[11] 张智、蒋绍阶、张勤. 给排水科学与工程专业毕业设计指南[M]第二版.中国水利水电出版社2008

32

目 录

一 毕业实习绪论...........................................................................................................................2

1.实习目的 .............................................................................................................................2

2.实习要求 .............................................................................................................................2

3.实习内容...........................................................................................................................3

3.1. 净水厂的实习 .........................................................................................................................3

3.2. 污水处理厂的实习..................................................................................................................4

3.3. 建筑给排水实习 .....................................................................................................................5

3.4 专业参观.................................................................................................................................6

3.5 听专家做有关设计报告............................................................................................................6

4.实习地点 .............................................................................................................................6

5.指导教师 .............................................................................................................................7

二 分散实习篇 ..............................................................................................................................7

1.排水工程——习水县污水处理厂 ..........................................................................................7

1.1 习水县污水处理厂概况............................................................................................................7

1.2 习水县污水处理厂工艺流程.....................................................................................................8

1.3 核心工艺的构筑物介绍.......................................................................................................... 10

1.4 脱氮除磷工艺原理及过程阐述 ............................................................................................... 16

1.5 调试与运行 ........................................................................................................................... 17

1.6 运行故障问题与解决 ............................................................................................................. 19

1.7 结论...................................................................................................................................... 20

1.8 存在的问题与今后发展趋势................................................................................................... 21

2.建筑给水排水工程——习水县人民医院门诊综合大楼 ........................................................ 22

2.1 习水县人民医院简介 ............................................................................................................. 22

2.2 习水县人民医院建筑物概况................................................................................................... 23

2.3 医院建筑给水排水的特点 ...................................................................................................... 23

2.4 医院建筑给排水系统设计心得 ............................................................................................... 24

三 集中实习篇 ............................................................................................................................ 25

1.听专家的报告 .................................................................................................................... 25

1.1 给水工程设计的讲座 ............................................................................................................. 25

1.2 建筑给水排水工程设计的讲座 ............................................................................................... 27

1.3 排水工程设计的讲座 ............................................................................................................. 27

1.4 给排水规划的讲座................................................................................................................. 28

1.5 给排水消防工程的讲座.......................................................................................................... 30

2.参观西南医院建筑给水排水系统 ........................................................................................ 31

四 实习收获与心得体会 .............................................................................................................. 31 参看文献: ................................................................................................................................. 31

一 毕业实习绪论

1.实习目的

学生参加实习是理论学习和时间锻炼相结合的重要机会,是提高政治思想水平和业务素质的重要环节。

给排水工程实习是给排水专业学生必须完成的课程之一。通过实习,可以是学生了解社会,接触实际,增强群众观点,劳动观念,和社会主义的事业心,责任感,提高政治思想觉悟;通过学习,可以获得给谁排水的世界只是,巩固所学理论,培养初步的实际工作能力和专业技能,使学校教育与社会教育的更好的结合,为毕业设计做好准备。

毕业实习是《给水排水工程》专业学生的主要教学环节之一。其目的与要求如下:

(1) 熟悉和掌握室外给水排水工程,建筑给水排水工程的设计内容、步骤与方法;

(2) 了解水厂、污水处理厂和建筑给水排水等方面的运转管理经验;

(3) 了解工程技术人员和工人师傅在科研、技术革新方面的成就,学习他们的积极性和创造精神,从而提高学生学习的积极性与自觉性;

(4) 扩大学生的专业知识范围,加深和巩固所学的理论知识。

通过参观学习、资料查询以及专题讲座等实习内容,收集与毕业设计(论文)题目有关的资料,为毕业设计(论文)作好准备。

2.实习要求

(1) 学生要重视向实际学习,向工人学习,多问多记,记号笔记,写好实习报告。

(2) 严格遵守各项规章制度。

① 学生往返实习场所应该集体行动,不得无故擅自行动,确有原因者,

必学向知道老师说明并应该征得知道老师的同意。

②学生实习期间不准请假,特殊情况需持证明经过知道老师的批准,否则按旷课处理。

③严格遵守工厂的规章制度和操作规程,主意安全,遵守保密制度,爱护公共财务。

④学生要注意路途安全,不得打架斗殴。

通过本课程的学习,熟悉和掌握室外给水排水工程,建筑给水排水工程的设计内容、步骤与方法;了解室外给水排水工程,建筑给水排水工程在实际应用中所产生的问题以及解决问题的方法;扩大学生的专业知识范围,加深和巩固所学的理论知识;收集与毕业设计(论文)题目有关的资料,为毕业设计(论文)作好准备。

3.实习内容

本次的实习中共分为三部分:给水工程、排水工程、建筑给排水工程。

3.1. 净水厂的实习

水厂实习按给水工艺流程分取水、混凝沉淀、过滤消毒、送水泵站四个部分,深入了解,重点解剖。水厂实习的内容和要求如下:

(1)熟悉了解水厂布置及工艺流程;

(2)熟悉了解水源情况(水源水量、水位、流速及水质情况);取水构筑物的型式与构造,操作管理的内容和方法;取水泵站的布置和附属设备,水泵的操作规程,运行中存在的问题。

(3)熟悉了解混凝剂情况;混凝沉淀,澄清、气浮等构筑物的型式、构造、基本设计参数以及运行管理内容、方法和经验。

(4) 熟悉了解过滤和消毒设备的型式、构造、工作过程、基本设计参数以及运行管理内容、方法和经验。

(5) 熟悉了解送水泵站的工作特点、水泵布置和调度方式、水泵启动、停车的操作程序及注意事项,水泵运行记录,泵站附属设备,泵站供电方式及设备。

(6) 了解水厂自动化设施及运行情况。

(7) 了解水厂化验室的任务,化验项目和方法;主要化验设备情况。

(8) 了解水厂组织管理及水厂运行的技术经济指标,包括人员编制,漏失水量和水厂自用水量,每吨水的电耗、制水成本和水价。

3.2. 污水处理厂的实习

污水处理厂实习分为泵房和空压机房、曝气池和沉淀池,化验室等三个部分,深入了解,重点解剖。污水处理厂实习内容如下:

(1)熟悉和了解污水厂布置,污水处理和污泥处置的工艺流程,处理水量,进出水水质和处理效率;

(2)熟悉了解各项构筑物的形式和构造,基本设计参数,运行方式和运行管理的各项控制指标。

对于格栅有:格栅间距、栅间流速、截留污物量和污物消除方式;

对于沉砂池有:水流速度、停留时间、沉砂量和排砂方式;

对于沉淀池(初次、二次)有:水流速度(上升流速、水平流速和板间流速)、停留时间、表面负荷率、出流堰的单宽流量、排泥方式和排泥间隔时间(或连续排泥);

对于曝气池有:污泥负荷率、曝气时间、混合液污泥浓度、污泥指数、污泥回流比和回流污泥浓度等。

(3)熟悉和了解污水泵房、空压机房的操作规程、工作情况、自动化控制技术及有关指标;

(4)熟悉和了解化验室工作情况,化验项目及方法,各主要项目的分析数据,主要化验设备,化验室的总体布置情况;

(5)了解污水厂的组织管理及运行的各项技术经济指标,包括人员编制、电耗、污水处理成本等。

3.3. 建筑给排水实习

(1)全面地、系统地了解建筑给水排水工程的设计程序,各设计阶段要求的设计内容和深度,设计方案的比较和选择,图纸的表达方法以及说明书编制等。

(2)了解建筑性质、用途、体积、层高、耐火等级、结构情况、使用人数、卫生器具和用水设备布置情况,电气和暖通专业管线布置情况,以及气候条件。

(3)了解用户、建筑对给水,消防和热水供应的要求(如水量、水质、水压、水温等),对供水安全程度的要求,以及对环境安静程度和建筑美观等的要求。

(4)了解工程的水源情况,室外的市政给水管道设置情况、以及管径、水压、水温和供水的可靠性。

(5)了解污、废水的排放条件,市政排水管网对建筑排水的处理要求,室外排水体制,室外污废水和雨水管道设置情况。

(6)重点了解该高层建筑给水、消防及热水供应系统的组成,供水方式,设备及管道的平面布置,系统竖向分区情况。

(7)重点了解该建筑冷、热水用水量标准,生活及消防设计流量的确定,空调用水量,热水设计水温的确定,高位水箱,分区水箱及地面贮水池容积的确定。

(8)重点了解该建筑热水供应系统热源的选择,水的加热方法、加热设备的选择。锅炉、加热器、水泵及主要附属设备的型号、数量及其设备的布置情况。

(9)重点了解该建筑的排水系统体制,排水系统的组成,排水方式,高层建筑排水通气系统的设置情况。

(10)了解空调冷却用水供水方式,冷却设备的型号、性能、设置情况。

(11)了解高层建筑给排水工程有关保温、防腐、防震及防噪音技术措施。

(12)收集工程采用的新技术、新设备和新材料。设计和施工的先进经验,设计和使用中存在的问题。

3.4 专业参观

参观目的:使学生见到更多类型的给排水工程设施,扩大学生的专业知识面。

参观安排:可在学生分散实习或集中实习进行。

给水参观内容:城市给水处理工程、增压泵站、新型净水构筑物、离子交换移动床和固定床软化设备、电渗析除盐、各种填料冷却塔等。

排水参观内容:城市污水处理工程、中途泵站、雨水泵站、化纤废水处理、印染废水处理、电镀废水处理、含有废水处理、肉联厂废水处理、食品加工厂废水处理等。

建筑给水排水参观内容:高层建筑中的宾馆、大型公共建筑物、住宅等。 参观期间:学生应认真记录技术人员、工人师傅介绍的参观内容,绘制必要的草图,并及时整理参观笔记。

3.5 听专家做有关设计报告

4.实习地点

4.1 贵州省习水县供水公司污水处理厂

4.2 贵州省习水县人民医院

4.3 西南医院

5.指导教师

重庆大学给水排水工程系主任 张勤 教授

贵州省习水县供水公司污水处理厂生产科主任 李健 助理工程师

贵州省习水县人民医院门诊部主任 张勇 副主任医师

二 分散实习篇

1.排水工程——习水县污水处理厂

1.1 习水县污水处理厂概况

习水县污水处理厂现隶属习水县供水公司,接受习水县环境保护局、习水县环境监察大队的监督和指导。现有员工19人,具有中级职称的3人,具有初级职称的8人,维修工6人,门卫1人,后勤1人。该厂始建于2004年9月,2007年8月竣工,设计处理规模是1.5万m3/日。建设单位:习水县天生桥污水处理工程有限公司;设计单位:贵州省建筑设计研究院;监理单位:贵阳科力建设工程监理有限公司;施工单位:水城钢铁(集团)赛得建设有限公司;

该污水处理厂主要处理来自主城东皇镇东城区以及西城区的生活污水,处理后排入东风湖水库。核心工艺是一体化氧化沟技术,进出水都有在线水质水量的监控措施。由于城市排水管网还不完善,故对于部分老城区,尤其是菜市场至小龙口段的生活污水未能收集进入管网,因此目前实际污水处理量一般为4400~4800m3/d,夏季可达6000m3/d。处理标准执行一级B标。剩余污泥经压榨脱水后直接外运。

1.2 习水县污水处理厂工艺流程

习水县污水处理厂位于习水县县城所在地东皇镇以西约2.5公里的银杏村,占地1.8公顷,服务人口10万人,海拔1120m,常年最低气温-3°,最高气温32°,平均气温14.8°,夏无酷暑冬无严寒,主导风向为西南风,地质以砂岩为主,地基承载力较好,无滑坡无坍塌。该厂包含预处理站和二级处理厂两部分,其中预处理站位于六角洞村,二级处理与污泥处理部分位于该厂本部。该厂处理污水执行一级B标排放标准。

位于六角洞的预处理站接受来自主城的生活污水,设有粗格栅、提升泵房和细格栅,之后压力管输送至污水处理厂。

粗格栅一用一备,采用HGS-1300回转弧形格栅除污机,栅前流速

0.8m/s,栅条间距为25mm,总宽1.0m,功率0.55KW。每日的栅渣量为28kg,机械清渣。

提升泵房占地78m2,包含配电间和操作间、机房,人员配置是2人,负责机房的正常运转和设备维修。泵两用一备,采用100WDL-15,设计Q130m3/h,扬程为14m,转速达到1500r/min,电机型号Y132M-4B5,功率7.5KW,效率66%,重量300Kg。

细格栅一用一备,采用型号HG-1200回转弧形格栅除污机,栅前流速1.0m/s,栅条间距为10mm,总宽1.0m,功率0.45KW,每日的栅渣量为50kg,机械清渣。

细格栅之后,污水由DN600的两根压力干管输送至污水处理厂,钢管,长度1.5km。

压力管来水进入污水处理厂的辐流式沉砂池。

辐流沉砂池设计沉砂时间1min,设计水力表面负荷为150m3/m2·h,有效水深2.0m,池径6.0m,出水堰负荷2.8L/(s·m),机械排泥,排泥机械旋转速度1r/h。排渣管直径200mm,每日排渣量约120L。

经过沉砂之后的污水经过污水泵房的提升进入核心处理单元——一体化氧化沟。氧化沟出水经过消毒处理后排入附近的东风湖水库。氧化沟剩余污泥经过压榨脱水后外运,不经过浓缩消化等单元,简化了污泥处理流程。

1.3 核心工艺的构筑物介绍

集厌氧、缺氧、好氧、沉淀于一体的氧化沟工艺,因其具备工艺流程短、占地面积少、土建设备投资费用低,工艺抗冲击负荷能力强,脱氮除磷效果好,特殊的水力学设计节约运行动力费等优点被城市污水处理厂广泛采用。贵州省习水县污水处理厂属于贵州省蓝天碧水工程项目,其核心工程采用一体化氧化沟工艺,工程总投资额3500万元,设计处理能力为1.5 万T/d,设计出水水质指标如表1 所示。

表1 设计进、出水水质

工程于2004年9月开工建设,2007年8月中旬开始调试,2008年8月初调试工作结束,转为正常运行。至今出水水质稳定,且各项指标均优于设计标准。

本项处理项目采用厌氧、缺氧、好氧一体化氧化沟工艺如图1所示。

主要构筑物设计参数及作用、实物照片:

1.3.1 格栅、泵房、沉砂池为一期工程所建与其共用。

1.3.2 厌氧区:设计水量Q=15000m3/d,水力停留时间 HRT=1.5hv。厌氧区(共

两格)每格尺寸: L*B*H=12.25m*8.6m*5.5m。

作用: 磷的释放,水解酸化,提高水质可生化性。

1.3.3 缺氧区: 设计水量Q=15000m3/d,水力停留时间HRT=2hv。缺氧区(共

两格)每格尺寸: L*B*H=22.00m*12.25m*5.5m。内部有环形导流装置。 作用:脱氮。

图2 厌氧区、缺氧区实物图

1.3.4 好氧区:设计水量Q=15000m3/d,水力停留时间HRT=10hr,泥龄SRT=15d,负荷F/M=

0.16kgBOD5/kgMLSS·d。

好氧区(共两格)每格尺寸:L*B*H=75.65m*15.25m*4.5m

作用: BOD5 的去除、生物硝化、磷的吸收。

图3 好氧区实物图

1.3.5、侧沟式固液分离沉淀区:

设计水量Q=15000m3/d,表面负荷50m3/m2.d。沉淀区(共两格)每格尺寸:

L*B*H=55.15m*10m*4.5m,出水堰溢流负荷1.6L/(s·m),作用: 固液分离。 图6 侧沟式固液分离沉淀区平面和侧面照片

1.3.6 消毒池与消毒间(二氧化氯发生与添加)

图7 消毒池侧面和平面照片

固液分离之后的水流到消毒池消毒。该厂采用二氧化氯发生器消毒,废水在消毒池中迂回流动。二氧化氯加入是依据一定比例由自动化操作进行的,来自旁边的加氯消毒间。二氧化氯是一种哦绿色气体,沸点11℃,凝固点-59℃,具有与氯一样的臭气,比氯更刺激,毒性更大。二氧化氯易溶于水,在室温、4kpa分压下溶解度为2.9g/L。二氧化氯有广谱杀菌性,除对一般细菌有灭杀作用外,对大肠杆菌、异养菌、铁细菌、硫酸盐还原菌、脊髓灰质炎病毒、肝炎病毒、兰伯士贾第虫胞囊等也有很好的灭菌作用,而且消毒效果受PH的影响不大,PH升高,其灭菌效果越好。另外二氧化氯几乎不和水中的有机物作用生成有害的卤代有机物,效果远高于液氯消毒。

图8 二氧化氯产生间照片

图9 消毒后出水照片

经过二氧化氯消毒之后的处理废水在消毒池后集水渠汇集在一起经过管道输送流出。

1.3.7 污泥处理部分——脱水机房

氧化沟剩余污泥比较稳定,可以不经过浓缩消化等工艺单元二采用直接压榨脱水的方式进行污泥处理。

在脱水机房中,在对剩余污泥进行压榨脱水之前,需要添加絮凝剂,利于脱水。污泥中所含水分可以分为4类:颗粒间间隙水约占70%,毛细结合水约占20%,污泥颗粒表面吸附水和内部结合水约占10%。降低污泥含水率的方法有浓缩法、自然干化法、机械脱水法。氧化沟中活性污泥在系统中的停留时间很长,排出的剩余污泥已趋于稳定,因此省去了污泥消化。

该厂的污泥处理是向污泥中先加入稀释后的阳离子高分子絮凝剂,使污泥颗粒絮凝,比阻降低,改善脱水性能,经过压榨后脱水。污泥脱水的作用是去除污泥中的毛细水和表面吸附水,减小体积。经过脱水处理,污泥含水率能降低至80%以下,

图10 污泥脱水机房外部与内部带式压榨脱水机照片

1.4 脱氮除磷工艺原理及过程阐述

1.4.1 厌氧区: 主要进行磷的释放,水解酸化及生物反硝化。经过预处理的原废水与来自缺氧段的回流污泥同时进入厌氧区,在厌氧(DO=Omg/l)条件下,除磷菌处于压抑状态,可将贮积在菌体内的聚磷分解,将磷酸盐释放到溶液中。在此过程中释放出的能量,一部分供除磷菌在厌氧化压抑环境下存活之用,另一部分能量可供积磷菌主动吸收乙酸以PHB形式贮存在菌体中,并使水解酸化过程得以继续进行,废水中大分子有机物转化为小分子有机物,提高了水质的可生化性,从而使有机物在好氧区能被更彻底去除。同时,来自原废水和回流氧化沟混合液中的硝态氮NO3-N 和亚硝态氮NO2-N,进入厌氧区(或缺氧区)在无氧(DO

1.4.2 缺氧区: 主要功能是通过生物反硝化进行脱氮处理(如前所述)。

1.4.3 好氧区: 混合液从缺氧区进入好氧区—氧化沟中主要进行BOD的去除、磷的吸收及生物硝化等过程。在厌氧条件下,经过有效释放磷酸盐,累积了大量PHB 的除磷菌,进入好氧状态后,将消耗内部贮存的PHB和外源基质产生质子运动力,质子推动力可用来运输磷和产生ATP。从而使除磷菌在好氧环境中贪婪超量的吸收混合液中的磷。在氧化沟中,当污泥龄SRT>8d,溶解氧充足(DO>2.0mg/l)条件下,将生活着两类好氧型微生物即亚硝酸菌和硝酸菌,它们会利用CO3、HCO3 和CO2等无机碳作为碳源,第一步在亚硝酸菌作用下,将氨氮转为亚硝盐;第二步在硝酸菌作用,将亚硝酸盐转化为硝酸盐。同时有机物BOD5 将作为营养物质被活性污泥中的微生物摄取、代谢和利用、从而使污水得以净化。

1.4.4 固液分离区

泥水混合液流入侧沟沉淀区后,在固液分离器作用下,流速迅速降低,泥水混合液在上升过程中,絮状污泥撞到固液分离器,经过几次反复折射后其上升速度逐渐下降直至为零。此时,绝大部分絮状污泥在自身重力作用下开始沉降,在此深度出现了泥水界面,实现泥水分离。清水从上部出水堰流出,沉降到固液分离器下面的大部分活性污泥,被保持一定流速的混合液重新带入氧化沟,继续参与有机物的降解。另一部分增加的活性污泥,将作为剩余污泥经沉淀区底部排泥管,排至脱水机房,进行脱水处理,同时达到除磷的目的。

1.5 调试与运行

从工人师傅的口述以及我查看工作运行日记来看,2007年8月竣工至2008年9月期间,该污水处理厂进行了长达一年的调试工作,在摸索中寻找经验。调试前的准备工作:

(1)对格栅、泵房、曝气沉砂池、厌氧区、缺氧区、好氧区等所有构筑物及相连管道中的石块、木块、金属物等杂物进行彻底的清理工作。确保运

2--

行中的污水泵、污泥泵、脱水机等设备免受其损坏, 而造成不必要的经济损失,影响调试进程。

(2)对所有机电机械设备,构筑物及用电状况进行彻底的安全隐患检查,确保调试工作中人身与设备财产安全。

(3)组织设备厂家、安装公司、监理公司及单位相关人员对所有机电机械设备进行点动试车及联动试车。

活性污泥的快速培养与调试

当时正值汛期(8月),当地气温高雨水多,进水管道为雨污混流因此进入的生活污水被大大的稀释COD、BOD5 负荷偏低,如仅使用生活污水进行活性污泥的培养,营养物质的缺乏将是阻碍活性污泥快速培养成功的主要因素。为补充碳源,该厂特地向附近的习水酒厂运来一些酒厂废水,如仅使用酒厂废水,而COD、BOD5负荷太高,污水中有害成分又对微生物的增殖有一定的抑制和毒害作用。因此,为了实现活性污泥的快速经济培养成功,保证培养质量,决定在活性污泥的培养上,采用选择性进水、接种、培养、驯化同步进行,先间歇闷曝培养,后连续动态培养的方式。取一期氧化沟足够量活性污泥为菌种,于8月中旬开始活性污泥的培养,期间气温在22~29℃。初次,生活污水量与酒厂废水量按9:1的比例注满一体式氧化沟,闷曝24h后排出20%上清液,再补充等量的生活污水与酒厂废水的混合液。随着培养进程的推移,逐渐增大换水量,缩短闷曝时间,提高进水中工业废水的比例。

自此第3天氧化沟活性污泥浓度MLSS=1500mg/L、SV30=15.2%,污泥絮体形状良好,镜检:盾纤虫为优势种群,钟虫已现,但数量较少。此时,开始采用连续动态培养,每天监测COD、PH 值、SS、NH3-N等各项指标及镜检观察。在处理效果良好的情况下,逐步增加进水量,同时提高酒厂废水所占比例,使微生物逐步适应新的环境条件。至第9天时进水量已达到0.65万T/d。氧化沟中MLSS=2500mg/l SV30=16%。SVI=106。镜检:发现新生菌胶团大而密

实,钟虫、累枝虫大量出现,且为优势种群,轮虫数量适中,出水清澈稳定,COD、BOD5、NH3-N、SS 等各项指标已达到设计标准,说明活性污泥已经培养成熟。

当地环保部门提供的验收监测结果见表2。

1.6 运行故障问题与解决

从工作记录中得知,运行到9月2日发现出水悬浮物明显增多,三天后,情况进一步恶化,侧沟沉淀区泥水已经不能分离,活性污泥随出水大量流失。此时,氧化沟内活性污泥浓度MLSS=4500mg/l、SV30=46%、SVI=170、测定SV30时发现活性污泥分层沉降明显,且上层污泥很难沉降,取上层污泥镜检,发现大量真菌(FUNGI)且菌胶团小而松散。

1、原因分析

根据活性污泥各项质量指标及镜检情况, 造成大量活性污泥流失的主要原因是:氧化沟中出

现部分活性污泥膨胀、沉淀区底部流速过快、污泥浓度偏高、固液分离效果不佳。

从运行记录可以看出,这段时期氧化沟中推流器开启台数太多,使沉淀区底部混合液流速过快,而且此时活性污泥浓度(4500mg/l)较设计值

(3500mg/l)明显偏高,致使沉淀区泥位上升,是造成活性污泥流失的又一因素。

2、应对措施

(1)控制污性膨胀的进一步恶化,恢复污泥活性。停止酒厂废水进入,加大进水中生活污水

所占比例,采用活性污泥培养时期的方式,使污泥活性得以恢复。

(2)对不易沉降部分的活性污泥(即已膨胀的活性污泥)从沉淀区出水堰排出。

(3)增大曝气沉砂池的曝气量,使进水中如H2S等易使污泥膨胀的有毒气体,尽可能在曝气

池去除。

(4)将氧化沟活性污泥浓度MLSS控制在1400mg/l左右。

(5)合理开启氧化沟中设备台数,将氧化沟溶解氧控制2mg/l左右,沉淀区底部流速控制在

0.27m/s左右。采取了以上措施,七天后此现象得到控制,污泥活性得到恢复,第十天出水水质: SS=18mg/l、COD =45mg/l、BOD=18.8mg/l、

NH3-N=4.7mg/l。

1.7 结论

(1)实习期间监测结果表明,一体化氧化沟工艺,处理城市污水效果良好,稳定可靠,出水水质某些指标优于《城镇污水处理厂污染物排放标准》(GB18918-2002)一级标准中的B标准。COD去除率90.4%、BOD去除率93.2%、NH3-N去除率86.5%、SS去除率91.3%。

(2)设有厌氧、缺氧和好氧区,利用不同的微生物特性提高了废水可生化性,同时具备了脱氮除磷的功效。该厂每年对污染物削减量为:BOD5 876吨、COD 1205吨、SS 1260吨、NH3-N 82吨、TP17吨,对习水县实现污染物

减排的目标有着重要贡献。

(3)一体化氧化沟与其他污水生物处理技术相比,工艺流程短,减少了构筑物和设备,节约投资费用,降低机械事故率,有利于污水处理设施的维护和管理。

(4)特殊的水力学设计实现了污泥自动回流,不设二次污泥回流泵站,节约运行动力费。由于二沉淀与氧化沟合建,侧沟沉淀区底部流速,影响着活性污泥的沉降效果,决定着泥位的高低,也就直接影响出水中悬浮物的多少。而固液分离器,就是起着降低水流速度,实现固液分离的作用。因此,一体化氧化沟对固液分离器的技术性能有着更严格要求。

(5)通过与工人师傅的交流和翻阅运行记录本,总结出了污泥培养与系统启动运行的一些经验,为自己将来的污水厂管理工作积累了宝贵的财富。

1.8 存在的问题与今后发展趋势

问题:

(1) 污水处理厂建设资金短缺,运行经费有时候不能到位;

(2) 进口设备虽好,可是一旦损坏,其维修是个问题。建议加大设备

备件的开发力度;

(3) 污水处理工艺的选择有一阵风的现象,常不结合本地区实际情况

而是盲目选择热门工艺;

(4) 再生水买没有得到充分利用;

(5) 普遍缺少专门的高级人才。尤其是小型污水厂内缺少环境工程类

专业的技术人员;

今后的发展趋势:

(1) 经济发展与污水处理事业协调发展;

(2) 政府加大对环保产业的支持力度,多方筹资加速污水处理厂的建

设,以最短的时间控制、治理已造成污染的水环境;

(3) 改变污水处理行业的运营机制,由事业型向企业经营型转变;

(4) 环保要从娃娃抓起,提高全民的水环境忧患意识。

2.建筑给水排水工程——习水县人民医院门诊综合大楼

2.1 习水县人民医院简介

习水县人民医院是集医疗、教学、科研、康复、预防保健、业务指导为一体的县级综合性医院,承担全县近70万人民的防病治病任务。属“国家二级乙等医院”,并被评为“爱婴医院”、“贵州省高等医药院校教学实习医院”、“贵州省模范职工之家”、“贵州省院务公开先进单位”、“贵州省三八红旗先进集体”、“遵义市市级文明单位”、“遵义市医疗质量管理先进单位”。现有高级职称20人,中级职称70人,一线医务人员230人,共有员工260。分为门内科、普外科、病理科、神经外科、儿科、五官科、中医科、放射科、骨科、皮肤科、急诊科、生殖泌尿科、妇产科、血库、医教科等31个科室单位。能进行血液透析、多普勒超声诊断、CT、脑电图、震荡碎石等检查。

2.2 习水县人民医院建筑物概况

辖门诊综合楼(5层砖混)一栋,综合办公大楼(12层梁柱框架结构)一栋,住院1部(5层砖混)住院2部(6层梁柱框架结构)各一栋,篮球场一个,锅炉房1个、食堂一个、老年活动中心1个、停车场1个(面积400m2)。

门诊综合楼位于大门右方,坐北朝南,占地1200m2,总高21.2m。一层层高4.2m,其余各层层高3.4m。门诊一楼:西药房、挂号室、缴费室、护士站、普内科、专家内科、验血验尿化验室,二楼设有中药房、中医科、五官科、脑电图室、医保收费站,三楼设有皮肤科、神经内科;四楼设有儿科、放射科,五楼设有生殖泌尿科、医教科、中心血库、CT、彩超等辅助诊疗室。日门诊量约600人。每层楼有一东一西两处公用厕所,其中男卫生间小便器4个,大便器4个,女卫生间大便器4个。

2.3 医院建筑给水排水的特点

随着现代医学科学的迅速发展,新技术、新医疗设备层出不穷,从而与之相

符的现代化医疗建筑———医院,也面临着新的设计理念和新技术的运用。无论从医院建筑物功能、其所处的环境,还是医院建筑设备及装备系统,要求均愈来愈高。因为它不仅是保障日常工作生活的需要,而且与救治病人、促进康复、避免致残、挽救生命紧密相关。作为给排水专业的设计不仅需要满足医院建筑中设备上不同功能的要求,而且必须安全可靠。

(1)各门急诊科室,尤其是传染科病房各诊室、治疗室、洗涤盆都设非手动水咀。可采用肘式、膝式或脚踏式开关。如使用脚踏式开关一定要使用防渗漏的产品,以免使用处地面经常潮湿,使病员、医务人员滑倒,发生事故。

(2)医院的设备及装备系统内容繁多,功能特殊,要求很高。除了要求保证持续供给充分符合质量标准的用水外,更需要根据不同的医疗仪器以及不同科室对水质、水压、水温的要求,分门别类设置水处理系统和对系统进行增减压。

(3)医院的许多科室,尤其是检验室、化验室、放射科等科室中的酸洗池、消毒池、洗片池等下水管道应采用耐腐的PVC-U排水塑料管。

(4)对各类污、废水必须严格按国家有关排放标准分门别类,用不同的处理工艺进行针对性地处置和处理。达到无害化后才能排入市政管道。

2.4 医院建筑给排水系统设计心得

医院的设备及装备系统内容繁多,功能特殊,要求很高。除了要求保证持续供给充分符合质量标准的用水外,更需要根据不同的医疗仪器以及不同科室对水质、水压、水温的要求,分门别类设置水处理系统和对系统进行增减压。

门急诊、医技楼往往由于医疗功能需要,给排水横、立管布置较为散乱,

较多的明露在室内,有时加之暖通专业的管道,使房间内明露的管道过多,既不雅观,又影响卫生。这就要求在工程设计过程中,应充分利用不同的结构形式进行合理布置,根据功能需要尽量使各种管道隐蔽布置,在不影响使用的前提下,注意美观得体。

传统的医院热水供应系统中,人们基本上采用容积式热交换器。主要是考虑所提供蒸汽量与热水供应最大值之间差值的调节量,减小了蒸汽锅炉设计量,减少了锅炉房占地面积,节约了一次性投资。然而现在人们对水质要求愈来愈高,尤其是生活热水中发现军团菌致病的实例,引起人们的高度重视。主要是因为在30℃~55℃水中最容易繁殖军团菌,为此世界卫生组织(WHO)推荐:“热水应在60℃以上储存,并至少在50℃以上循环。如某些使用者,需要将水龙头水温降至40℃或50℃左右,这时可以使用调温混合阀来实现。

三 集中实习篇

1.听专家的报告

1.1 给水工程设计的讲座

3月9号上午8点半,在城环学院4楼多媒体视频教室内,来自西南市政设计研究院重庆分院给排水主任设计师马刚高级工程师为我们奉献了一场精彩的“给水工程设计”讲座。

马高工是我院82级杰出校友,先后承担了重庆市、四川省等多地的重要给水工程设计项目,在净水厂设计、给水管网设计等方面很有特色,经验丰富。讲座一开始,马高工概括起来说“给排水专业的东西很杂,很乱,作为一个公用设备工程师,需要知道很多的东西,很多书本上都没有的东西,需要我们在工作中不断总结,才能轻车熟路上手。然后他就结合自身工作实例“重庆市南溪县3万吨净水厂与配套管网设计工程”向我们讲述。

马工讲述了该设计中最重要的是要先熟悉两个规范:《室外给水设计规范》GB50013-2006和《生活饮用水卫生标准》GB5747-2006,对于重庆地区,由于夏季有高浊度水,最高浊度可达1万多NTU,所以需要采取必要的加强工艺,西南地区最常用的饮用水处理工艺是两级絮凝沉淀或者两级沉淀,即预沉、絮凝沉淀、过滤、消毒、出水,必要时可以在预沉池也设置加药系统。两个沉淀池之间设置超越管,当在常浊度进水条件下,来水就超越预沉池直接进入二级絮凝沉淀池,节省药耗和能耗。由于环境的破坏,水源水为微污染水时,要采取必要的加强措施。为去除BOD5和NH3-N,可以采取预氧化(O3、KMnO4),也可以采用后续深度处理:活性炭滤池、膜反应器。

新标准中的饮用水水质指标由原标准的35项增至106项,增加了71项。其中,微生物指标由2项增至6项;饮用水消毒剂指标由1项增至4项;毒理指标中无机化合物由10项增至21项;毒理指标中有机化合物由5项增至53项;感官性状和一般理化指标由15项增至20项;放射性指标仍为2项。现在的饮用水处理程度还没有完全达到《生活饮用水卫生标准》GB5747-2006的106项指标的要求,就是传统工艺不能达标。因此现在净水厂的设计需要增加深度处理的环节,这就为我们科研与设计工作者提出了更高的要求。

对于给水管网设计,马工针对重庆山地地形的特征,提出分压分级供水,避免整个管网压力过高、爆管事件频发,在设计时候不追求100%的管网都满足平差要求,只要90~95%的满足就可以了,对与难以满足部分,采用额外供水、单独供水的方式解决。

规范要求二沉池出水低于10NTU,马供建议最好低于5 NTU。适当降低二沉池负荷,增大占地面积,提高出水水质标准,可以使后续滤池的工作周期更长,减少反冲洗水耗量。从长远看,是值得的。

1.2 建筑给水排水工程设计的讲座

今天上午8点4分,在A区研究生院606教室,来自重庆市设计院的教授级高级工程师汤浩校友为我们讲解关于“建筑给排水设计”的设计经验。

汤前辈是我系63年毕业的元老级、重量级、高级别的设计师,从事给排水设计40多年,可谓资历深厚,经验丰富。他的报告分为5个部分:给排水专业设计范围与内容、民用建筑给排水设计步骤、国内外高层建筑情况、高层建筑消防、自动喷水灭火系统。

本专业设计范围包含市政工程与建筑工程,对于市政工程,我们主要负责其中城镇给排水管网、道路排水、净水厂、污水处理厂及部分环保工程的设计,对于建筑工程,含工业与民用建筑。

在设计之前,需要搜集相关资料,弄清楚水源水质与水压情况,以此选择供水方案,同时要和电气、暖通、结构等专业协调,彼此提供建议和帮助。设计中常分为可研、初设、施工图设计三个阶段,我们需要熟悉相关规范的要求,如《建筑给水排水设计规范》GB 50015-2003、《自动喷水灭火系统设计规范》GB 50084-2001等。通过水压等确定方案、之后可以计算水量、确定管径、选设备、出图。初设经过上级主管部门批复后,才可以做施工图设计,出图需要经过建委委托的审图中心的专家审核,各设计院之间彼此提意见或建议。审核通过后就可以进入施工阶段。

之后,汤前辈又给我们介绍了几种生活给水系统的特点,对于减压阀给水系统,他建议在减压阀之前设置一过滤器,预防阀中活塞淤堵而失效。

1.3 排水工程设计的讲座

今天上午9时,来自重庆市市政设计研究院的副院长、我系82级杰出校友程吉建高级工程师为我们讲述“城市排水工程设计”。程工主要结合自己所做的机场排水系统设计为我们讲述,山地城市排水系统的特点之一是管道埋深较平原城市深,这样一方面违背规范的要求,二来检修很不便,还有

安全隐患(如检查井)。因此需要设置必要的消能措施(如跌水消能井),控制埋深,降低施工难度,也节省造价。

雨水排水系统设计中有一个很重要的参数就是暴雨重现期,对于不重要的小城镇和重要的大城市,暴雨重现期的大小不一。重现期数值越大、水量越大、设计管径越大,造价越高。由于地方差异,每个地方的暴雨强度和周期不一,因此需要对其分别对待,同时兼顾城市的重要程度、人口等因素。

1.4 给排水规划的讲座

今天上午8点半,来自重庆市规划设计研究院的高级工程师、我系90级校友孙黎和我们一起探讨了给水排水专业在城市规划领域中的应用。孙师姐一来就给大家一种很亲切的感觉,她准备充分、逻辑严密、层次清晰。她的讲座包含了8个方面:城市规划编制的层次、水资源承载力在城市规划中的应用、山地城市给水排水规划的特点、城乡统筹下的给水排水、与生态环境保护的结合、规划的近、远期结合的问题、给水排水规划的编制、其他。

城市规划是对一定时期内城市的经济和社会发展、土地利用、空间布局以及各项建设的综合部署、具体安排和实施管理,也是各级政府统筹安排城乡发展建设空间布局,保护生态和自然环境,合理利用自然资源,维护社会公正与公平的重要依据,具有重要公共政策的属性。城市规划分为总体规划、分区规划、详细规划。

水资源承载力是—定的区域内,在一定的生活水平和生态环境质量下,天然水资源的可供水量能够支持人口、环境与经济协调发展的能力或限度。水资源承载力是影响城市规模的一项重要指标。

山地城市给水规划要求:

(1)水源点的选取与取水成本的综合考虑;

(2)水厂选址与地面标高的关系,不宜过低;

(3)山地城市通常存在以不同地形标高而采用分级供水形式,应注意

对地形的分析,采用合理、经济的分级数,以及合理布局加压泵站。

(4) 可在不影响城市建设用地的前提下,充分利用地形布局高位调节

水池;

(5) 管网布局以环状与枝状相结合

山地城市排水规划要求:

(1)按自然地形划分流域分水线并进行分析;

(2)按流域划分与相对集中原则相结合布局污水处理厂,并结合城市建设用地布局和人口密度分布情况,在合理性、经济性、技术性和可行性方面进行多方案比较;

(3)在经济性方面还应注意建设投资与运行成本的比较;

(4)雨水系统规划和防洪规划的结合问题;

(5)尽可能保留天然水系、自然冲沟,确属需要并在经过论证和水利等相关部门同意后才可进行人工渠化、改造,但同时应考虑排洪管道;

(6)对暴雨强度公式中的重现期,可在同一系统中采用同一重现期或不同重现期,干管和较重要地区采用3-5年,一般地区采用1-3年,特别重要地区可采用5-10年、20年或以上。

城乡统筹中给水规划特点

(1)从区域和水资源角度,为城乡发展提供强有力的水源保障支撑;

(2)大力强调城乡饮用水源保护;

(3)注重供水工程安全;

(4)加快乡村地区供水设施建设 ;

(5)加强区域协调发展;

(6)节水型社会建设 ;

城乡统筹中排水规划特点

(1)体现城乡统筹规划原则 ,注重环境保护、安全;

(2)加快中、小城镇生活污水处理建设;

(3)加强农村水污染防治及污水处理建设;

(4)注重工业废水处理的控制;

(5)城市排涝规划;

1.5 给排水消防工程的讲座

今天上午8点半,重庆市公安消防总队建审处的我校95级校友、邹俊少校工程师为我们讲述“建筑消防给水系统”。邹工身穿警服,器宇轩昂。从事建筑审查10年以来,累计审核工程1500个以上,在建筑消防方面有丰富的经验和深刻的感悟。

消防灭火系统根据使用灭火剂的种类和灭火方式可分为:消火栓给水系统、自动喷水灭火系统、

其他使用非水灭火剂的固定灭火系统:如CO2灭火系统、卤代烷替代物灭火系统。

以使用广泛的消火栓灭火系统为例,其组成包含:消火栓设备(水枪、水带和消火栓组成,均安装于消火栓箱内)。水泵接合器、消防管道、消防水池、消防水箱。其消防给水方式可分为:由室外给水管网直接供水的消防给水方式、设水箱的消火栓给水方式、设水泵、水箱的消火栓给水方式、设水池、水泵的消火栓给水方式、设水泵、水池、水箱的消火栓给水方式、分区供水方式。

他接着介绍了水枪充实水柱长度、消火栓布置、消防水池容积、消防水箱的最小消防贮水量等专业术语的意义。

消火栓灭火系统介绍结束后,邹工向我们介绍了自动喷水灭火系统,其由喷头、报警阀、水流报警装置、延迟器、火灾探测器等组成,在高级娱乐场所、人流密集的场所应用广泛。

最后,邹工谈了几点他多年审图中的经验,诸如室外消防管网应形成环

30

状,且应尽可能形成“真环”,确保管网的供水可靠性等的建议,对我们很有帮助。同时,他还勉励我们踏实工作,严谨设计,安全第一,质量重于泰山。

2.参观西南医院建筑给水排水系统

由于时间原因和指导教师的进度安排等情况,该项将在毕业设计期间以本小组为单位进行。拟定指导人为本专业90级校友,重庆大学建筑设计研究院的赵赢工程师,拟参观学习西南医院的建筑给水排水系统,此处不多做作深究。

四 实习收获与心得体会

很快,三周的实习时间就过去了。在这三周的实习时间我学到了很多课本上不可能学到的知识。现就实习情况做如下总结:

通过实习,我知道了学习的重点,增加了对本专业的整体性认识,提高了自己解决实际问题的能力;通过实习,提高了自己的识图能力,对施工图纸的认识,有了更大的跨越;通过实习,增强了理论联系实际的能力,弥补了课堂上的不足;通过实习,为毕设做了较好的巩固,也为自己毕业后走上社会工作奠定了一定的基础;通过实习,培养了我吃苦耐劳的精神,更学到了如何与现场施工人员、技术人员沟通的技巧。

我们这次实习内容相当丰富,增强了我的工程意识和创新意识,对自己专业的就业方向和就业前景有了比较全面的认识,能够对将来的择业提供很多有益的参考。不管是在污水处理厂,还是在学校听专家的报告,都极大的开阔了眼界,使自己对专业的认识有前所未有的提高。

参看文献:

[1]王洪臣, 等. 城市污水处理厂———运行控制维护管理北京: 科学出版社. 1997.11

[2]徐亚同、史家辉, 等. 污染控制微生物工程, 北京: 化学工业出版社、环境科学与工程出版中心出版发行. 2001.05

31

[3]胡家骏、周群英, 等. 环境工程微生物学, 高等教育出版社

[4](美) 格雷迪( Grady, jr,C.P.L) ,(美) 戴吉尔( Dargger, G.T.) ,(美) 林( Lrm, H.C) 著. 废水生物处理: 改编和扩充: 第二版/ 张锡辉, 刘勇弟译北京: 化学工业出版社会. 2002.12

[5]李军, 杨秀山, 彭永臻. 生物与水处理工程. 北京: 化学工业出版社会性. 2002.09

[6] GB50015-2003建筑给水排水设计规范[S]

[7] 鲁雪利.浅谈建筑给排水中噪音问题及防治. 甘肃科技[J],2006 年 11 期198-199

[8] 申永平.UPVC排水管在多层住宅中的应用问题探讨.科技资讯[J],2006年第5期:105

[9] GB50045-95高层民用建筑设计防火规范[S],2005

[10] 王增长.建筑给水排水工程[M].高等教育出版社

[11] 张智、蒋绍阶、张勤. 给排水科学与工程专业毕业设计指南[M]第二版.中国水利水电出版社2008

32


相关内容

  • 给水排水工程专业评估调研报告
  • 通过对建设部评估标准的学习,对我校给水排水专业现状的分析,我们深刻的认识到评估工作的严峻性和紧迫性——实验室条件落后;部分教学资料有待改善;教学文件、教学档案等亟待整理,迎评准备时间短,工作任务重。通过调查,截至2010年6月,已有19所高校通过建设部高等教育司给水排水专业评估,包括清华大学、同济大 ...

  • 给排水专业就业方向参考
  • 一.建筑设计院 而一般院校和重点院校的教学质量在他们观来是有一定差别的 给排水专业(含研究生)就业: 概况: 1.设计院 最好有甲级资质的(特指给排水专业甲级资质) 设计院又分好多种: 一.建筑设计院 比较好的院:北京建筑院.天津建筑院.上海现代.同济建筑院.以及东北建筑院还有若干规模较大的省级院主 ...

  • 给排水.环境工程.建环就业方向,大家参考
  • 而一般院校和重点院校的教学质量在他们观来是有一定差别的给排水专业(含研究生)就业: 概况: 1.设计院 最好有甲级资质的(特指给排水专业甲级资质) 设计院又分好多种: 一.建筑设计院 而一般院校和重点院校的教学质量在他们观来是有一定差别的给排水专业(含研究生)就业: 概况: 1.设计院 最好有甲级资 ...

  • 给水排水工程专业考研
  • 给水排水工程专业考研前你想知道点什么 1.专业介绍: 本专业主要培养从事给水工程.排水工程.建筑给水排水工程.水污染控制和水资源利用与保护的规划.设计.施工.运行管理.科研和教学等方面工作的高级工程技术人才. 学生通过系统学习,主要掌握给水排水工程.水污染控制和水资源利用与保护等方面的基本理论.基本 ...

  • 2011级给排水科学与工程专业培养计划2
  • 给排水科学与工程专业本科培养方案(送审稿) (Undergraduate Program for Specialty in Science and Engineering of Water & Wastewater) 一.修业年限及授予学位名称 Ⅰ.Length of Schooling a ...

  • 03 建筑设备工程技术
  • 建筑设备工程技术专业教学标准 一.专业名称 建筑设备工程技术 二.专业代码 560401 三.招生对象 高中毕业生 四.学制与学历 三年 专科 五.就业面向 建筑设备工程技术专业定位见表1 表1 建筑设备工程技术专业定位 六.培养目标与规格 (一)培养目标 本专业培养拥护党的路线,适应社会建设需要, ...

  • 给水排水工程专业
  • 给水排水工程专业 概述: 本专业学习城市给水工程.排水工程.建筑给水排水工程.工业给水排水工程.水污染控制规划和水资源保护等方面的知识.培养能在政府部门.规划部门.经济管理部门.环保部门.设计单位.工矿企业.科研单位.大.中专院校等从事规划.设计.施工.管理.教育和研究开发方面工作的给水排水工程学科 ...

  • 土木工程毕业调研报告
  • 分类号: 单位代码 : 调研报告 姓 名 学 号 年 级 专 业 2009级 土木工程 系 (院) 建筑学院 指导教师 2013 年 4 月 24 日 建筑学院调研报告 专 业: 姓 名: 土木工程 班 级: 学 号: 2009级02班 土木工程专业就业形势调查报告 摘要:介绍了当前国内国际的基建市 ...

  • 大学工学专业介绍:给排水科学与工程
  • 主干学科:土木工程.水利工程 主要课程:工程力学.测量学.水力学与水泵.水处理微生物学.普通化学. 专业概况 教学实践 测量实习.工程制图.计算机应用及上机实习.水力学实验.微生物实验.水质分析实 验.水处理实验.课程设计.认识实习.毕业实习.毕业设计(论文) 等,一般安排40周左右. 培养目标 专 ...