FTTx施工工艺标准

FTTx 施工工艺标准目录FTTx 施工工艺标准(讨论稿)............................................................................................... 1 一、 二、 ㈠ ㈡ 总则 ........................................................................................................................ 3 局端设备安装 ........................................................................................................ 3 局端设备布局规划 ................................................................................................ 3 局端端设备安装标准 ............................................................................................ 4四、ODN 建设 ...................................................................................................................... 6 ㈠ODN 层次结构 .............................................................................................................. 7 ㈡ODN 规划 ...................................................................................................................... 7 ㈢PON 口容量规划 ........................................................................................................... 9 五、光缆线路施工 ............................................................................................................... 9 ㈠ ㈡ ㈢ ㈣ 光缆线路敷设 ...................................................................................................... 10 光缆线路防护 ...................................................................................................... 16 引上及引入 .......................................................................................................... 18 接地 ...................................................................................................................... 20㈤接续与成端 ................................................................................................................. 20 六、分线设备安装 ............................................................................................................. 21 ㈠ODF 设备安装 ............................................................................................................. 21 ㈢ ㈣ 交接箱安装 .......................................................................................................... 23 分线盒安装 .......................................................................................................... 25七、ONU 设备安装 ............................................................................................................ 26 ㈠ 综合配线箱安装 .................................................................................................. 26㈡ONU 安装 .................................................................................................................... 26 ㈢电源引入 ..................................................................................................................... 27 ㈡ 接地防护 .............................................................................................................. 27八、测试 ............................................................................................................................. 27㈠光缆测试 ..................................................................................................................... 27 ㈡OLT 测试 ...................................................................................................................... 28 ㈢ODN 测试 .................................................................................................................... 28 ㈢ONU 测试 .................................................................................................................... 30 九、附则 ............................................................................................................................. 30一、总则1、 参 照 《 公 用 计 算 机 互 联 网 工 程 设 计 规 范 》 ( YD 5037-2005 ) 、 《公用计算机互联网工程验收规范》 ( YD 5070-2005) 、 《中国移动 PON 网络工程施工及验收规范》 (QB-G-001-2011)制定本工艺标准、 《铁通公司宽带优质 网络实施指导意见(试行) 》 。 2、 本标准为建设的工艺标准,不包括经济指标。 3、 建设的网络应具有可运行性、可管理性、可增值性 和可扩充性。 4、 本标准适用以 FTTx 方式的宽带接入网的建设。 5、 施工前对施工使用的器材要进行检验,技术指标满 足《大楼通信综合布线规范》 (YD926.1~3-2009 )系列标 准要求,不合格的器材严禁使用。 6、 在施工过程中执行本标准特别困难时,应充分论述 理由,并报请建设单位批准。 二、 局端设备安装机房要符合《公用计算机互联网工程验收规范》 (YD/ T 5070- 2005)有关标准。 ㈠ 局端设备布局规划 根据工程经验,建议大中城市客户密集区域半径可按照2~5 公里规划,城市其他有业务需求的区域可按照 5~10 公里规划,城市郊区或乡镇可按 10 公里左右规划,但 OLT 的具体覆盖范围需要根据实际情况确定。 以单局点用户 (指 ONU 的以太网端口数或 ONT 的个数) 规模不低于 2000 户为原则来设置 OLT 的数量。 ㈡ 局端端设备安装标准 1. 机架设备 ⑴机房内机架设备的平面位置、机面朝向、机架相互距 离应符合工程设计要求。 ⑵机架设备安装应端正牢固。机架设备安装必须按设计 所要求的抗震加固措施进行加固,并符合有关的通信设备安 装抗震设计规范。 ⑶机架安装后各直列上、下两端垂直倾斜误差应不大于 3mm。 ⑷除有特定的绝缘隔离、散热、电磁干扰等要求外,机 架应紧密相互靠拢。 ⑸列间距离与设计的误差应不大于 5mm 。主走道侧必 须对齐成直线。列内机面平齐,无参差现象,机面对齐误差 不大于 5 mm。 ⑹机架及机架内设备的所有紧固件必须拧紧,同类螺丝 露出螺帽的长度应一致。⑺机架上的各种零件不得脱落或碰坏,漆面如有脱落应 予补漆。各种文字和符号标志应正确、清晰、齐全。 ⑻机架必须按施工图的抗震要求进行加固。 ⑼告警显示单位安装位置端正合理,告警标示清楚。 2、子架安装 ⑴面板布置应符合设计规定。 ⑵子架与机架的加固应符合设备装配要求。 ⑶子架安装应牢固、排列整齐,插接件接触良好。 ⑷子架安装完毕应按建设方要求做好标识。标识应统 一、清楚、明确,位置适当。 3 、电缆走道、桥架安装要求 ⑴电缆走道、桥架的安装位置、高度应符合工程设计要 求,偏差不得超过 50mm。 ⑵电缆走道、桥架扁钢平直,无明显扭曲和歪斜。 ⑶安装好的电缆走道、桥架应平直,各横铁规格一致, 两端紧贴走道扁钢和 横铁卡子,横铁与走道扁钢相互垂直, 横铁卡子螺钉紧固。 ⑷横铁安装位置应满足电缆下线和做弯要求,横铁排列 均匀。当横铁影响光 缆曲度半径时,可做适当调整。 ⑸电缆走道的地面支柱安装应垂直稳固,允许垂直偏差 为 1.5‰; 同一方向 的立柱应在同一条直线上, 当立柱妨碍 设备安装时,可适当移动位置。⑹沿墙水平电缆走道应与地面平行,沿墙垂直电缆走道 应与地面垂直。 ⑺ 电缆走道穿过楼板孔或墙洞的地方,应加装子口保 护。电缆放绑完毕后, 应有阻燃材料封堵。 ⑻ 列间撑铁的安装应在一条直线上,两端对墙加固应 符合设计要求。 ⑼ 吊挂安装应牢固、整齐,保持垂直,吊挂构件与电 缆走道漆色一致。 ⑽铁件的漆面应完整无损,如需补漆,其颜色与原漆色 应基本一致。 ⑾ 安装沿墙单边或双边电缆走道时,在墙上埋设的支 持物应牢固可靠,沿水平方向的间隔距离均匀。安装后的走 道应整齐一致,不得有起伏不平或歪斜现象。 ⑿安装走道应符合下列规定: ①水平走道应与列架保持平行或直角相交,水平度每米 偏差不超过 2mm。 ②垂直走道应与地面保持垂直并无倾斜现象,垂直度偏 差不超过 3mm。 ③走道吊架的安装应整齐牢固, 保持垂直, 无歪斜现象。四、ODN 建设㈠ODN 层次结构 ODN 主要分为主干层、配线层和引入层三个层次。 主干层:系指机房至主干光缆交接箱之间的光网络,包 括机房 ODF 架至主干光缆交接箱的光缆及配线设备。 配线层:系指主干光缆交接箱至用户住地网交接箱第一 级分光器之间的光网络。包括主干光缆交接箱至用户住地网 交接箱间的光缆及配线设备。 引入层:系指用户住地网交接箱第一级分光器至引入用 户所在楼内最靠近用户侧光缆分线箱 (FTTB 方式时的 ONU 机箱)之间的光网络。包括分光器至末端分线设备之间的光 缆及分光、配线设备。 引入用户室内的光缆为综合布线。 ㈡ODN 规划 在 PON 网络的部署中,分光器放置根据用户以及局方 机房的分布有不同的方式。不管采用何种方式,放置分光器 尽量做到以下几条原则: 1、便于日后的维护管理 2、提高分光器端口的使用率 3、节约投资,减少光缆使用量 4、便于网络的升级 以下是 PON 网络中几种典型的分光器放置:1、分光器集中分光集中放置(1 级分光)⑴分光器集中放置在中心机房(靠近 OLT) 采用该组网结构一般来说中心机房与用户侧的距离比 较近,这里中心机房也可以是小区机房,小区住宅用户密度 一般也较高。 ⑵分光器集中放置在用户侧(靠近 ONU) 中心机房与用户侧的距离比较远,但用户密度较高。用 户侧一般为可以放置多个分光器的室外光分配箱或交接箱, 也可以是大楼内的 ODF 架 2、分光分散放置(1 级分光) 这种 PON 网络结构中机房与用户的距离比较远,用户 数不是非常密集。用户侧为可以容纳 1 个分光器室内型的光 分配箱。 该 PON 的网络结构实际上和分光器集中放置在用户侧 本质上是一样的。 3、分光器分散放置(2 级分光) 2 级分光可以有多种组合,典型的组合 EPON:1:4×1:8, 1:2×1:16 GPON :1:4×1:8,1:8×1:8 , 1:4×1:16 第 1 级分光器可以集中放置在中心机房或者光交接箱 里,也可以分散放置在接头盒里。第 2 级分光器放置在靠近用户侧分线盒内。 ㈢PON 口容量规划 在光功率预算满足的情况下, PON 口所能接入的用户数 要综合考虑用户业务带宽需求和光分路器的分光能力。 用户带宽规划法:单个 PON 口下接入用户数=PON 口 下行带宽×带宽冗余系数/(用户承诺带宽×用户并发率×流量 占空比) 。 分光比规划法:单个 PON 口下接用户数=总分光比× ONU 以太网口数(或 ONT 个数) 。 PON 口下行容量取两种方法计算值较低的作为规划参 考。 五、光缆线路施工 敷设工艺必须符合 YD5102-2010 《通信线路工程设计规 范》和 YD/T5121-2010《通信线路工程验收规范》的要求。 余留长度及弯曲半径标准见下表: 光缆预留长度要求及增长参考值项目 接头处每侧预留长度 地下局站每侧预留长度 地面局站内每侧预留长度 敷设方针 直埋 管道 架空 5~10m 5 ~ 5~10m 10m 5~lOm。 可拨实际需要适当调 整 1O~20 m。 可按实际需要适当调整 因水利、道路、桥梁等建设规划导致 按实际需要确定 的预 因接入中间人孔预留 根据需要光缆最小弯曲半径标准光缆外护层形式 静态弯曲 动态弯曲 无外护层 04 型 53 、 54 、 33 、 34 333 型、 43 型 型 10D 12.5D 15D 20D 25D 30DD-光缆外径 光缆线路与其它建筑物的要求应符合 YD/T5121-2010 《通信线路工程验收规范》附录 C “光缆线路与其他建筑设 施的间距”的要求。 ㈠ 光缆线路敷设 1、 架空敷设 ⑴架空光缆敷设后应自然平直, 并保持不受拉力、 应力, 无扭转,无机械损伤。 ⑵架空光缆垂度为吊线原始垂度、光缆结构重量及架挂 方式多方面因素形成。应符合 YD/T5121-2010《通信线路工 程验收规范》的要求。 ⑶光缆挂钩的间距应为 500 mm,允许偏差士 30 mm。 挂钩在吊线上的搭扣方向应一致,挂钩托板应安装齐全、整 齐。 在电杆两侧的第一只挂钩应各距电杆 250 mm ,允许 偏差士 20mm。见下图光缆的挂钩程式应根据设计要求选用,详见下表:光缆 直径 光缆 挂钩 程式 (mm) 32 以上 65 32 以下 55 24 以下 45 18 以下 35 12 以下 25⑸布放吊挂式架空光缆应在每 1~3 根杆上作一处伸缩 预留。伸缩预留在电杆两侧的扎带间下垂 200mm 伸缩预留 安装方式应符合下图的要求。光缆经十字吊线或丁字吊线处亦应安装保护管。符合下 图要求:⑹ 架空光缆在吊线接头处的吊扎方式应符下图的要 求。⑺架空光缆接头盒应固定在距电杆 1.5 米处,接头盒应 使用紧固件与钢绞线之间固定牢固。为防盗可使用扎线捆扎 3~5 圈。 ⑻一般情况下,光缆跨越公路要套反光管, 吊线跨路与路 面距离大于 5.5m。 ⑼在电杆的一侧及十(丁)字交叉处应安装光缆标识挂 牌。2、 管道敷设 敷设管道光缆的孔位应符合设计要求。 ⑴在孔径 90mm 及以上水泥管道、钢管或塑料管道内, 应根据设计规定在两人(手)孔间一次性敷设三根或三根以 上的子管。 ⑵子管不得跨人(手)孔敷设,子管在管道内不得有接 头。 ⑶子管在人(手)孔内伸出长度一般为 200~400mm; 本期工程不用的管孔及子管管孔应及时按照设计要求进行 封堵。光缆敷设前应按“8”字盘放,管井边缘要做好保护,防 止光缆外皮被刮破。敷设应符合下列要求: ⑷应按设计要求的 A、B 端敷设光缆。 ⑸敷设光缆时的牵引力应符合设计要求。 ⑹光缆在各类管材中穿放时,管材的内径应不小于光缆 外径的 1.5 倍。⑺光缆出管孔 150mm 以内不得做弯曲处理。 ⑻管道光缆根据接入需要按设计要求进行中间人孔预 留。光缆余长应在人孔内盘放并固定。 ⑼敷设后的管道光缆在人(手)孔内应排列、固定整齐。 光缆在人(手)孔内子管外的部分应按设计要求保护。 ⑶管孔及子管管孔均应按设计要求的材料进行堵塞。 ⑾光缆在每个人孔内按要求做好标识。如下图:3、直埋敷设 直埋光(电)缆埋深应满足通信光缆线路工程设计要求的 有关规定,具体埋设深度及与其他建筑设施平行或交越时的 最小净距应符合YD/T5121-2010《通信线路工程验收规范》 的要求。 4、沿墙敷设 ⑴吊线式墙壁光缆使用的架设材料规格应符合附录 H 的要求。 ⑵钉固式墙壁电缆选用的卡钩应与光缆外径(或光缆保护管外径)相匹配,当采用金属卡钩时,光缆在卡钩处应采 用塑料管防护。 ⑶末端和转弯处两侧采用双卡购固定。 ⑷末端、分歧、转弯及引入处应挂设光缆标识。 ⑸敷设标准应符合 YD/T5121-2010 《通信线路工程验收 规范》6.4 的要求。 5、槽(过)道内敷设 ⑴槽(过)道内敷设光缆时,要将光缆绑扎在内部支架 上,光缆要平直,弯曲半径符合规范要求。 ⑵在桥梁等震动较大的槽道内敷设光缆时应采取防震 措施。 ⑶同一槽道内敷设多条光缆时,各条光缆应顺向排列, 不应有交叉。 ⑷槽(过)道内敷设的光缆不应采用铠装或油麻外被层 光缆。 ⑸引出槽道时,与槽壁的交叉处应采取防护措施。 6、蝶形光缆敷设 ⑴蝶形光缆程式应与采用的敷设形式相适应。 ⑵在槽道内敷设时参照在槽道内敷设光缆时的标准。 ⑶在引户内且采用明布时,宜使用卡钉钉固,卡钉距离 宜为 400mm。 ⑷引入用户户内采用线槽敷设时,线槽应横平竖直。⑸引入用户户内的敷设位置及敷设方式应事先值得用 户同意。 ㈡ 光缆线路防护 1、 直埋光缆在跨越城市主干道及主要公路时,应采用 钢管防护,保护管起止点在路基两侧排水沟外应≥1 m. 保护 管埋深应大于排水沟永久沟底以下 500 mm。在跨越城市次 干道以下及乡村公路时可采用硬质塑料管防护,其长度和埋 设深度与钢管同。 2、 受地形影响埋深达不到要求时,应采取防护措施。 防护可采用水泥槽、复合材料防护槽、硬质塑料管或钢管。 3、 架空光缆跨越道路时除距离路面净间距应满足要求 外,还应加挂标志牌。 4、 沿墙敷设的转弯处,墙角处于转弯的弯内时,转弯 处应采用塑料管防护。 5、 架空及沿墙敷设时的余留光缆应盘成圆圈,并固定 在十字盘留架中,然后固定在吊线或墙壁上。圆圈的半径不 得小于规范规定的弯曲半径。 6、 光缆穿越墙壁时,墙洞内应采用塑料管防护。墙洞 两侧应留有滴水弯。 7、 采用管、槽防护时,管、槽应横平竖直。管、槽应 尽量贴近楼顶, 一般情况下距离天花板距离不应大于 50mm,沿楼梯斜坡敷设管、槽时,管、槽应与楼梯的斜坡平行。管、 槽接头处应采用相应型号的接头材料对接。槽底每间隔 0.5~1m 钉固一个钢钉,每根槽底两端在距端头 100mm 处 必须钉固一个钢钉。两根塑料槽直通连接时,可错开槽底与 槽盖的接头位置直接连接,而不采用专用接头。塑料管防护 时,所选用的卡钩应与管径相适应,每间隔 400 ~500mm 钉固一个卡钩。 8、 管道内的余留光缆盘成圆圈固定在人孔壁上的支架 上,不得平放在人孔底部。 9、 光缆接头处两侧金属构件不作电气连通。 10、 局站内的光缆金属构件应接防雷地线。 11、 光缆在桥上敷设时,应考虑机械损伤、震动和环 境温度的影响,并采取钢管或塑料管等相应的保护措施。 12、 吊挂式架空吊线与电力线交越时,一般应从电力 线的下方通过,与电力线交越部分的架空吊线应外套电力线 保护管。吊线与电力线间距应符合 YD/T5121-2010《通信线 路工程验收规范》附录 C 的要求。安装的电力线保护管的 材质、规格、长度应满足设计要求。 13、 光缆在不可避免跨越邻近有火险隐患的建筑设施 时,应采取防火保护措施。㈢ 引上及引入 引上钢管上端 口距离地面间距不 应小于 2.5m, 引上 管的上、下端应固 定在电杆或墙壁 上。引上管上端口 应密封。 1、 沿 电 杆 引 上。 ⑴ 露出引上管的垂直部分光缆应采用塑料管防护。⑵ 引上光缆在露出引上管 150mm 处开始进行绑扎,向上每 间隔 500mm 进行一次绑扎, 最上端距水平吊挂光缆 150mm 处做一次绑扎。如上图所示。 2、 沿 墙 引上。 ⑴ 在 距 引上管上端口 和地面处对引 上管进行固定。 ⑵ 引 上 后沿墙引入机 房时, 在引人口 处应留滴水弯。 ⑶ 露 出 引上管部分应 采用塑料管防 护。 3、 引入 ⑴ 光缆在地上引入室内时,光缆在墙洞内引采用塑料 管防护。 ⑵ 在墙外侧应留滴水弯,防止雨水沿光缆流入室内。⑶ 引入光缆后应将墙洞全部密封。交接箱引入光缆后 其所有引入孔应密封。 ⑷ 光缆引入箱盒时, 箱盒的引入口边沿应塑胶圈防护, 防止箱盒金属壁伤害光缆 ⑸ 光缆引入交接箱后,其加强芯应牢固固定到交接箱 的固定件上,其外护套的开拔边沿应用塑料胶带包扎。 ⑹ 交接箱门与箱体之间应采取密封措施。 ⑺ 所有箱盒都要加锁。 ⑻ 所有光缆引入点都应挂标志牌。 ㈣ 接地 一般地段,采用电悬浮方式进行防涝及防强电,即光缆 在接续时金属加强芯两端既不连接也不接地,但在接续操作 过程中采取临时接地措施,接续完成后拆除。在强电干扰严 重地段采用全介质光缆。 ㈤接续与成端 1、 光缆接续与成端 ⑴ 光缆接续前应核对缆的端别、纤序,接续后不得 出现纤序错接。光缆端别及纤序应作识别标志。 ⑵ 直埋光缆的接头应选择在地势平坦和地质 稳定的地点,应避开水塘、河流、沟渠及道路等;管道光缆和架空光缆的接头应避开交通要道口 ; 架空光缆 的接头应落在杆上或杆旁 1~1.5m 左右的位置。 ⑶热可缩套管热缩后应外形美观,无变形,无槽皱,无 烧焦,无喇叭口,熔合处无空隙、无脱胶、无杂质等不良状 况。 ⑷ 光缆接头盒密封后应保持良好的水密性和气密性。 ⑸ 热可缩管应套入编号后全部顺序卡入托盘的卡槽内。 ⑹ 光纤应留在托盘内,不能与热可缩太高叠压。 ⑺应把填有接续日期、天气、温度、每纤的接续推断损 耗、接续人员姓名等资料的接续卡片放置在接头盒内。 2、蝶形光缆成端 蝶形光缆敷设时采用整段光缆敷设,中间不应有接头。 成端时采用适配器在蝶形光缆上直接成端,禁止在蝶形 光缆上接续尾纤的方式成端。 六、分线设备安装 ㈠ODF 设备安装 1、机架安装 参照局端设备机架安装部分。 2、子架安装 参照局端设备子架安装部分。 3、其它要求⑴安装在光纤(总)配线架内同一层的一体化单元框应 在同一平面上,同一列一体化单元框应在同一垂直线上。同 一框内的一体化托盘应无凹凸现象。 ⑵光纤终端单元的安装应符合下列要求: ①同一层光纤终端单元应在同一平面上,同一列光纤终 端单元应在同一垂直线上。 ②光纤终端单元转动灵活。 ③光纤终端单元转动时不应抻拉设备光缆和跳纤。 ⑶光纤(总)配线架走纤槽道的安装应符合以下要求: ①各架之间的走线槽道应连接固定。 ②固定走线槽道的螺栓不得对光跳纤造成损伤。 ⑷跳纤的敷设应符合以下要求: ①光纤的选型及结构应符合设计要求。 ②跳纤选用的连接器插头类型应与线路侧一体化单元 框和设备侧终端单元上的适配器匹配。 ③跳纤的布放应整齐,并应根据光纤总配线架的类型走 一定的路由,不得混乱。架内跳纤与架间跳纤应分别走线, 先布放架内跳纤,后布放架间跳纤。 ③储纤长度不宜超过 1m,以最大限度地减少架内冗余 光纤。 ⑤根据光路性质选择跳纤的颜色,并满足各运营商的要 求。㈢ 交接箱安装 交接箱的安装方式、地点与型号应符合设计要求。箱体 无变形、掉漆等现象。 1 落地安装 ⑴采用落地方式安装时,交接箱应安装在预先制作好的 底座上。 ⑵ 安 装 底 座 边 沿 应 比 交 接 箱 底 部 边 沿 大 出 50 ~ 200mm。 ⑶安装底座边沿应比交接箱边沿底 10~20mm 并做成 漫坡,防止底座顶部积水。 ⑷交接箱应牢固的固定在底座上。 ⑸用砖砌底座时,底座表面应抹一层水泥沙浆。 安装完成后如下图所示2 壁挂安装 交接箱四角用膨胀螺栓固定在墙壁上,立沿应与地面垂 直, 偏差不应大于 1°。 交接箱下沿距地面不应小于 1500mm。 3 光缆引入 光缆引入后交接箱的引入口和引入管的端口都应封堵。 沿墙敷设光缆引入壁挂式交接箱时,在引入口处应留滴水 弯,多条光缆同时引入时光缆应排列整齐,引入口处应采用塑胶圈防护。 室外壁挂安装时光缆不得在上部引入。 4 接地防护 箱体的接地应满足设计要求。 5 标识 ⑴ 箱体标识 箱体正面左上部喷涂(粘贴)企业标识,在箱体右下部 喷涂(粘贴)编号。编号一般由 3 部分组成:第 1 部分标识 区域(由 2 个汉字组成) ,第 2 部分标识箱盒的类别(由 1 个字母组成) ,第 3 部分为顺号(由 3 位数字组成) 。 ⑵ 光缆标识 ①光缆标识 在光缆上挂标志牌,标识光缆的型号,去向,长度。 ②配线标识 跳纤应粘贴标签,标明跳纤用途。 ㈣ 分线盒安装 1、 安装 盒体应牢固固定在墙壁上,立沿应与地面垂直,偏差不 应大于 1°。 2、标识 ⑴盒体标识盒体正面上部标识喷涂 (粘贴) 企业标识, 下部喷涂 (粘 贴)编号。盒体距地面不应小于 1500mm。 ⑶ 配线标识 引入户内的配线粘贴标签,标识去向。 七、ONU 设备安装 ㈠ 综合配线箱安装 1、 安装 ⑴室外安装时应采用带防雨沿的箱体或采取防雨措施 ⑵盒体应牢固固定在墙壁上,立沿应与地面垂直,偏差 不应大于 1°。箱体下沿距地面应≥1500mm。 ⑶体内配线应理顺并绑扎。 ⑷室外安装时光缆不得在上部引入 2、 标识 体正面左上部喷涂(粘贴)企业标识,在箱体右下部喷 涂(粘贴)编号。编号一般由 3 部分组成:第 1 部分标识区 域(由 2 个汉字组成) ,第 2 部分标识箱盒的类别(由 1 个 字母组成) ,第 3 部分为顺号(由 3 位数字组成) 。 ㈡ONU 安装 ONU 应牢固固定在综合配线箱的固定架上。 其 RJ45 接 口朝向应便于插拔网线。㈢电源引入 电源引入机箱时及在箱体内应与电缆分开, 敷设的电源 线应采用塑料管防护。 ㈡ 接地防护 ⑴ 接地防护应符合设计要求。 ⑵在有等电位体的楼内安装时其接地线可连接至大楼 的等电位接地体。 ⑶各接地线都应直接连接至汇流排上 八、测试 ㈠光缆测试 1、 单盘测试 光缆运至施工地点后应进行单盘测试, 波长范围: 上行:1260~1360nm 下行:1480~1500nm (CATV:1550nm) 2、竣工测试 ⑴接续损耗测试 采用 OTDR 冲出每个接续点的接续损耗并做好记录。 ⑶ 户光缆测试用光源光功率计测出每条用户光缆的总损耗并做好记 录。 ㈡OLT 测试 测试内容:OLT 发光功率 1、OLT 参数指标:(单位:dBm) GEPON GPON ClassB+ 平均发射功率 最大接受灵敏度 波长范围: 上行:1260~1360nm 下行:1480~1500nm (CATV:1550nm) 2、测试仪表 光功率计 3、测试方法 OLT 设备加电稳定工作后,用光功率计逐端口测试。 ㈢ODN 测试 测试内容:ODN 全程损耗 1、网络参数 ODN 网络 (物理媒体独立层)的参数 1.5~5 -28 GPON-PX 20 +2~+7 -27 EPON-PX 10 -3~+2 -24设备类 型 EPON最大允许衰减 光器件类型 1000BASE-PX20 1000BASE-PX20+ CLASS B CLASS B+ CLASS C CLASS C+ 上行: 1310nm 下行:1490nm 24dB 28dB 25dB 28dB 30dB 32dBGPON2、仪器仪表 ⑴OTDR ⑵光源及光功率计 3、测试方法 对光纤线路的测试分两部分:分段衰减测试和全程衰减 测试 ⑴.采用 OTDR 对每段光链路进行测试。测试时将光分 路器从光线路中断开,分段对光纤段长逐根进行测试,测试 内容包括在 1310nm 波长的光衰减和每段光链路的长度,并 将测得数据记录在案,作为工程验收的依据。 ⑵ . 全程衰减测试采用光源、光功率计,对光链路用 1310nm、1490nm 和 1550nm 波长进行测试,包括活动光 连接器、光分路器、接头的插入衰减。同时将测得数据记录 在案,作为工程验收的依据。测试时应该注意方向性,即上行方向(ONU 往 OLT 机房端)采用 1310nm 测试,下行方 向(OLT 机房往 ONU 端)采用 1490nm 和 1550nm 进行测 试。不提供 CATV 时,可以不对 1550nm 进行测试。 对下行方向测试时将光源调整到下行波长恒定功率输 出,连接在 OLT 所在机房 ODF 架相应光纤上,持光功率计 至终端光分线盒逐芯测试并做好记录。对上行方向测试时, 将光源调整到上行波长恒定功率输出,分别连接至终端光分 线盒相应光纤,光功率计连接在 OLT 所在机房 ODF 架相应 光纤上测试并做好记录。 ODN 全程损耗=光源发光功率-光功率计读数 ㈢ONU 测试 测试内容:ONU 发光功率 1、ONU 参数指标:(单位:dBm) ONU 平均发射功率 最大接受灵敏度 2、测试方法 设备加电稳定工作后,用光功率计逐端口测试。 九、附则 1000BASE-PX20-U -1~+4 -24 1000BASE-PX10U -1~+4 -24本标准中与国家相关规范、 标准不一致的以国家相关规 范、标准为准。

FTTx 施工工艺标准目录FTTx 施工工艺标准(讨论稿)............................................................................................... 1 一、 二、 ㈠ ㈡ 总则 ........................................................................................................................ 3 局端设备安装 ........................................................................................................ 3 局端设备布局规划 ................................................................................................ 3 局端端设备安装标准 ............................................................................................ 4四、ODN 建设 ...................................................................................................................... 6 ㈠ODN 层次结构 .............................................................................................................. 7 ㈡ODN 规划 ...................................................................................................................... 7 ㈢PON 口容量规划 ........................................................................................................... 9 五、光缆线路施工 ............................................................................................................... 9 ㈠ ㈡ ㈢ ㈣ 光缆线路敷设 ...................................................................................................... 10 光缆线路防护 ...................................................................................................... 16 引上及引入 .......................................................................................................... 18 接地 ...................................................................................................................... 20㈤接续与成端 ................................................................................................................. 20 六、分线设备安装 ............................................................................................................. 21 ㈠ODF 设备安装 ............................................................................................................. 21 ㈢ ㈣ 交接箱安装 .......................................................................................................... 23 分线盒安装 .......................................................................................................... 25七、ONU 设备安装 ............................................................................................................ 26 ㈠ 综合配线箱安装 .................................................................................................. 26㈡ONU 安装 .................................................................................................................... 26 ㈢电源引入 ..................................................................................................................... 27 ㈡ 接地防护 .............................................................................................................. 27八、测试 ............................................................................................................................. 27㈠光缆测试 ..................................................................................................................... 27 ㈡OLT 测试 ...................................................................................................................... 28 ㈢ODN 测试 .................................................................................................................... 28 ㈢ONU 测试 .................................................................................................................... 30 九、附则 ............................................................................................................................. 30一、总则1、 参 照 《 公 用 计 算 机 互 联 网 工 程 设 计 规 范 》 ( YD 5037-2005 ) 、 《公用计算机互联网工程验收规范》 ( YD 5070-2005) 、 《中国移动 PON 网络工程施工及验收规范》 (QB-G-001-2011)制定本工艺标准、 《铁通公司宽带优质 网络实施指导意见(试行) 》 。 2、 本标准为建设的工艺标准,不包括经济指标。 3、 建设的网络应具有可运行性、可管理性、可增值性 和可扩充性。 4、 本标准适用以 FTTx 方式的宽带接入网的建设。 5、 施工前对施工使用的器材要进行检验,技术指标满 足《大楼通信综合布线规范》 (YD926.1~3-2009 )系列标 准要求,不合格的器材严禁使用。 6、 在施工过程中执行本标准特别困难时,应充分论述 理由,并报请建设单位批准。 二、 局端设备安装机房要符合《公用计算机互联网工程验收规范》 (YD/ T 5070- 2005)有关标准。 ㈠ 局端设备布局规划 根据工程经验,建议大中城市客户密集区域半径可按照2~5 公里规划,城市其他有业务需求的区域可按照 5~10 公里规划,城市郊区或乡镇可按 10 公里左右规划,但 OLT 的具体覆盖范围需要根据实际情况确定。 以单局点用户 (指 ONU 的以太网端口数或 ONT 的个数) 规模不低于 2000 户为原则来设置 OLT 的数量。 ㈡ 局端端设备安装标准 1. 机架设备 ⑴机房内机架设备的平面位置、机面朝向、机架相互距 离应符合工程设计要求。 ⑵机架设备安装应端正牢固。机架设备安装必须按设计 所要求的抗震加固措施进行加固,并符合有关的通信设备安 装抗震设计规范。 ⑶机架安装后各直列上、下两端垂直倾斜误差应不大于 3mm。 ⑷除有特定的绝缘隔离、散热、电磁干扰等要求外,机 架应紧密相互靠拢。 ⑸列间距离与设计的误差应不大于 5mm 。主走道侧必 须对齐成直线。列内机面平齐,无参差现象,机面对齐误差 不大于 5 mm。 ⑹机架及机架内设备的所有紧固件必须拧紧,同类螺丝 露出螺帽的长度应一致。⑺机架上的各种零件不得脱落或碰坏,漆面如有脱落应 予补漆。各种文字和符号标志应正确、清晰、齐全。 ⑻机架必须按施工图的抗震要求进行加固。 ⑼告警显示单位安装位置端正合理,告警标示清楚。 2、子架安装 ⑴面板布置应符合设计规定。 ⑵子架与机架的加固应符合设备装配要求。 ⑶子架安装应牢固、排列整齐,插接件接触良好。 ⑷子架安装完毕应按建设方要求做好标识。标识应统 一、清楚、明确,位置适当。 3 、电缆走道、桥架安装要求 ⑴电缆走道、桥架的安装位置、高度应符合工程设计要 求,偏差不得超过 50mm。 ⑵电缆走道、桥架扁钢平直,无明显扭曲和歪斜。 ⑶安装好的电缆走道、桥架应平直,各横铁规格一致, 两端紧贴走道扁钢和 横铁卡子,横铁与走道扁钢相互垂直, 横铁卡子螺钉紧固。 ⑷横铁安装位置应满足电缆下线和做弯要求,横铁排列 均匀。当横铁影响光 缆曲度半径时,可做适当调整。 ⑸电缆走道的地面支柱安装应垂直稳固,允许垂直偏差 为 1.5‰; 同一方向 的立柱应在同一条直线上, 当立柱妨碍 设备安装时,可适当移动位置。⑹沿墙水平电缆走道应与地面平行,沿墙垂直电缆走道 应与地面垂直。 ⑺ 电缆走道穿过楼板孔或墙洞的地方,应加装子口保 护。电缆放绑完毕后, 应有阻燃材料封堵。 ⑻ 列间撑铁的安装应在一条直线上,两端对墙加固应 符合设计要求。 ⑼ 吊挂安装应牢固、整齐,保持垂直,吊挂构件与电 缆走道漆色一致。 ⑽铁件的漆面应完整无损,如需补漆,其颜色与原漆色 应基本一致。 ⑾ 安装沿墙单边或双边电缆走道时,在墙上埋设的支 持物应牢固可靠,沿水平方向的间隔距离均匀。安装后的走 道应整齐一致,不得有起伏不平或歪斜现象。 ⑿安装走道应符合下列规定: ①水平走道应与列架保持平行或直角相交,水平度每米 偏差不超过 2mm。 ②垂直走道应与地面保持垂直并无倾斜现象,垂直度偏 差不超过 3mm。 ③走道吊架的安装应整齐牢固, 保持垂直, 无歪斜现象。四、ODN 建设㈠ODN 层次结构 ODN 主要分为主干层、配线层和引入层三个层次。 主干层:系指机房至主干光缆交接箱之间的光网络,包 括机房 ODF 架至主干光缆交接箱的光缆及配线设备。 配线层:系指主干光缆交接箱至用户住地网交接箱第一 级分光器之间的光网络。包括主干光缆交接箱至用户住地网 交接箱间的光缆及配线设备。 引入层:系指用户住地网交接箱第一级分光器至引入用 户所在楼内最靠近用户侧光缆分线箱 (FTTB 方式时的 ONU 机箱)之间的光网络。包括分光器至末端分线设备之间的光 缆及分光、配线设备。 引入用户室内的光缆为综合布线。 ㈡ODN 规划 在 PON 网络的部署中,分光器放置根据用户以及局方 机房的分布有不同的方式。不管采用何种方式,放置分光器 尽量做到以下几条原则: 1、便于日后的维护管理 2、提高分光器端口的使用率 3、节约投资,减少光缆使用量 4、便于网络的升级 以下是 PON 网络中几种典型的分光器放置:1、分光器集中分光集中放置(1 级分光)⑴分光器集中放置在中心机房(靠近 OLT) 采用该组网结构一般来说中心机房与用户侧的距离比 较近,这里中心机房也可以是小区机房,小区住宅用户密度 一般也较高。 ⑵分光器集中放置在用户侧(靠近 ONU) 中心机房与用户侧的距离比较远,但用户密度较高。用 户侧一般为可以放置多个分光器的室外光分配箱或交接箱, 也可以是大楼内的 ODF 架 2、分光分散放置(1 级分光) 这种 PON 网络结构中机房与用户的距离比较远,用户 数不是非常密集。用户侧为可以容纳 1 个分光器室内型的光 分配箱。 该 PON 的网络结构实际上和分光器集中放置在用户侧 本质上是一样的。 3、分光器分散放置(2 级分光) 2 级分光可以有多种组合,典型的组合 EPON:1:4×1:8, 1:2×1:16 GPON :1:4×1:8,1:8×1:8 , 1:4×1:16 第 1 级分光器可以集中放置在中心机房或者光交接箱 里,也可以分散放置在接头盒里。第 2 级分光器放置在靠近用户侧分线盒内。 ㈢PON 口容量规划 在光功率预算满足的情况下, PON 口所能接入的用户数 要综合考虑用户业务带宽需求和光分路器的分光能力。 用户带宽规划法:单个 PON 口下接入用户数=PON 口 下行带宽×带宽冗余系数/(用户承诺带宽×用户并发率×流量 占空比) 。 分光比规划法:单个 PON 口下接用户数=总分光比× ONU 以太网口数(或 ONT 个数) 。 PON 口下行容量取两种方法计算值较低的作为规划参 考。 五、光缆线路施工 敷设工艺必须符合 YD5102-2010 《通信线路工程设计规 范》和 YD/T5121-2010《通信线路工程验收规范》的要求。 余留长度及弯曲半径标准见下表: 光缆预留长度要求及增长参考值项目 接头处每侧预留长度 地下局站每侧预留长度 地面局站内每侧预留长度 敷设方针 直埋 管道 架空 5~10m 5 ~ 5~10m 10m 5~lOm。 可拨实际需要适当调 整 1O~20 m。 可按实际需要适当调整 因水利、道路、桥梁等建设规划导致 按实际需要确定 的预 因接入中间人孔预留 根据需要光缆最小弯曲半径标准光缆外护层形式 静态弯曲 动态弯曲 无外护层 04 型 53 、 54 、 33 、 34 333 型、 43 型 型 10D 12.5D 15D 20D 25D 30DD-光缆外径 光缆线路与其它建筑物的要求应符合 YD/T5121-2010 《通信线路工程验收规范》附录 C “光缆线路与其他建筑设 施的间距”的要求。 ㈠ 光缆线路敷设 1、 架空敷设 ⑴架空光缆敷设后应自然平直, 并保持不受拉力、 应力, 无扭转,无机械损伤。 ⑵架空光缆垂度为吊线原始垂度、光缆结构重量及架挂 方式多方面因素形成。应符合 YD/T5121-2010《通信线路工 程验收规范》的要求。 ⑶光缆挂钩的间距应为 500 mm,允许偏差士 30 mm。 挂钩在吊线上的搭扣方向应一致,挂钩托板应安装齐全、整 齐。 在电杆两侧的第一只挂钩应各距电杆 250 mm ,允许 偏差士 20mm。见下图光缆的挂钩程式应根据设计要求选用,详见下表:光缆 直径 光缆 挂钩 程式 (mm) 32 以上 65 32 以下 55 24 以下 45 18 以下 35 12 以下 25⑸布放吊挂式架空光缆应在每 1~3 根杆上作一处伸缩 预留。伸缩预留在电杆两侧的扎带间下垂 200mm 伸缩预留 安装方式应符合下图的要求。光缆经十字吊线或丁字吊线处亦应安装保护管。符合下 图要求:⑹ 架空光缆在吊线接头处的吊扎方式应符下图的要 求。⑺架空光缆接头盒应固定在距电杆 1.5 米处,接头盒应 使用紧固件与钢绞线之间固定牢固。为防盗可使用扎线捆扎 3~5 圈。 ⑻一般情况下,光缆跨越公路要套反光管, 吊线跨路与路 面距离大于 5.5m。 ⑼在电杆的一侧及十(丁)字交叉处应安装光缆标识挂 牌。2、 管道敷设 敷设管道光缆的孔位应符合设计要求。 ⑴在孔径 90mm 及以上水泥管道、钢管或塑料管道内, 应根据设计规定在两人(手)孔间一次性敷设三根或三根以 上的子管。 ⑵子管不得跨人(手)孔敷设,子管在管道内不得有接 头。 ⑶子管在人(手)孔内伸出长度一般为 200~400mm; 本期工程不用的管孔及子管管孔应及时按照设计要求进行 封堵。光缆敷设前应按“8”字盘放,管井边缘要做好保护,防 止光缆外皮被刮破。敷设应符合下列要求: ⑷应按设计要求的 A、B 端敷设光缆。 ⑸敷设光缆时的牵引力应符合设计要求。 ⑹光缆在各类管材中穿放时,管材的内径应不小于光缆 外径的 1.5 倍。⑺光缆出管孔 150mm 以内不得做弯曲处理。 ⑻管道光缆根据接入需要按设计要求进行中间人孔预 留。光缆余长应在人孔内盘放并固定。 ⑼敷设后的管道光缆在人(手)孔内应排列、固定整齐。 光缆在人(手)孔内子管外的部分应按设计要求保护。 ⑶管孔及子管管孔均应按设计要求的材料进行堵塞。 ⑾光缆在每个人孔内按要求做好标识。如下图:3、直埋敷设 直埋光(电)缆埋深应满足通信光缆线路工程设计要求的 有关规定,具体埋设深度及与其他建筑设施平行或交越时的 最小净距应符合YD/T5121-2010《通信线路工程验收规范》 的要求。 4、沿墙敷设 ⑴吊线式墙壁光缆使用的架设材料规格应符合附录 H 的要求。 ⑵钉固式墙壁电缆选用的卡钩应与光缆外径(或光缆保护管外径)相匹配,当采用金属卡钩时,光缆在卡钩处应采 用塑料管防护。 ⑶末端和转弯处两侧采用双卡购固定。 ⑷末端、分歧、转弯及引入处应挂设光缆标识。 ⑸敷设标准应符合 YD/T5121-2010 《通信线路工程验收 规范》6.4 的要求。 5、槽(过)道内敷设 ⑴槽(过)道内敷设光缆时,要将光缆绑扎在内部支架 上,光缆要平直,弯曲半径符合规范要求。 ⑵在桥梁等震动较大的槽道内敷设光缆时应采取防震 措施。 ⑶同一槽道内敷设多条光缆时,各条光缆应顺向排列, 不应有交叉。 ⑷槽(过)道内敷设的光缆不应采用铠装或油麻外被层 光缆。 ⑸引出槽道时,与槽壁的交叉处应采取防护措施。 6、蝶形光缆敷设 ⑴蝶形光缆程式应与采用的敷设形式相适应。 ⑵在槽道内敷设时参照在槽道内敷设光缆时的标准。 ⑶在引户内且采用明布时,宜使用卡钉钉固,卡钉距离 宜为 400mm。 ⑷引入用户户内采用线槽敷设时,线槽应横平竖直。⑸引入用户户内的敷设位置及敷设方式应事先值得用 户同意。 ㈡ 光缆线路防护 1、 直埋光缆在跨越城市主干道及主要公路时,应采用 钢管防护,保护管起止点在路基两侧排水沟外应≥1 m. 保护 管埋深应大于排水沟永久沟底以下 500 mm。在跨越城市次 干道以下及乡村公路时可采用硬质塑料管防护,其长度和埋 设深度与钢管同。 2、 受地形影响埋深达不到要求时,应采取防护措施。 防护可采用水泥槽、复合材料防护槽、硬质塑料管或钢管。 3、 架空光缆跨越道路时除距离路面净间距应满足要求 外,还应加挂标志牌。 4、 沿墙敷设的转弯处,墙角处于转弯的弯内时,转弯 处应采用塑料管防护。 5、 架空及沿墙敷设时的余留光缆应盘成圆圈,并固定 在十字盘留架中,然后固定在吊线或墙壁上。圆圈的半径不 得小于规范规定的弯曲半径。 6、 光缆穿越墙壁时,墙洞内应采用塑料管防护。墙洞 两侧应留有滴水弯。 7、 采用管、槽防护时,管、槽应横平竖直。管、槽应 尽量贴近楼顶, 一般情况下距离天花板距离不应大于 50mm,沿楼梯斜坡敷设管、槽时,管、槽应与楼梯的斜坡平行。管、 槽接头处应采用相应型号的接头材料对接。槽底每间隔 0.5~1m 钉固一个钢钉,每根槽底两端在距端头 100mm 处 必须钉固一个钢钉。两根塑料槽直通连接时,可错开槽底与 槽盖的接头位置直接连接,而不采用专用接头。塑料管防护 时,所选用的卡钩应与管径相适应,每间隔 400 ~500mm 钉固一个卡钩。 8、 管道内的余留光缆盘成圆圈固定在人孔壁上的支架 上,不得平放在人孔底部。 9、 光缆接头处两侧金属构件不作电气连通。 10、 局站内的光缆金属构件应接防雷地线。 11、 光缆在桥上敷设时,应考虑机械损伤、震动和环 境温度的影响,并采取钢管或塑料管等相应的保护措施。 12、 吊挂式架空吊线与电力线交越时,一般应从电力 线的下方通过,与电力线交越部分的架空吊线应外套电力线 保护管。吊线与电力线间距应符合 YD/T5121-2010《通信线 路工程验收规范》附录 C 的要求。安装的电力线保护管的 材质、规格、长度应满足设计要求。 13、 光缆在不可避免跨越邻近有火险隐患的建筑设施 时,应采取防火保护措施。㈢ 引上及引入 引上钢管上端 口距离地面间距不 应小于 2.5m, 引上 管的上、下端应固 定在电杆或墙壁 上。引上管上端口 应密封。 1、 沿 电 杆 引 上。 ⑴ 露出引上管的垂直部分光缆应采用塑料管防护。⑵ 引上光缆在露出引上管 150mm 处开始进行绑扎,向上每 间隔 500mm 进行一次绑扎, 最上端距水平吊挂光缆 150mm 处做一次绑扎。如上图所示。 2、 沿 墙 引上。 ⑴ 在 距 引上管上端口 和地面处对引 上管进行固定。 ⑵ 引 上 后沿墙引入机 房时, 在引人口 处应留滴水弯。 ⑶ 露 出 引上管部分应 采用塑料管防 护。 3、 引入 ⑴ 光缆在地上引入室内时,光缆在墙洞内引采用塑料 管防护。 ⑵ 在墙外侧应留滴水弯,防止雨水沿光缆流入室内。⑶ 引入光缆后应将墙洞全部密封。交接箱引入光缆后 其所有引入孔应密封。 ⑷ 光缆引入箱盒时, 箱盒的引入口边沿应塑胶圈防护, 防止箱盒金属壁伤害光缆 ⑸ 光缆引入交接箱后,其加强芯应牢固固定到交接箱 的固定件上,其外护套的开拔边沿应用塑料胶带包扎。 ⑹ 交接箱门与箱体之间应采取密封措施。 ⑺ 所有箱盒都要加锁。 ⑻ 所有光缆引入点都应挂标志牌。 ㈣ 接地 一般地段,采用电悬浮方式进行防涝及防强电,即光缆 在接续时金属加强芯两端既不连接也不接地,但在接续操作 过程中采取临时接地措施,接续完成后拆除。在强电干扰严 重地段采用全介质光缆。 ㈤接续与成端 1、 光缆接续与成端 ⑴ 光缆接续前应核对缆的端别、纤序,接续后不得 出现纤序错接。光缆端别及纤序应作识别标志。 ⑵ 直埋光缆的接头应选择在地势平坦和地质 稳定的地点,应避开水塘、河流、沟渠及道路等;管道光缆和架空光缆的接头应避开交通要道口 ; 架空光缆 的接头应落在杆上或杆旁 1~1.5m 左右的位置。 ⑶热可缩套管热缩后应外形美观,无变形,无槽皱,无 烧焦,无喇叭口,熔合处无空隙、无脱胶、无杂质等不良状 况。 ⑷ 光缆接头盒密封后应保持良好的水密性和气密性。 ⑸ 热可缩管应套入编号后全部顺序卡入托盘的卡槽内。 ⑹ 光纤应留在托盘内,不能与热可缩太高叠压。 ⑺应把填有接续日期、天气、温度、每纤的接续推断损 耗、接续人员姓名等资料的接续卡片放置在接头盒内。 2、蝶形光缆成端 蝶形光缆敷设时采用整段光缆敷设,中间不应有接头。 成端时采用适配器在蝶形光缆上直接成端,禁止在蝶形 光缆上接续尾纤的方式成端。 六、分线设备安装 ㈠ODF 设备安装 1、机架安装 参照局端设备机架安装部分。 2、子架安装 参照局端设备子架安装部分。 3、其它要求⑴安装在光纤(总)配线架内同一层的一体化单元框应 在同一平面上,同一列一体化单元框应在同一垂直线上。同 一框内的一体化托盘应无凹凸现象。 ⑵光纤终端单元的安装应符合下列要求: ①同一层光纤终端单元应在同一平面上,同一列光纤终 端单元应在同一垂直线上。 ②光纤终端单元转动灵活。 ③光纤终端单元转动时不应抻拉设备光缆和跳纤。 ⑶光纤(总)配线架走纤槽道的安装应符合以下要求: ①各架之间的走线槽道应连接固定。 ②固定走线槽道的螺栓不得对光跳纤造成损伤。 ⑷跳纤的敷设应符合以下要求: ①光纤的选型及结构应符合设计要求。 ②跳纤选用的连接器插头类型应与线路侧一体化单元 框和设备侧终端单元上的适配器匹配。 ③跳纤的布放应整齐,并应根据光纤总配线架的类型走 一定的路由,不得混乱。架内跳纤与架间跳纤应分别走线, 先布放架内跳纤,后布放架间跳纤。 ③储纤长度不宜超过 1m,以最大限度地减少架内冗余 光纤。 ⑤根据光路性质选择跳纤的颜色,并满足各运营商的要 求。㈢ 交接箱安装 交接箱的安装方式、地点与型号应符合设计要求。箱体 无变形、掉漆等现象。 1 落地安装 ⑴采用落地方式安装时,交接箱应安装在预先制作好的 底座上。 ⑵ 安 装 底 座 边 沿 应 比 交 接 箱 底 部 边 沿 大 出 50 ~ 200mm。 ⑶安装底座边沿应比交接箱边沿底 10~20mm 并做成 漫坡,防止底座顶部积水。 ⑷交接箱应牢固的固定在底座上。 ⑸用砖砌底座时,底座表面应抹一层水泥沙浆。 安装完成后如下图所示2 壁挂安装 交接箱四角用膨胀螺栓固定在墙壁上,立沿应与地面垂 直, 偏差不应大于 1°。 交接箱下沿距地面不应小于 1500mm。 3 光缆引入 光缆引入后交接箱的引入口和引入管的端口都应封堵。 沿墙敷设光缆引入壁挂式交接箱时,在引入口处应留滴水 弯,多条光缆同时引入时光缆应排列整齐,引入口处应采用塑胶圈防护。 室外壁挂安装时光缆不得在上部引入。 4 接地防护 箱体的接地应满足设计要求。 5 标识 ⑴ 箱体标识 箱体正面左上部喷涂(粘贴)企业标识,在箱体右下部 喷涂(粘贴)编号。编号一般由 3 部分组成:第 1 部分标识 区域(由 2 个汉字组成) ,第 2 部分标识箱盒的类别(由 1 个字母组成) ,第 3 部分为顺号(由 3 位数字组成) 。 ⑵ 光缆标识 ①光缆标识 在光缆上挂标志牌,标识光缆的型号,去向,长度。 ②配线标识 跳纤应粘贴标签,标明跳纤用途。 ㈣ 分线盒安装 1、 安装 盒体应牢固固定在墙壁上,立沿应与地面垂直,偏差不 应大于 1°。 2、标识 ⑴盒体标识盒体正面上部标识喷涂 (粘贴) 企业标识, 下部喷涂 (粘 贴)编号。盒体距地面不应小于 1500mm。 ⑶ 配线标识 引入户内的配线粘贴标签,标识去向。 七、ONU 设备安装 ㈠ 综合配线箱安装 1、 安装 ⑴室外安装时应采用带防雨沿的箱体或采取防雨措施 ⑵盒体应牢固固定在墙壁上,立沿应与地面垂直,偏差 不应大于 1°。箱体下沿距地面应≥1500mm。 ⑶体内配线应理顺并绑扎。 ⑷室外安装时光缆不得在上部引入 2、 标识 体正面左上部喷涂(粘贴)企业标识,在箱体右下部喷 涂(粘贴)编号。编号一般由 3 部分组成:第 1 部分标识区 域(由 2 个汉字组成) ,第 2 部分标识箱盒的类别(由 1 个 字母组成) ,第 3 部分为顺号(由 3 位数字组成) 。 ㈡ONU 安装 ONU 应牢固固定在综合配线箱的固定架上。 其 RJ45 接 口朝向应便于插拔网线。㈢电源引入 电源引入机箱时及在箱体内应与电缆分开, 敷设的电源 线应采用塑料管防护。 ㈡ 接地防护 ⑴ 接地防护应符合设计要求。 ⑵在有等电位体的楼内安装时其接地线可连接至大楼 的等电位接地体。 ⑶各接地线都应直接连接至汇流排上 八、测试 ㈠光缆测试 1、 单盘测试 光缆运至施工地点后应进行单盘测试, 波长范围: 上行:1260~1360nm 下行:1480~1500nm (CATV:1550nm) 2、竣工测试 ⑴接续损耗测试 采用 OTDR 冲出每个接续点的接续损耗并做好记录。 ⑶ 户光缆测试用光源光功率计测出每条用户光缆的总损耗并做好记 录。 ㈡OLT 测试 测试内容:OLT 发光功率 1、OLT 参数指标:(单位:dBm) GEPON GPON ClassB+ 平均发射功率 最大接受灵敏度 波长范围: 上行:1260~1360nm 下行:1480~1500nm (CATV:1550nm) 2、测试仪表 光功率计 3、测试方法 OLT 设备加电稳定工作后,用光功率计逐端口测试。 ㈢ODN 测试 测试内容:ODN 全程损耗 1、网络参数 ODN 网络 (物理媒体独立层)的参数 1.5~5 -28 GPON-PX 20 +2~+7 -27 EPON-PX 10 -3~+2 -24设备类 型 EPON最大允许衰减 光器件类型 1000BASE-PX20 1000BASE-PX20+ CLASS B CLASS B+ CLASS C CLASS C+ 上行: 1310nm 下行:1490nm 24dB 28dB 25dB 28dB 30dB 32dBGPON2、仪器仪表 ⑴OTDR ⑵光源及光功率计 3、测试方法 对光纤线路的测试分两部分:分段衰减测试和全程衰减 测试 ⑴.采用 OTDR 对每段光链路进行测试。测试时将光分 路器从光线路中断开,分段对光纤段长逐根进行测试,测试 内容包括在 1310nm 波长的光衰减和每段光链路的长度,并 将测得数据记录在案,作为工程验收的依据。 ⑵ . 全程衰减测试采用光源、光功率计,对光链路用 1310nm、1490nm 和 1550nm 波长进行测试,包括活动光 连接器、光分路器、接头的插入衰减。同时将测得数据记录 在案,作为工程验收的依据。测试时应该注意方向性,即上行方向(ONU 往 OLT 机房端)采用 1310nm 测试,下行方 向(OLT 机房往 ONU 端)采用 1490nm 和 1550nm 进行测 试。不提供 CATV 时,可以不对 1550nm 进行测试。 对下行方向测试时将光源调整到下行波长恒定功率输 出,连接在 OLT 所在机房 ODF 架相应光纤上,持光功率计 至终端光分线盒逐芯测试并做好记录。对上行方向测试时, 将光源调整到上行波长恒定功率输出,分别连接至终端光分 线盒相应光纤,光功率计连接在 OLT 所在机房 ODF 架相应 光纤上测试并做好记录。 ODN 全程损耗=光源发光功率-光功率计读数 ㈢ONU 测试 测试内容:ONU 发光功率 1、ONU 参数指标:(单位:dBm) ONU 平均发射功率 最大接受灵敏度 2、测试方法 设备加电稳定工作后,用光功率计逐端口测试。 九、附则 1000BASE-PX20-U -1~+4 -24 1000BASE-PX10U -1~+4 -24本标准中与国家相关规范、 标准不一致的以国家相关规 范、标准为准。


相关内容

  • 6.1企业研究开发活动说明书-参考4
  • 深圳市XXXXX有限公司 研究开发情况介绍 第一部分 公司简介 深圳市XXXXX有限公司成立于2008年12月1日,是一家民营企业,地址位于深圳市XXXXXX,建筑面积1780 平方米,其中净化生产车间面积900 平方米,化库房面积300平方米,办公区域为400平方米.公司注册资金为800万元,其中 ...

  • PLC平面光波导分路器
  • 深圳市特发信息股份有限公司 PLC 平面光波导分路器产品介绍 随着电信市场新增值业务如网络视频可视电话.IPTV .网络游戏.网络教育 等的不断推出,用户对带宽的要求不断提高,现有以铜缆为主的XDSL 网络已不能 适应用户的需求.世界各国特别是日本.韩国.美国等国家和地区已将FTTX 作为 接入网投 ...

  • 光纤技术再接入网中的应用毕业论文
  • 南京信息职业技术学院 毕业论文 作者 学号 51X2OX 系部 通信学院 专业 移动通信(3G技术与基站工程) 题目 光纤通信技术在接入网中的应用 指导教师 XXX 评阅教师 完成时间: 2013 年 5 月 15 日 毕业论文中文摘要 毕业设计外文摘要 目录 1引言 ............... ...

  • 无源光网络EPON技术浅谈
  • 随着ADSL.LAN.WLAN等宽带接入业务的大力发展,宽带业务已经零距离地深入到国计民生的各个角落.政府机关.企业机构.商业用户和越来越多的普通居民都已认可并广泛使用宽带业务.普通的高速上网.专网互联和互联网游戏业务是目前上网业务的主流.随着用户忠诚度的提高,开拓客户资源不再是宽带应用的唯一迫切要 ...

  • 杭州宽带差异化服务解决方案
  • 解决方案 宽带差异化服务解决方案 □江春雨 (四川通信科研规划设计有限责任公司 总工办,成都610041) 摘要: 本文通过分析互联网业务迅猛发展对运营商带来的机遇和挑战,提出宽带差异化服务在宽带接入.QoS .资源分配方面差异化的多种技术手段,说明在业务差异.服务差异的背景下,运营商可以抓住机遇, ...

  • 常用的网络接入方案及接入设备
  • 计算机网络 常用的网络接入方案及接入设备 学校:西南交通大学 学院:信息科学与技术学院 专业:软件工程 班级:软件二班 姓名:田杰雄 学号:20112740 常用的网络接入方案 1.ADSL ADSL (Asymmetric Digital Subscriber Line ,非对称数字用户环路)是一 ...

  • 宽带装维试题库
  • xxxx 家宽装维项目试题 公司:___ __ 区域: 姓名:___ _ 得分: ________ 一.单项选择题 1. 电源插座标签应使用( A ) A 淡黄色纤维纸 B 淡蓝色纤维纸 C 淡红色纤维纸 D 淡绿色纤维纸 2. 一级光缆(纤)线路用( B )什么表示 A 蓝底黑字 B 红底黑字 C ...

  • 主流宽带接入技术的特点及原理
  • 主流宽带接入技术的特点及原理 一. ADSL技术 1. 特点: ADSL技术的主要特点是可以充分利用现有的铜缆网络(电话线网络),在线路两端加装ADSL 设备即可为用户提供高宽带服务.ADSL的另外一个优点在于它可以与普通电话共存于一条电话线上,在一条普通电话线上接听.拨打电话的同时进行ADSL传输 ...

  • 系统开发科工作总结及下半年工作计划
  • 一、 结合全业务运营,调整团队人员工作内容与职责 结合全业务运营工作,2010年10月部门做了科室组织架构和分工的调整工作。为此,系统开发科于2010年2月对科室成员的工作内容进行了调整和优化,充分考虑到了全业务的工作内容和业务流程,以保证全业务的正常运营。   二、 做好项目规划管理,持续推进项目 ...