细丝直径测试仪

西安工业大学北方信息工程学院

课程设计(论文)

题目:细丝直径测试仪

学别:业:级:生:光电信息系光电信息工程B100105B10010511

李媛学号:任课教师:2013年10月

基于CCD 测量细铜丝直径系统设计

摘要

近年来,随着新型光电器件的不断涌现、单片机数据处理能力的提高和生产全面质量管理的要求,非接触式智能化仪器将逐步取代传统上的机械测量仪器本文设计了一套基于线阵CCD 的非接触直径测量仪器,该装置可以对φ0.5mm ~φ30mm 的工件进行测量,测量精度为±5μm 。本文论述了CCD 光电尺寸测量装置的基本原理,分析了光学系统各部分的形式,采用柯拉照明和远心光路成像,以保证成像质量和测量精度。用微分法提取被测工的边缘信息,详细论述了信号处理电路中的各个模块的实现方法,并将微分法处理电路和单片机控制系统作为重点。同时还给出了CCD 测量直径系统的控制程序流程图及部分程序。通过实验得到测量结果,对几个重要参数进行了分析,最后就影响系统测量精度的几种主要误差进行了讨论,给出消除误差的方法,以便达到更高的测量精度。关键字:线阵CCD 直径测量远心光路微分法MSP430

ABSTRACT

In recent years, along with new optoelectronic devices flowing out continuously 、the capacity of MCU data processing improving, and the requirements of overall production quality management, non-contact Intelligent machines will replace the traditional mechanical instruments gradually. In this paper, I designed a set of portable non-contact measurement instruments based on linear array CCD, which can measure the workpiece fromφ0.5mmto φ30mm,with measurement precision±5μm. In this paper, I discussed the basic principle of CCD photoelectric measurement devices, analyzed the form of parts of optical system, adopt Kohler illumination and telecentric beam path design in order to ensure image quality and accuracy. Adopting differential theory extracted edge information of measured workpiece, and discussed the signal processing circuit in the realization of the various modules in detail, and made the differential processing circuitry and single-chip control system as emphases, at the same time I gave control program flow chart of CCD diameter measurement system and related parts procedures of it. Through experimental measurement results, I analyzed several important parameters, discussed several major errors which influences the accuracy of system in the end, gave the method of elimination of errors, in order to achieve higher measurement accuracy.

Key Words:Line ararray CCD Diameter measurement

Telecentric optical path Differential theory MSP430

1录绪论.................................................................................................................. 5

1、1

1、2

1、3

1、4前言.................................................................................................... 5基于CCD 测径仪的发展现状国外发展现状.................................... 5国内发展现状.................................................................................... 6论文的主要内容................................................................................ 7

利用衍射法测量细铜丝直径............................................................ 7

利用分光法测量细铜丝直径............................................................ 8

线阵CCD 测量直径系统测细铜丝直径............................................ 9

成像系统.......................................................................................... 12

设计方案的论证与选择采用.......................................................... 13

整体系统设计.................................................................................. 13

光学系统设计.................................................................................. 14

3、2、1

3、2、2

3、2、3光源.................................................................................... 14光源照明............................................................................ 14成像光学系统.................................................................... 142测量原理和方案论证.................................................... 错误!未定义书签。2、12、22、32、42、53光学系统设计................................................................................................ 133、13、2

4精度分析........................................................................................................ 15

4、1光学系统对测量精度的影响分析.................................................. 15

4、1、1、衍射.................................................................................... 15

4、1、2、环境光扰动........................................................................ 15

4、2

4、3

4、4

4、5

4、6信号处理电路对测量精度的影响分析.......................................... 16零点漂移对测量精度的影响.......................................................... 16被测工件的均匀性对测量精度的影响.......................................... 16误差分析.......................................................................................... 16仪器误差.......................................................................................... 16

设计总结.......................................................................................... 17

学习体会.......................................................................................... 175总结................................................................................................................ 175、15、2

参考文献.............................................................................................................. 17

1

1、1前言绪论

光电自动检测技术在工业自动化生产中有着极其广泛和重要的用途。然而,目前产品零件尺寸的检测大多数是人工测量的接触式和静止测量,所以检测速度低,生产效率低,劳动强度大,远远跟不上目前自动化生产的需要。尤其在全面质量管理过程中,更需要先进的、智能的检测手段。目前,国内外常采用激光扫描光电线径测量[1~5],但是这种方法受电机的温度及振动的影响,扫描恒速度的限制,会产生高温使其降低寿命。我们研制的基于线阵CCD 便携式非接触直径测量仪器正是适应当前社会自动化生产的急需而设计的,该测径仪是一种光、机、电一体化的产品。尤其适用于电缆、电线、玻璃管、轴类零件的外径测量,对保证产品质量,降低原材料消耗,降低生产成本,提高劳动生产率有着重大的经济效益和社会意义

对各种细丝直径的测量常常关系到工业产品的级别,如钟表中的游丝、光导纤维、化学纤维、各种细线、电阻丝、集成电路引线以及种类仪器、标尺的刻线等。传统的测量方法多数为接触法,其它的有电阻法、称重法。也有采用光学方法的,如光学显微镜法、干涉法、扫描法、投影放大法、比较法等。然而,大多检测方法检测速度低,生产效率低,劳动强度大,远远跟不上目前自动化生产的需要。尤其在全面质量管理过程中,更需要先进的、智能的检测手段。目前,国内外常采用激光扫描光电线径测量,但是但激光衍射细丝测量法比较适合于静态的高精度测量,当用于动态测量时会由于被测丝的晃动导致衍射条纹快速移动而失准,也难以快速得到测量结果,同时还具有结构复杂、格昂贵等缺点,不太适于现场快速测量细丝直径。基于CCD 技术的快速发展及后续处理算法的日益真实有效故CCD 在现代自动化生产中扮演者越来越重要的作用。为满足大工业化生产线阵CCD 测径仪便应运而生,该测径仪是一种光、机、电、算于一体的产品。尤其适用于电缆、电线、玻璃管、轴类零件的外径测量,对保证产品质量,降低原材料消耗,降低生产成本,提高劳动生产率有着重大的经济效益和社会意义。1、2基于CCD 测径仪的发展现状国外发展现状

社会的进步重要体现就是科技的进步,科技进步主要体现使用劳动工具的进步。从18世纪工业革命以来,科学技术以前所未有的速度在突飞猛进的发展,特别是近50年来,随着现代化生产和加工技术的发展,对于加工零件的检测速

度与精度有了更高的要求,向着高速度、高精度、非接触和在线检测方向发展。为此,工业发达国家对于检测仪器与设备速度与精度一直作为检测仪器的主要指标。CCD 测径仪特别适用于电缆、电线的在线自动检测,对保证产品的质量,降低原材料消耗,降低生产成本,提高劳动生产率有着十分重要的意义,所以各国政府都很重视对测径仪的研究。英国Beta AS3系列全新的激光测径仪:LD1040-S(单向直径测量仪) 、LD1040XY-S(双向直径测量仪) ,精度:0.1μm ,测量范围最广,单向测径仪最大可测直径达330.3mm ,双向测径仪最大可测直径值达100mm ,测量精度最高,最高测量精度可达0.1μm ,是目前同类产品中的最高的测量精度。日本生产的LS-7000系列高速、高精度CCD 测量仪器,如:LS-7030M (配备测量摄影机)测量范围:0.3mm ~30mm ,测量精度:±2μm ,重复性精度:±1.5μm 。LS-7010M (配备测量摄影机)测量范围:0.04mm ~6mm ,测量精度:±0.5μm 。

1、3国内发展现状

国内由于自身的工业加工水平有限、测量原理的不完善和结构搭理欠合理,所以,国内生产的测径仪测量精度没有国外的精确,河北省激光研究所光电检测控制室生产的JCJ-1激光测径仪,是专为玻璃管生产线上玻璃管外径的测量、控制、分选而设计的集激光、精密机械、计算机于一体的智能化精密仪器。通过激光光束高速(200次/秒)扫描被测玻璃管,计算机实时采样处理,实现玻璃管直径在线非接触检测、控制,测量范围:0.5mm~60mm,测量精度:±0.01mm。广州一思通电子仪器厂生产的ETD-05系列激光测径仪,测量范围:0.2mm~30mm,测量精度:±2μm,ETD-05系列激光测径仪是一种基于激光扫描测量原理而设计的高精度非接触式的外径测量设备,仪器采用二维测量模式,有效消除工件振动造成的测量误差,特别适合生产现场的实时测量,适用于通信电缆、光缆、同轴电缆、漆包线、PVC管、铜管、纤维线等圆形线材的在线检测,也可用于其它各种圆形工件的外径测量。南京亿佰泰科技有限公司生产的TLSM100激光扫描测微仪,测量范围:0.2mm~30mm,测量精度:±3μm,是一种高精度、非接触的尺寸测量仪器。它通过激光束的扫描获得被测目标的尺寸,广泛用于测量热的、软的、易碎的以及其它传统方法不易测量的物体,而且很适合生产中的在线测量或者线材、棒材、管材、机械和电子元件以及其它生产过程的监控。TLSM100的自动方式适用于连续的测量;手动方式适合单次测量。它可以设置上下偏差、峰值限制,当超限后做相应的报警;还可以计算最大值、最小值、平均值。例如:可以测量旋转圆柱体的最大值、最小值,辊子的偏差。我们研制的基于线阵CCD 测径仪测量范围:0.5mm~30mm,测量精度:±5μm,适用于对被测工件进行静

态测量,也适用于生产现场的实时测量。

1、4论文的主要内容

(1)深入了解CCD,尤其是在线阵CCD 结构与工作原理的基础上,选择合理的线阵CCD,设计出合理的测量直径系统。对整个光电测量装置进行系统分析,包括CCD 所构成的测量直径系统的基本原理和输出信号处理电路。

(2)在进行光电测量装置设计时,对光学系统进行了详细分析,并用ZEMAX 软件设计柯拉照明系统中的集光镜、聚光镜和成像物镜。

(3)提出线阵CCD 测量方案:基于单片机的硬件测量法。单片机的硬件测量法是从CCD 出来的电信号经前置放大,滤波电路进行二值化处理,然后送入单片机,在经单片机处理后送入LED 显示。

(4)设计实验分别对几组直径应用上述方法进行测量,对测量结果进行比较、分析,同时对产生测量误差的主要原因给予分析

2、1利用衍射法测量细铜丝直径

我们选择了最简单的一种模型,它是常规的夫琅和费衍射。即把金属丝当成一个平面的狭缝, 其工作情况如图2-2所示。光源发出的平行光束垂直照射在单缝(金属丝) 上. 根据惠更斯-菲涅耳原理, 单缝上每一点都可以看成是向各个方向发射球面子波的新波源, 子波在接收屏上叠加形成一组平行于单缝的明暗相间的条纹. 和单缝平面垂直的衍射光束会聚于屏上x=0处, 是中央亮条纹的中心, 其光强为I0; 与光轴成θ角的衍射光束会聚于x=x(θ) 处, θ为衍射角, 由惠更斯-菲涅耳原理可

得光强分布

图2-1夫琅和费单缝衍射

sin 2u πD sin θI =I o , u =λ(2-1)

为式中D 为缝宽,λ为入射光波长.当θ=0时,I=I0,是中央主极大.当sinθ=kλ/D时,其中k=±1,±2,…,I=0,是暗条纹.由于θ很小,故sinθ≈θ,所以近似认为暗条纹出现在θ=kλ/D处.中央亮条纹的角宽度Δθ=2λ/D,其他任意两条相

邻暗条纹之间夹角Δθ=λ/D,即暗条纹以x =0处为中心.当使用激光器作光源时,由于激光的准直性,可将透镜L1去掉.如果接收屏远离金属丝(z>>D),则透镜L2也可省略.由于tgθ=x/z,且tgθ≈sinθ,则各级暗条纹衍射角应为sin θ=k λD =x

z (2-2)

由此可以求得金属丝直径为

D =kz λ

x k (2-3)

式中k 是暗条纹级数;z 为金属丝与测量平面间的距离;XK 为第k 级暗条纹距中央主极大的距离。

2、2利用分光法测量细铜丝直径

发光管D1发出的红外光经分光镜分成两路:测量光路和参考光路。测量光和参考光分别照射到两只相同型号的光电接收管T1、T2上。D1为中心频率880nm 的进口红外发光管; T1、T2为高一致性、线性度的进口光电三极管; 截止波长为850nm 的低通滤波片可有效地消除可见光干扰

图2-2分光法光路图

T2的输出电压分别为V 1和

V 1、V 2的差动电压值在测量光和参考光的照射下,T1和V 2, 在测量光路中没有被测细丝时, V 1=V 2, 此时

细丝直径d , 高度为检测窗口高度V i =0. 当测量光路有被测细丝时, 细丝在T1的检测窗口上产生一个宽度为h 的投射阴影, 导致V 1发生变化, 变化量ΔV 1与投射阴影面积d ・h 成正比; 由于在电路中采用了负反馈自动光强

调整技术, 使发光管发射的光强稳定不变, 此时V 2保持恒定值不变; 以V 2作基准, V 1、V 2的差动电压值V i =ΔV 1, 将V i 放大即可得到与被测细丝直径成线性关系的电压信号,

达到测量细丝直径的目的。

图2-3分光法原理图

2、3线阵CCD

测量直径系统测细铜丝直径

图2-4线阵CCD 测量直径系统结构图

被测工件被均匀照明后,经光学成像系统按一定倍率成像于线阵CCD 传感器上,基于线阵CCD 测量直径系统原理图如图2-5所示:

2-5线阵CCD 测量直径系统原理图

则在CCD 传感器光敏面上形成了被测工件的影像,这个影像反映了被测工件的直径尺寸,两者之间的关系由高斯公式表示为:

⎧l ' ⎪β=⎪d ' ⎪d =⎨β⎪⎪1-1=1⎪⎩(2-4)

其中:l-----物距

率l ′----像距f ′---像方焦距β----光学系统的放大d----被测工件的直径大小d ′---被测工件直径在CCD 上影像大小知道物距、像距并测出工件影像d ′的大小,即可求出被测工件的尺寸。

CCD 器件把光敏元上工件影像的光学信息转换成与光强成正比的电荷量。存储于MOS 电容中,用一定频率的时钟脉冲对CCD 进行驱动,则电荷定向转移到输出端。视频信号中每一个离散电压信号的大小对应着该光敏元所接收光强的强弱,而信号输出的时序则对应CCD 光敏元位置的顺序。最终,被测工件的影像大小反映在CCD 输出信号中变为输出信号电压的高低,即在CCD 中间被影像遮挡部分的光敏元输出电压低,两侧未被遮挡的光敏元输出电压高。CCD 的输出信号如图2-4所示

图2-6CCD 输出信号

最终由CCD 实现按空间域分布的光学图像信息向按时间域分布的电压信号转化,该输出电压信号经过信号处理后,可得到表示d ′大小的脉冲信号,脉冲信号送入单片机中,测出脉冲宽度,进而可求出被测工件的大小。即用CCD 复位脉冲(对应CCD 的光敏元)可求出尺寸的大小。若:δ为脉冲当量(CCD 脉冲),N 为CCD 器件像数,N1,N2为光照部分的光敏信号输出脉冲数,β为光学系统的放大倍数,则被测工件直径[7~9][12]为:D =[N -(n 1+n 2)]⨯δN ' ⨯δβ

=β(2-5)

本设计中δ=7μm ;N=5000;β=1,所以实际上被测工件直径尺寸为:

[5000-(n 1+n 2)]⨯7⨯10-3N ' ⨯7⨯10-3D ==11(2-6)

由于被测工件的边缘是通光和挡光的交界点,理论上该处的光强变化率最大,该点就是滤波后的视频信号电压函数v=v(t)在过渡区内的拐点,由高等数学知识知道,在拐点处,电压函数的一次微分为最大值,二次微分为零。基于以上原理,在测量系统中对CCD 输出信号采用微分法处理,便于寻找被测工件的边缘[10~11]。微分法的波形图如图2-7所示:

2-7微分法的波形

2、4成像系统

成像系统采用物方远心光路[10][13~20]。在光电检测中,常常在生产线上对工件进行动态测量或在实验室中进行静态测量,如测量钢丝直径、玻璃管直径或轴类零件等,为了提高测量精度,常采用远心光路和柯拉照明一起配合使用。对物体(工件)大小的测量,一般是将物体按一定倍率要求,经光学系统成像在CCD 的接收面上,然后对CCD

输出信号进行测量。

图2.8成像原理图

按照此种方法进行物体线性尺寸测量时,光电器件与物镜之间的距离应保持不变,其测量精度在很大程度上取决于像平面与光电器件接收面的重合程度。由于在测量过程中,工件常常会沿光轴方向有所移动,使像平面与光电接收面不可能真正重合,因而产生了测量误差如图2.8所示。图2.8中B1B2为被测物体;B1′B2′表示被测物体像的大小;M1M2为光电器件接收面,由于B1′B2′与M1M2二者不重合,使像点B1′B2′在M1M2上形成弥散班,在CCD 器件接收面上,实际测量像的大小为M1M2,显然它与实际的像长B1′B2′是不同的。这就使测量产生了很大的测量误差。为了消除这种误差,可以通过控制主光线的方向来达到,我们在设计成像物镜时选择了远心光路,如图2.9

所示:

图2.9物方远心光路

2、5设计方案的论证与选择采用

光学衍射法测量细铜丝直径在理论上已经很成熟,但实际应用中存在一定困难,特别是在测量精度提高时,其中的关键困难在于:当光经衍射后产生的衍射图样微弱,信号的信噪比比较低,还由于衍射图样的锐度不大,条纹位置不明显,给测量带来很大困难。特别是在实时动态测量过程中,造成测量结果不稳定,重复性差。而且本次测量的细丝直径为1mm ,在这个直径下不能形成明显的衍射条纹,即衍射法在原理上存在不足。

分光法在测量实质上是干涉法测量但也有不足:1、如果细丝有垂直于测量光方向的晃动, 且晃动的幅度使投射阴影超出检测窗口之外, 将会改变阴影面积进而产生较大的测量误差;2、光照在细丝上会产生微弱的衍射效应, 衍射会导致线性度变差;3、环境光扰动会降低信噪比, 影响测量精度;4、光电三极管对温度有一定的敏感性, 会随温度的变化而产生灵敏度的变化;5、分光法也不适合于与计算机的连接以及后续图像采集与处理保存。以上不足使得反光法对现代化自动化生产有一定的局限,但分光法在原理上不存在任何问题。

与同类测量系统比较,CCD 细丝直径测量系统具有测量速度快,测量精度高,抗干扰能力强等优良特点,是一种非接触式的测量系统,属无损伤测量,不影响加工系统正常运行,非常适合于生产线上尺寸的测量。该设计方案集成化程度高,可与计算机相联,可进行测量数据的集中采集和分析,以便进行质量分析和统计,并在生产过程中出现质量问题时进行报警提示,便于控制和自动化生产。

综合上述分析及我们小组的讨论研究,我们决定采用CCD 细丝直径测试仪的设计方案。

3

3、1整体系统设计光学系统设计

测量完整框图如图3-1所示。He-Ne 激光器发出的激光经反射镜M1、扩束系统M2后形成均匀的测量光,测量光经空间滤波器消除杂散光后入射被测量细丝,经光学系统在探测(CCD)上形成衍射条纹。CCD 将衍射图样转换为电信号经信号调整电路处理后进入计算机,处理采集到的信号,求得衍射图样中暗点的分布尺寸。为保证测量精度,消除细丝抖动带来的误差,CCD 的驱动电路要保证CCD 的积分时间足够短。

图3-1系统原理框图

3、2光学系统设计

3、2、1光源

测试中采用半导体激光器。半导体激光器又被称为二极管激光器(LED),是体积最小的激光器件,它结构简单坚固,便于直接调制。经过多年的发展,半导体激光器件的可靠性寿命从几分钟增加到百万小时,波长覆盖从中红外到近紫外,输出功率从豪瓦直到百瓦水平。半导体激光器工作物质是半导体材料,常用材料是砷化嫁,其结构原理与发光二级管类似。半导体激光器作为检测光源通常要求光源输出光强的稳定性好,引起激光光弧变化的因素有激光器电源稳定性的好坏、激光器的结构微小几何量变化以及它随工作时间的变化而产生的热变形与应力等。所以,激光器需要使用稳压电源。

3、2、2光源照明

由于半导体激光器有源层横截面的对称和很小的线度,半导体的远场光斑即不对称又具有很大的光束发散角,且发散角不同,垂直于结平面方向的发散角很大,一般高达50°,平行于结平面方向的发散角也有10°。所以应用半导体激光器的光学系统需考虑激光束的准直、像差的校正和椭圆光束的整形,因而需设计准直光学系统和整形光学系统。

3、2、3成像光学系统

由于生产线上细丝的摆动造成物距改变,从而使像平面与光电接受面不可能真正重合,带来测量误差。为消除其对测量的影响,提高测量精度,成像系统中我们采用物方远心光路,如图3-2所示

图3-2远心光路图

物方远心光路的基本原则为:在物镜的像方焦面处设置孔径光阑,即为物镜的出瞳,其入瞳位于无穷远处。物体上各点发出的光束经物镜后,其主光线必通过光阑中心所在的像方焦点F',而其物方主光线均平行于光轴。如果物体B1B2正确的位于与光电器件接受面M1M2共轭的位置A1,则在光电器件上像的长为M1M2。如果物体B1B2沿光轴有所移动,位置改到A2处,其像面B1'B2' 将与光电器件接受面不重合,而在光敏面上得到的是B1和B2弥散斑。但在物方空间,由于物体上同一点发出的主光线方向不变,其像方主光线必通过像方焦点F',因此光电器件接受面上的弥散斑中心仍通过M1M2点,从而提高了测量精度。

4精度分析

4、1光学系统对测量精度的影响分析

4、1、1、衍射

光照在细丝上会产生衍射效应,衍射会导致线性度变差。试验证明:在20um 以上,线性度是比较好的;在20um 以下线性度较差,但Vi 与d 的正相关关系没有改变,此时应采用值运算拟合法来提高精度。

4、1、2、环境光扰动

环境光扰动会降低信噪比,影响测量精度。在使用了滤波片后已滤除了大部分干扰光,再加上遮光罩可使环境光扰动忽略不计。

4、2信号处理电路对测量精度的影响分析

由于外界环境及电路自身元器件的不稳定性,会使得测量结果偏离理想状况。

4、3零点漂移对测量精度的影响

1、什么是零点漂移现象:ΔuI =0,ΔuO ≠0的现象。

2. 产生原因:温度变化,直流电源波动,器件老化。其中晶体管的特性对温度敏感是主要原因,故也称零漂为温漂。

3. 克服温漂的方法:引入直流负反馈,温度补偿。典型电路:差分放大电路4、4被测工件的均匀性对测量精度的影响

在生产过程中,轴类零件,电缆或电线的外径有时不很均匀。被测工件经过光照在CCD 成像,线径不等时则被照部分CCD 输出脉冲数与均匀被测工件被照部分的CCD 输出脉冲数不等,反应到测量结果上就会产生测量误差,在设计中,我们采用对被测工件的多次测量,然后求取平均值的方法来消除这种误差。粗大误差也影响测量精度,但它是有外界条件的突然变化引起的,当外界条件改变时引起CCD 输出信号的不稳定,只要保证外界条件持续稳定,则粗大误差就很少发生。

4、5误差分析

在实验过程中,我们分别对直径φ=1.0mm的标准件进行了三组测量,每一组采取多次重复测量,取平均值,并进行相应的精度计算。

4、6仪器误差

根据误差合成理论知仪器总误差为:)))∆系统∆+(∆+(∆)+(∆H es mt ∑222mm 2

5

5、1设计总结总结

本课题的研究是以线阵CCD--光电传感器TCD1501D 及光学镜头为基础构建的光学测量系统,对CCD 的输出信号采用微分法提取被测工件的边缘信息,由单片机对数据进行处理完成测量工作。本文从光学系统设计入手展开研究:包括测量直径系统的构建、线阵CCD 测量器件的选择、光学镜头的设计及实验研究,同时对系统组成的硬件电路、程序设计做了相应的介绍。综上所述,本课题的研究主要做了以下方面的工作:设计了基于线阵CCD 的直径测量系统。包括线阵CCD 的选型,光源的选取,光学镜头的设计,介绍线阵CCD 光学测量原理。在进行光电测量装置设计时,对光学系统进行了详细分析,并用ZEMAX 软件设计了柯拉照明系统中的集光镜、聚光镜和成像物镜。本论文从实验上实现了使用CCD 技术进行非接触测量,特别是对输出信号不采用传统意义上的阈值处理法,而采用微分法对工件的边缘信号进行提取,用MSP430F149单片机进行数据处理并编制相应的程序。用CCD 测径系统对几组直径做实验研究,分析了测量系统的误差。由测量结果可知,测量精度在±5μm 之内。如果从以下几个方面进行改进,可以得到更高的测量精度。

光学系统的设计、光学系统的准确调节、镜头装调和校验。测量时,若CCD 感光面与像面不重合,CCD 将接收到模糊的图像信息,造成测量误差,以后可以采用增加瞄准部分来解决。CCD 传感器的像元尺寸的几何位置精度高,可靠性高,寿命长,适合较恶劣的自然环境,CCD 技术被应用在几乎所有的成像相关的领域,随着科学技术的发展以及CCD 技术的研究和应用,CCD 技术将得到普及和推广。鉴于我小组成员的知识结构及经验有限,论文基于线阵CCD 便携式直径测量系统设计还存在许多不完善的地方,有待于在今后的研究中进一步完善。也希望学校在这方面对学生多给予实践上的帮助,脱离了实践的设计往往是个空中楼阁,想要真正把这些问题做到还得大家的共同努力。

5、2学习体会经过这次的课程设计,我个人得到了不少的收获,一方面加深了我对课本理论的认识,另一方面也提高了实验操作能力。现在我总结了以下的体会和经验。

这次的课程设计跟我们以前做的课程设计有所不同,因为我觉得这次我是真真正正的自己亲自去完成。所以是我觉得这次课程设计最宝贵,最深刻的。就是

课程设计的过程全是我们自己动手来完成的,这样,我们就必须要弄懂课程设计的要求。在这里我深深体会到哲学上理论对实践的指导作用:弄懂课程设计要求,而且体会到了课程设计的操作能力是靠自己亲自动手,亲自开动脑筋,亲自去请教别人才能得到提高的。

我们做课程设计绝对不能人云亦云,要有自己的看法,这样我们就要有充分的准备,若是做了也不知道是个什么课程设计,那么做了也是白做。课程设计总是与课本知识相关的,比如:此次的课程设计就必须回顾课本的知识,知道课程设计将要面对的难题、运用的什么物理量,写报告时怎么处理这些物理量。在课程设计过程中,我们应该尽量减少思路上的盲区以提高课程设计的效率,有的人一开始就赶着做,结果却越做越忙,主要就是这个原因。我也曾经犯过这样的错误。我们做课程设计不要一成不变和墨守成规,应该有改良创新的精神。实际上,在弄懂了课程设计原理的基础上,我们的时间是充分的,做课程设计应该是游刃有余的,如果说创新对于我们来说是件难事,那改良总是有可能的。比如说,在做课程设计时,我们可以通过不同思路、不同方法来解决。

在课程设计的过程中我们要培养自己的独立分析问题和解决问题的能力。培养这种能力的前题是你对此次课程设计的态度。如果你在课程设计这方面很随便,抱着等老师教你怎么做,拿同学的报告去抄,尽管你的成绩会很高,但对将来工作是不利的。

在这次的课程设计中,我对一些测试硬件、软件及其使用有了更深刻的认识。本人认为,在做这次的课程设计中,学习ZMAX 软件、光电仪器设计知识等知识,是一件很有趣的事情,因为ZMAX 软件是一个很好的软件,它能够对各种测试结果进行准确的分析实在是太神奇了,所以我觉得ZMAX 软件的起到非常重要的作用。

最后,通过这次的课程设计我不但对理论知识有了更加深的理解,对于实际的操作也有了质的飞跃。经过这次的课程设计,我们整体对各个方面都得到了不少的提高,希望以后学校和系里能够开设更多类似的课程设计,能够让我们得到更好的锻炼。

参考文献

1Harry prunk.The latest development in measuring equipment for online quality control at the cable extrusion[J].WireJournal International,2000,7:104~111.

2张国玉,安志勇,李成志等.双光束激光扫描尺寸测量系统[J].半导体光电,1998,5(16):320~323.

3邓景珊,张力,朱永茂等.核电站燃料2UO 芯块直径在线激光扫描测量[J].应用激光,2001,3(21):180~182.

4李慧鹏,王军,张军,唐文彦.一种新型非接触式线径测量系统[J].仪器仪表学报,2004,25(4):209~211.

5徐熙平,姜会林,张国玉著.光电尺寸检测技术及应用[M].吉林省科学技术出版社,2004,6~22.

5徐春梅.提高CCD 用于非接触式测量小精度的研究及其模拟实验.河北工业大学硕士学位论文,2000.1.

6康华光著.电子技术基础模拟部分[M](第四版).高等教育出版社,1987.8. 7佟首峰,阮锦,郝志航.CCD图像传感器降噪技术的研究[J].光学精密工程,2000,

8张林,李永新,胡学友.基于相关双采样的CCD 视频信号处理研究[J].宇航计测技术,2007

9黄美玲,张伯珩,边川平,李露瑶,达选福.相关双采样技术在航天相机中的应用研究[J].传感器技术,2005

10李艺琳,冯勇,安澄全.用相关双采样技术提高CCD 输出信号的信噪比

[J].电测与仪表,1999,第5期

11佐藤一郎著.集成运算放大器电路设计实用手册[M].学术期刊出版社,1989年第1版.

12费业泰.误差理论与数据处理[M].北京:机械工业出版社,199813郁道银,谈恒英主编.工程光学[M].机械工业出版社.

14吴福田,冯书文.CCD尺寸测量光学系统设计原理[J].应用光学,1994,15(5):20~22.

15王向军,王风华,周鑫玲.物像远心成像光路在高精度视学检测中的应用

[J].测试技术学报,1998,12(3):149~153.

16朴明波.对利用CCD 技术进行实时在线非接触式线径测量的研究.辽宁工程技术大学硕士论文,2003.12.

17孙学珠,付维乔,刘庆,王庆有.高精度CCD 尺寸自动检测系统的光学系统的设计[J].应用光学,1998,16(1):9~12.

18杨淋,周肇飞,张涛,晋崇就.线阵CCD 在高精度测量系统中照明选择[J].实用测试技术,2002,第5期,20~22.

19徐春梅.提高CCD 用于非接触式测量小精度的研究及其模拟实验.河北工业大学硕士学位论文,2000.1.

20康华光著.电子技术基础模拟部分[M](第四版).高等教育出版社,1987.8.

21张南洋生,张波,杨坤涛.一种变阈值二值化CCD 像元细分技术研究[J].半导体光电,2006,27(4):471~474.

22佟首峰,阮锦,郝志航.CCD图像传感器降噪技术的研究[J].光学精密工程,2000,8(2):140~145.

23张林,李永新,胡学友.基于相关双采样的CCD 视频信号处理研究[J].宇航计测技术,2007,27(4):33~37.

24Leonard Forbes,Harish Gopalakrishnan, and Weetit Wanalerlak. Analysis and simulation of noise in correlated double sampling imager circuits Proc of SPIE Vol 5844:238~247.

25黄美玲,张伯珩,边川平,李露瑶,达选福.相关双采样技术在航天相机中的应用研究[J].传感器技术,2005,24(8):31~33.

26李艺琳,冯勇,安澄全.用相关双采样技术提高CCD 输出信号的信噪比

[J].电测与仪表,1999,第5期,36(401):31~32.

27DALSA,Applications of high speed A/Din CCD imaging, DALSA 1996~1997DATABBOOK,1997.

28AD, analog device ,AD 1997~1998Databook,1997.

29许秀贞,李自田,薛利军.CCD噪声分析及处理技术[J].红外与激光工程,2004,33(4):140~145.

30佐藤一郎著.集成运算放大器电路设计实用手册[M].学术期刊出版社,1989年第1版.

31沈建华,杨艳琴,翟晓曙.MSP430系列16位超低功耗单片机原理与应用[M].清华大学出版社,2004年11月第1版.

32龙编著.MSP430单片机常用模块与综合系统实例精讲[M].电子工业出

版社,2007年7月第1版.

33光电自动检测原理及应用[M].长春光学精密机械学院,1981年.

34李永远,谢小平.CCD输出信号处理[J],应用光学,1997,(1):20~23.35杨博雄,胡新和,博辉清.CCD工作噪声分析与处理.光学与光电技术,2004;2(4):51~53.

36费业泰.误差理论与数据处理[M].北京:机械工业出版社,1998

21

西安工业大学北方信息工程学院

课程设计(论文)

题目:细丝直径测试仪

学别:业:级:生:光电信息系光电信息工程B100105B10010511

李媛学号:任课教师:2013年10月

基于CCD 测量细铜丝直径系统设计

摘要

近年来,随着新型光电器件的不断涌现、单片机数据处理能力的提高和生产全面质量管理的要求,非接触式智能化仪器将逐步取代传统上的机械测量仪器本文设计了一套基于线阵CCD 的非接触直径测量仪器,该装置可以对φ0.5mm ~φ30mm 的工件进行测量,测量精度为±5μm 。本文论述了CCD 光电尺寸测量装置的基本原理,分析了光学系统各部分的形式,采用柯拉照明和远心光路成像,以保证成像质量和测量精度。用微分法提取被测工的边缘信息,详细论述了信号处理电路中的各个模块的实现方法,并将微分法处理电路和单片机控制系统作为重点。同时还给出了CCD 测量直径系统的控制程序流程图及部分程序。通过实验得到测量结果,对几个重要参数进行了分析,最后就影响系统测量精度的几种主要误差进行了讨论,给出消除误差的方法,以便达到更高的测量精度。关键字:线阵CCD 直径测量远心光路微分法MSP430

ABSTRACT

In recent years, along with new optoelectronic devices flowing out continuously 、the capacity of MCU data processing improving, and the requirements of overall production quality management, non-contact Intelligent machines will replace the traditional mechanical instruments gradually. In this paper, I designed a set of portable non-contact measurement instruments based on linear array CCD, which can measure the workpiece fromφ0.5mmto φ30mm,with measurement precision±5μm. In this paper, I discussed the basic principle of CCD photoelectric measurement devices, analyzed the form of parts of optical system, adopt Kohler illumination and telecentric beam path design in order to ensure image quality and accuracy. Adopting differential theory extracted edge information of measured workpiece, and discussed the signal processing circuit in the realization of the various modules in detail, and made the differential processing circuitry and single-chip control system as emphases, at the same time I gave control program flow chart of CCD diameter measurement system and related parts procedures of it. Through experimental measurement results, I analyzed several important parameters, discussed several major errors which influences the accuracy of system in the end, gave the method of elimination of errors, in order to achieve higher measurement accuracy.

Key Words:Line ararray CCD Diameter measurement

Telecentric optical path Differential theory MSP430

1录绪论.................................................................................................................. 5

1、1

1、2

1、3

1、4前言.................................................................................................... 5基于CCD 测径仪的发展现状国外发展现状.................................... 5国内发展现状.................................................................................... 6论文的主要内容................................................................................ 7

利用衍射法测量细铜丝直径............................................................ 7

利用分光法测量细铜丝直径............................................................ 8

线阵CCD 测量直径系统测细铜丝直径............................................ 9

成像系统.......................................................................................... 12

设计方案的论证与选择采用.......................................................... 13

整体系统设计.................................................................................. 13

光学系统设计.................................................................................. 14

3、2、1

3、2、2

3、2、3光源.................................................................................... 14光源照明............................................................................ 14成像光学系统.................................................................... 142测量原理和方案论证.................................................... 错误!未定义书签。2、12、22、32、42、53光学系统设计................................................................................................ 133、13、2

4精度分析........................................................................................................ 15

4、1光学系统对测量精度的影响分析.................................................. 15

4、1、1、衍射.................................................................................... 15

4、1、2、环境光扰动........................................................................ 15

4、2

4、3

4、4

4、5

4、6信号处理电路对测量精度的影响分析.......................................... 16零点漂移对测量精度的影响.......................................................... 16被测工件的均匀性对测量精度的影响.......................................... 16误差分析.......................................................................................... 16仪器误差.......................................................................................... 16

设计总结.......................................................................................... 17

学习体会.......................................................................................... 175总结................................................................................................................ 175、15、2

参考文献.............................................................................................................. 17

1

1、1前言绪论

光电自动检测技术在工业自动化生产中有着极其广泛和重要的用途。然而,目前产品零件尺寸的检测大多数是人工测量的接触式和静止测量,所以检测速度低,生产效率低,劳动强度大,远远跟不上目前自动化生产的需要。尤其在全面质量管理过程中,更需要先进的、智能的检测手段。目前,国内外常采用激光扫描光电线径测量[1~5],但是这种方法受电机的温度及振动的影响,扫描恒速度的限制,会产生高温使其降低寿命。我们研制的基于线阵CCD 便携式非接触直径测量仪器正是适应当前社会自动化生产的急需而设计的,该测径仪是一种光、机、电一体化的产品。尤其适用于电缆、电线、玻璃管、轴类零件的外径测量,对保证产品质量,降低原材料消耗,降低生产成本,提高劳动生产率有着重大的经济效益和社会意义

对各种细丝直径的测量常常关系到工业产品的级别,如钟表中的游丝、光导纤维、化学纤维、各种细线、电阻丝、集成电路引线以及种类仪器、标尺的刻线等。传统的测量方法多数为接触法,其它的有电阻法、称重法。也有采用光学方法的,如光学显微镜法、干涉法、扫描法、投影放大法、比较法等。然而,大多检测方法检测速度低,生产效率低,劳动强度大,远远跟不上目前自动化生产的需要。尤其在全面质量管理过程中,更需要先进的、智能的检测手段。目前,国内外常采用激光扫描光电线径测量,但是但激光衍射细丝测量法比较适合于静态的高精度测量,当用于动态测量时会由于被测丝的晃动导致衍射条纹快速移动而失准,也难以快速得到测量结果,同时还具有结构复杂、格昂贵等缺点,不太适于现场快速测量细丝直径。基于CCD 技术的快速发展及后续处理算法的日益真实有效故CCD 在现代自动化生产中扮演者越来越重要的作用。为满足大工业化生产线阵CCD 测径仪便应运而生,该测径仪是一种光、机、电、算于一体的产品。尤其适用于电缆、电线、玻璃管、轴类零件的外径测量,对保证产品质量,降低原材料消耗,降低生产成本,提高劳动生产率有着重大的经济效益和社会意义。1、2基于CCD 测径仪的发展现状国外发展现状

社会的进步重要体现就是科技的进步,科技进步主要体现使用劳动工具的进步。从18世纪工业革命以来,科学技术以前所未有的速度在突飞猛进的发展,特别是近50年来,随着现代化生产和加工技术的发展,对于加工零件的检测速

度与精度有了更高的要求,向着高速度、高精度、非接触和在线检测方向发展。为此,工业发达国家对于检测仪器与设备速度与精度一直作为检测仪器的主要指标。CCD 测径仪特别适用于电缆、电线的在线自动检测,对保证产品的质量,降低原材料消耗,降低生产成本,提高劳动生产率有着十分重要的意义,所以各国政府都很重视对测径仪的研究。英国Beta AS3系列全新的激光测径仪:LD1040-S(单向直径测量仪) 、LD1040XY-S(双向直径测量仪) ,精度:0.1μm ,测量范围最广,单向测径仪最大可测直径达330.3mm ,双向测径仪最大可测直径值达100mm ,测量精度最高,最高测量精度可达0.1μm ,是目前同类产品中的最高的测量精度。日本生产的LS-7000系列高速、高精度CCD 测量仪器,如:LS-7030M (配备测量摄影机)测量范围:0.3mm ~30mm ,测量精度:±2μm ,重复性精度:±1.5μm 。LS-7010M (配备测量摄影机)测量范围:0.04mm ~6mm ,测量精度:±0.5μm 。

1、3国内发展现状

国内由于自身的工业加工水平有限、测量原理的不完善和结构搭理欠合理,所以,国内生产的测径仪测量精度没有国外的精确,河北省激光研究所光电检测控制室生产的JCJ-1激光测径仪,是专为玻璃管生产线上玻璃管外径的测量、控制、分选而设计的集激光、精密机械、计算机于一体的智能化精密仪器。通过激光光束高速(200次/秒)扫描被测玻璃管,计算机实时采样处理,实现玻璃管直径在线非接触检测、控制,测量范围:0.5mm~60mm,测量精度:±0.01mm。广州一思通电子仪器厂生产的ETD-05系列激光测径仪,测量范围:0.2mm~30mm,测量精度:±2μm,ETD-05系列激光测径仪是一种基于激光扫描测量原理而设计的高精度非接触式的外径测量设备,仪器采用二维测量模式,有效消除工件振动造成的测量误差,特别适合生产现场的实时测量,适用于通信电缆、光缆、同轴电缆、漆包线、PVC管、铜管、纤维线等圆形线材的在线检测,也可用于其它各种圆形工件的外径测量。南京亿佰泰科技有限公司生产的TLSM100激光扫描测微仪,测量范围:0.2mm~30mm,测量精度:±3μm,是一种高精度、非接触的尺寸测量仪器。它通过激光束的扫描获得被测目标的尺寸,广泛用于测量热的、软的、易碎的以及其它传统方法不易测量的物体,而且很适合生产中的在线测量或者线材、棒材、管材、机械和电子元件以及其它生产过程的监控。TLSM100的自动方式适用于连续的测量;手动方式适合单次测量。它可以设置上下偏差、峰值限制,当超限后做相应的报警;还可以计算最大值、最小值、平均值。例如:可以测量旋转圆柱体的最大值、最小值,辊子的偏差。我们研制的基于线阵CCD 测径仪测量范围:0.5mm~30mm,测量精度:±5μm,适用于对被测工件进行静

态测量,也适用于生产现场的实时测量。

1、4论文的主要内容

(1)深入了解CCD,尤其是在线阵CCD 结构与工作原理的基础上,选择合理的线阵CCD,设计出合理的测量直径系统。对整个光电测量装置进行系统分析,包括CCD 所构成的测量直径系统的基本原理和输出信号处理电路。

(2)在进行光电测量装置设计时,对光学系统进行了详细分析,并用ZEMAX 软件设计柯拉照明系统中的集光镜、聚光镜和成像物镜。

(3)提出线阵CCD 测量方案:基于单片机的硬件测量法。单片机的硬件测量法是从CCD 出来的电信号经前置放大,滤波电路进行二值化处理,然后送入单片机,在经单片机处理后送入LED 显示。

(4)设计实验分别对几组直径应用上述方法进行测量,对测量结果进行比较、分析,同时对产生测量误差的主要原因给予分析

2、1利用衍射法测量细铜丝直径

我们选择了最简单的一种模型,它是常规的夫琅和费衍射。即把金属丝当成一个平面的狭缝, 其工作情况如图2-2所示。光源发出的平行光束垂直照射在单缝(金属丝) 上. 根据惠更斯-菲涅耳原理, 单缝上每一点都可以看成是向各个方向发射球面子波的新波源, 子波在接收屏上叠加形成一组平行于单缝的明暗相间的条纹. 和单缝平面垂直的衍射光束会聚于屏上x=0处, 是中央亮条纹的中心, 其光强为I0; 与光轴成θ角的衍射光束会聚于x=x(θ) 处, θ为衍射角, 由惠更斯-菲涅耳原理可

得光强分布

图2-1夫琅和费单缝衍射

sin 2u πD sin θI =I o , u =λ(2-1)

为式中D 为缝宽,λ为入射光波长.当θ=0时,I=I0,是中央主极大.当sinθ=kλ/D时,其中k=±1,±2,…,I=0,是暗条纹.由于θ很小,故sinθ≈θ,所以近似认为暗条纹出现在θ=kλ/D处.中央亮条纹的角宽度Δθ=2λ/D,其他任意两条相

邻暗条纹之间夹角Δθ=λ/D,即暗条纹以x =0处为中心.当使用激光器作光源时,由于激光的准直性,可将透镜L1去掉.如果接收屏远离金属丝(z>>D),则透镜L2也可省略.由于tgθ=x/z,且tgθ≈sinθ,则各级暗条纹衍射角应为sin θ=k λD =x

z (2-2)

由此可以求得金属丝直径为

D =kz λ

x k (2-3)

式中k 是暗条纹级数;z 为金属丝与测量平面间的距离;XK 为第k 级暗条纹距中央主极大的距离。

2、2利用分光法测量细铜丝直径

发光管D1发出的红外光经分光镜分成两路:测量光路和参考光路。测量光和参考光分别照射到两只相同型号的光电接收管T1、T2上。D1为中心频率880nm 的进口红外发光管; T1、T2为高一致性、线性度的进口光电三极管; 截止波长为850nm 的低通滤波片可有效地消除可见光干扰

图2-2分光法光路图

T2的输出电压分别为V 1和

V 1、V 2的差动电压值在测量光和参考光的照射下,T1和V 2, 在测量光路中没有被测细丝时, V 1=V 2, 此时

细丝直径d , 高度为检测窗口高度V i =0. 当测量光路有被测细丝时, 细丝在T1的检测窗口上产生一个宽度为h 的投射阴影, 导致V 1发生变化, 变化量ΔV 1与投射阴影面积d ・h 成正比; 由于在电路中采用了负反馈自动光强

调整技术, 使发光管发射的光强稳定不变, 此时V 2保持恒定值不变; 以V 2作基准, V 1、V 2的差动电压值V i =ΔV 1, 将V i 放大即可得到与被测细丝直径成线性关系的电压信号,

达到测量细丝直径的目的。

图2-3分光法原理图

2、3线阵CCD

测量直径系统测细铜丝直径

图2-4线阵CCD 测量直径系统结构图

被测工件被均匀照明后,经光学成像系统按一定倍率成像于线阵CCD 传感器上,基于线阵CCD 测量直径系统原理图如图2-5所示:

2-5线阵CCD 测量直径系统原理图

则在CCD 传感器光敏面上形成了被测工件的影像,这个影像反映了被测工件的直径尺寸,两者之间的关系由高斯公式表示为:

⎧l ' ⎪β=⎪d ' ⎪d =⎨β⎪⎪1-1=1⎪⎩(2-4)

其中:l-----物距

率l ′----像距f ′---像方焦距β----光学系统的放大d----被测工件的直径大小d ′---被测工件直径在CCD 上影像大小知道物距、像距并测出工件影像d ′的大小,即可求出被测工件的尺寸。

CCD 器件把光敏元上工件影像的光学信息转换成与光强成正比的电荷量。存储于MOS 电容中,用一定频率的时钟脉冲对CCD 进行驱动,则电荷定向转移到输出端。视频信号中每一个离散电压信号的大小对应着该光敏元所接收光强的强弱,而信号输出的时序则对应CCD 光敏元位置的顺序。最终,被测工件的影像大小反映在CCD 输出信号中变为输出信号电压的高低,即在CCD 中间被影像遮挡部分的光敏元输出电压低,两侧未被遮挡的光敏元输出电压高。CCD 的输出信号如图2-4所示

图2-6CCD 输出信号

最终由CCD 实现按空间域分布的光学图像信息向按时间域分布的电压信号转化,该输出电压信号经过信号处理后,可得到表示d ′大小的脉冲信号,脉冲信号送入单片机中,测出脉冲宽度,进而可求出被测工件的大小。即用CCD 复位脉冲(对应CCD 的光敏元)可求出尺寸的大小。若:δ为脉冲当量(CCD 脉冲),N 为CCD 器件像数,N1,N2为光照部分的光敏信号输出脉冲数,β为光学系统的放大倍数,则被测工件直径[7~9][12]为:D =[N -(n 1+n 2)]⨯δN ' ⨯δβ

=β(2-5)

本设计中δ=7μm ;N=5000;β=1,所以实际上被测工件直径尺寸为:

[5000-(n 1+n 2)]⨯7⨯10-3N ' ⨯7⨯10-3D ==11(2-6)

由于被测工件的边缘是通光和挡光的交界点,理论上该处的光强变化率最大,该点就是滤波后的视频信号电压函数v=v(t)在过渡区内的拐点,由高等数学知识知道,在拐点处,电压函数的一次微分为最大值,二次微分为零。基于以上原理,在测量系统中对CCD 输出信号采用微分法处理,便于寻找被测工件的边缘[10~11]。微分法的波形图如图2-7所示:

2-7微分法的波形

2、4成像系统

成像系统采用物方远心光路[10][13~20]。在光电检测中,常常在生产线上对工件进行动态测量或在实验室中进行静态测量,如测量钢丝直径、玻璃管直径或轴类零件等,为了提高测量精度,常采用远心光路和柯拉照明一起配合使用。对物体(工件)大小的测量,一般是将物体按一定倍率要求,经光学系统成像在CCD 的接收面上,然后对CCD

输出信号进行测量。

图2.8成像原理图

按照此种方法进行物体线性尺寸测量时,光电器件与物镜之间的距离应保持不变,其测量精度在很大程度上取决于像平面与光电器件接收面的重合程度。由于在测量过程中,工件常常会沿光轴方向有所移动,使像平面与光电接收面不可能真正重合,因而产生了测量误差如图2.8所示。图2.8中B1B2为被测物体;B1′B2′表示被测物体像的大小;M1M2为光电器件接收面,由于B1′B2′与M1M2二者不重合,使像点B1′B2′在M1M2上形成弥散班,在CCD 器件接收面上,实际测量像的大小为M1M2,显然它与实际的像长B1′B2′是不同的。这就使测量产生了很大的测量误差。为了消除这种误差,可以通过控制主光线的方向来达到,我们在设计成像物镜时选择了远心光路,如图2.9

所示:

图2.9物方远心光路

2、5设计方案的论证与选择采用

光学衍射法测量细铜丝直径在理论上已经很成熟,但实际应用中存在一定困难,特别是在测量精度提高时,其中的关键困难在于:当光经衍射后产生的衍射图样微弱,信号的信噪比比较低,还由于衍射图样的锐度不大,条纹位置不明显,给测量带来很大困难。特别是在实时动态测量过程中,造成测量结果不稳定,重复性差。而且本次测量的细丝直径为1mm ,在这个直径下不能形成明显的衍射条纹,即衍射法在原理上存在不足。

分光法在测量实质上是干涉法测量但也有不足:1、如果细丝有垂直于测量光方向的晃动, 且晃动的幅度使投射阴影超出检测窗口之外, 将会改变阴影面积进而产生较大的测量误差;2、光照在细丝上会产生微弱的衍射效应, 衍射会导致线性度变差;3、环境光扰动会降低信噪比, 影响测量精度;4、光电三极管对温度有一定的敏感性, 会随温度的变化而产生灵敏度的变化;5、分光法也不适合于与计算机的连接以及后续图像采集与处理保存。以上不足使得反光法对现代化自动化生产有一定的局限,但分光法在原理上不存在任何问题。

与同类测量系统比较,CCD 细丝直径测量系统具有测量速度快,测量精度高,抗干扰能力强等优良特点,是一种非接触式的测量系统,属无损伤测量,不影响加工系统正常运行,非常适合于生产线上尺寸的测量。该设计方案集成化程度高,可与计算机相联,可进行测量数据的集中采集和分析,以便进行质量分析和统计,并在生产过程中出现质量问题时进行报警提示,便于控制和自动化生产。

综合上述分析及我们小组的讨论研究,我们决定采用CCD 细丝直径测试仪的设计方案。

3

3、1整体系统设计光学系统设计

测量完整框图如图3-1所示。He-Ne 激光器发出的激光经反射镜M1、扩束系统M2后形成均匀的测量光,测量光经空间滤波器消除杂散光后入射被测量细丝,经光学系统在探测(CCD)上形成衍射条纹。CCD 将衍射图样转换为电信号经信号调整电路处理后进入计算机,处理采集到的信号,求得衍射图样中暗点的分布尺寸。为保证测量精度,消除细丝抖动带来的误差,CCD 的驱动电路要保证CCD 的积分时间足够短。

图3-1系统原理框图

3、2光学系统设计

3、2、1光源

测试中采用半导体激光器。半导体激光器又被称为二极管激光器(LED),是体积最小的激光器件,它结构简单坚固,便于直接调制。经过多年的发展,半导体激光器件的可靠性寿命从几分钟增加到百万小时,波长覆盖从中红外到近紫外,输出功率从豪瓦直到百瓦水平。半导体激光器工作物质是半导体材料,常用材料是砷化嫁,其结构原理与发光二级管类似。半导体激光器作为检测光源通常要求光源输出光强的稳定性好,引起激光光弧变化的因素有激光器电源稳定性的好坏、激光器的结构微小几何量变化以及它随工作时间的变化而产生的热变形与应力等。所以,激光器需要使用稳压电源。

3、2、2光源照明

由于半导体激光器有源层横截面的对称和很小的线度,半导体的远场光斑即不对称又具有很大的光束发散角,且发散角不同,垂直于结平面方向的发散角很大,一般高达50°,平行于结平面方向的发散角也有10°。所以应用半导体激光器的光学系统需考虑激光束的准直、像差的校正和椭圆光束的整形,因而需设计准直光学系统和整形光学系统。

3、2、3成像光学系统

由于生产线上细丝的摆动造成物距改变,从而使像平面与光电接受面不可能真正重合,带来测量误差。为消除其对测量的影响,提高测量精度,成像系统中我们采用物方远心光路,如图3-2所示

图3-2远心光路图

物方远心光路的基本原则为:在物镜的像方焦面处设置孔径光阑,即为物镜的出瞳,其入瞳位于无穷远处。物体上各点发出的光束经物镜后,其主光线必通过光阑中心所在的像方焦点F',而其物方主光线均平行于光轴。如果物体B1B2正确的位于与光电器件接受面M1M2共轭的位置A1,则在光电器件上像的长为M1M2。如果物体B1B2沿光轴有所移动,位置改到A2处,其像面B1'B2' 将与光电器件接受面不重合,而在光敏面上得到的是B1和B2弥散斑。但在物方空间,由于物体上同一点发出的主光线方向不变,其像方主光线必通过像方焦点F',因此光电器件接受面上的弥散斑中心仍通过M1M2点,从而提高了测量精度。

4精度分析

4、1光学系统对测量精度的影响分析

4、1、1、衍射

光照在细丝上会产生衍射效应,衍射会导致线性度变差。试验证明:在20um 以上,线性度是比较好的;在20um 以下线性度较差,但Vi 与d 的正相关关系没有改变,此时应采用值运算拟合法来提高精度。

4、1、2、环境光扰动

环境光扰动会降低信噪比,影响测量精度。在使用了滤波片后已滤除了大部分干扰光,再加上遮光罩可使环境光扰动忽略不计。

4、2信号处理电路对测量精度的影响分析

由于外界环境及电路自身元器件的不稳定性,会使得测量结果偏离理想状况。

4、3零点漂移对测量精度的影响

1、什么是零点漂移现象:ΔuI =0,ΔuO ≠0的现象。

2. 产生原因:温度变化,直流电源波动,器件老化。其中晶体管的特性对温度敏感是主要原因,故也称零漂为温漂。

3. 克服温漂的方法:引入直流负反馈,温度补偿。典型电路:差分放大电路4、4被测工件的均匀性对测量精度的影响

在生产过程中,轴类零件,电缆或电线的外径有时不很均匀。被测工件经过光照在CCD 成像,线径不等时则被照部分CCD 输出脉冲数与均匀被测工件被照部分的CCD 输出脉冲数不等,反应到测量结果上就会产生测量误差,在设计中,我们采用对被测工件的多次测量,然后求取平均值的方法来消除这种误差。粗大误差也影响测量精度,但它是有外界条件的突然变化引起的,当外界条件改变时引起CCD 输出信号的不稳定,只要保证外界条件持续稳定,则粗大误差就很少发生。

4、5误差分析

在实验过程中,我们分别对直径φ=1.0mm的标准件进行了三组测量,每一组采取多次重复测量,取平均值,并进行相应的精度计算。

4、6仪器误差

根据误差合成理论知仪器总误差为:)))∆系统∆+(∆+(∆)+(∆H es mt ∑222mm 2

5

5、1设计总结总结

本课题的研究是以线阵CCD--光电传感器TCD1501D 及光学镜头为基础构建的光学测量系统,对CCD 的输出信号采用微分法提取被测工件的边缘信息,由单片机对数据进行处理完成测量工作。本文从光学系统设计入手展开研究:包括测量直径系统的构建、线阵CCD 测量器件的选择、光学镜头的设计及实验研究,同时对系统组成的硬件电路、程序设计做了相应的介绍。综上所述,本课题的研究主要做了以下方面的工作:设计了基于线阵CCD 的直径测量系统。包括线阵CCD 的选型,光源的选取,光学镜头的设计,介绍线阵CCD 光学测量原理。在进行光电测量装置设计时,对光学系统进行了详细分析,并用ZEMAX 软件设计了柯拉照明系统中的集光镜、聚光镜和成像物镜。本论文从实验上实现了使用CCD 技术进行非接触测量,特别是对输出信号不采用传统意义上的阈值处理法,而采用微分法对工件的边缘信号进行提取,用MSP430F149单片机进行数据处理并编制相应的程序。用CCD 测径系统对几组直径做实验研究,分析了测量系统的误差。由测量结果可知,测量精度在±5μm 之内。如果从以下几个方面进行改进,可以得到更高的测量精度。

光学系统的设计、光学系统的准确调节、镜头装调和校验。测量时,若CCD 感光面与像面不重合,CCD 将接收到模糊的图像信息,造成测量误差,以后可以采用增加瞄准部分来解决。CCD 传感器的像元尺寸的几何位置精度高,可靠性高,寿命长,适合较恶劣的自然环境,CCD 技术被应用在几乎所有的成像相关的领域,随着科学技术的发展以及CCD 技术的研究和应用,CCD 技术将得到普及和推广。鉴于我小组成员的知识结构及经验有限,论文基于线阵CCD 便携式直径测量系统设计还存在许多不完善的地方,有待于在今后的研究中进一步完善。也希望学校在这方面对学生多给予实践上的帮助,脱离了实践的设计往往是个空中楼阁,想要真正把这些问题做到还得大家的共同努力。

5、2学习体会经过这次的课程设计,我个人得到了不少的收获,一方面加深了我对课本理论的认识,另一方面也提高了实验操作能力。现在我总结了以下的体会和经验。

这次的课程设计跟我们以前做的课程设计有所不同,因为我觉得这次我是真真正正的自己亲自去完成。所以是我觉得这次课程设计最宝贵,最深刻的。就是

课程设计的过程全是我们自己动手来完成的,这样,我们就必须要弄懂课程设计的要求。在这里我深深体会到哲学上理论对实践的指导作用:弄懂课程设计要求,而且体会到了课程设计的操作能力是靠自己亲自动手,亲自开动脑筋,亲自去请教别人才能得到提高的。

我们做课程设计绝对不能人云亦云,要有自己的看法,这样我们就要有充分的准备,若是做了也不知道是个什么课程设计,那么做了也是白做。课程设计总是与课本知识相关的,比如:此次的课程设计就必须回顾课本的知识,知道课程设计将要面对的难题、运用的什么物理量,写报告时怎么处理这些物理量。在课程设计过程中,我们应该尽量减少思路上的盲区以提高课程设计的效率,有的人一开始就赶着做,结果却越做越忙,主要就是这个原因。我也曾经犯过这样的错误。我们做课程设计不要一成不变和墨守成规,应该有改良创新的精神。实际上,在弄懂了课程设计原理的基础上,我们的时间是充分的,做课程设计应该是游刃有余的,如果说创新对于我们来说是件难事,那改良总是有可能的。比如说,在做课程设计时,我们可以通过不同思路、不同方法来解决。

在课程设计的过程中我们要培养自己的独立分析问题和解决问题的能力。培养这种能力的前题是你对此次课程设计的态度。如果你在课程设计这方面很随便,抱着等老师教你怎么做,拿同学的报告去抄,尽管你的成绩会很高,但对将来工作是不利的。

在这次的课程设计中,我对一些测试硬件、软件及其使用有了更深刻的认识。本人认为,在做这次的课程设计中,学习ZMAX 软件、光电仪器设计知识等知识,是一件很有趣的事情,因为ZMAX 软件是一个很好的软件,它能够对各种测试结果进行准确的分析实在是太神奇了,所以我觉得ZMAX 软件的起到非常重要的作用。

最后,通过这次的课程设计我不但对理论知识有了更加深的理解,对于实际的操作也有了质的飞跃。经过这次的课程设计,我们整体对各个方面都得到了不少的提高,希望以后学校和系里能够开设更多类似的课程设计,能够让我们得到更好的锻炼。

参考文献

1Harry prunk.The latest development in measuring equipment for online quality control at the cable extrusion[J].WireJournal International,2000,7:104~111.

2张国玉,安志勇,李成志等.双光束激光扫描尺寸测量系统[J].半导体光电,1998,5(16):320~323.

3邓景珊,张力,朱永茂等.核电站燃料2UO 芯块直径在线激光扫描测量[J].应用激光,2001,3(21):180~182.

4李慧鹏,王军,张军,唐文彦.一种新型非接触式线径测量系统[J].仪器仪表学报,2004,25(4):209~211.

5徐熙平,姜会林,张国玉著.光电尺寸检测技术及应用[M].吉林省科学技术出版社,2004,6~22.

5徐春梅.提高CCD 用于非接触式测量小精度的研究及其模拟实验.河北工业大学硕士学位论文,2000.1.

6康华光著.电子技术基础模拟部分[M](第四版).高等教育出版社,1987.8. 7佟首峰,阮锦,郝志航.CCD图像传感器降噪技术的研究[J].光学精密工程,2000,

8张林,李永新,胡学友.基于相关双采样的CCD 视频信号处理研究[J].宇航计测技术,2007

9黄美玲,张伯珩,边川平,李露瑶,达选福.相关双采样技术在航天相机中的应用研究[J].传感器技术,2005

10李艺琳,冯勇,安澄全.用相关双采样技术提高CCD 输出信号的信噪比

[J].电测与仪表,1999,第5期

11佐藤一郎著.集成运算放大器电路设计实用手册[M].学术期刊出版社,1989年第1版.

12费业泰.误差理论与数据处理[M].北京:机械工业出版社,199813郁道银,谈恒英主编.工程光学[M].机械工业出版社.

14吴福田,冯书文.CCD尺寸测量光学系统设计原理[J].应用光学,1994,15(5):20~22.

15王向军,王风华,周鑫玲.物像远心成像光路在高精度视学检测中的应用

[J].测试技术学报,1998,12(3):149~153.

16朴明波.对利用CCD 技术进行实时在线非接触式线径测量的研究.辽宁工程技术大学硕士论文,2003.12.

17孙学珠,付维乔,刘庆,王庆有.高精度CCD 尺寸自动检测系统的光学系统的设计[J].应用光学,1998,16(1):9~12.

18杨淋,周肇飞,张涛,晋崇就.线阵CCD 在高精度测量系统中照明选择[J].实用测试技术,2002,第5期,20~22.

19徐春梅.提高CCD 用于非接触式测量小精度的研究及其模拟实验.河北工业大学硕士学位论文,2000.1.

20康华光著.电子技术基础模拟部分[M](第四版).高等教育出版社,1987.8.

21张南洋生,张波,杨坤涛.一种变阈值二值化CCD 像元细分技术研究[J].半导体光电,2006,27(4):471~474.

22佟首峰,阮锦,郝志航.CCD图像传感器降噪技术的研究[J].光学精密工程,2000,8(2):140~145.

23张林,李永新,胡学友.基于相关双采样的CCD 视频信号处理研究[J].宇航计测技术,2007,27(4):33~37.

24Leonard Forbes,Harish Gopalakrishnan, and Weetit Wanalerlak. Analysis and simulation of noise in correlated double sampling imager circuits Proc of SPIE Vol 5844:238~247.

25黄美玲,张伯珩,边川平,李露瑶,达选福.相关双采样技术在航天相机中的应用研究[J].传感器技术,2005,24(8):31~33.

26李艺琳,冯勇,安澄全.用相关双采样技术提高CCD 输出信号的信噪比

[J].电测与仪表,1999,第5期,36(401):31~32.

27DALSA,Applications of high speed A/Din CCD imaging, DALSA 1996~1997DATABBOOK,1997.

28AD, analog device ,AD 1997~1998Databook,1997.

29许秀贞,李自田,薛利军.CCD噪声分析及处理技术[J].红外与激光工程,2004,33(4):140~145.

30佐藤一郎著.集成运算放大器电路设计实用手册[M].学术期刊出版社,1989年第1版.

31沈建华,杨艳琴,翟晓曙.MSP430系列16位超低功耗单片机原理与应用[M].清华大学出版社,2004年11月第1版.

32龙编著.MSP430单片机常用模块与综合系统实例精讲[M].电子工业出

版社,2007年7月第1版.

33光电自动检测原理及应用[M].长春光学精密机械学院,1981年.

34李永远,谢小平.CCD输出信号处理[J],应用光学,1997,(1):20~23.35杨博雄,胡新和,博辉清.CCD工作噪声分析与处理.光学与光电技术,2004;2(4):51~53.

36费业泰.误差理论与数据处理[M].北京:机械工业出版社,1998

21


相关内容

  • 细丝直径的数字图像测量算法
  • 第31卷第5期2008年10月 辽宁科技大学学报 Journal of University of Science and Technology Liaoning Vol. 31No. 5Oct. , 2008 细丝直径的数字图像测量算法 张疏影 (鞍山市第一中学, 辽宁鞍山 114051) 摘 要 ...

  • 狭缝缝宽和细丝直径的测量
  • 编号: 课程设II (论文)计说明书 题 目: 狭缝缝宽和细丝直径测 量 院 (系): 电子工程与自动化学院 专 业: 学生姓名: 学 号: 指导教师: 职 称: 30217 张 副教授 2016年 1 月20日 摘 要 本课题主要目的是狭缝缝宽和细丝直径的测量.微小物体的测量在生产和科研中有很重要 ...

  • 细丝直径的测量铁丝直径
  • 细丝直径的测量铁丝直径 [实验目的] (1)通过实验加深对等厚干涉原理及干涉概念的理解 (2)学习用等厚干涉测量铁丝直径的方法 (3)学会读书显微镜的正确使用 [仪器用具] 钠光灯 读数显微镜 劈尖装置 [实验原理] 当两片很平的玻璃叠合在一起,并在其一端垫入细丝时,两玻璃片之间就形成一空气薄层(空 ...

  • 劈尖干涉测量头发丝直径
  • 劈尖干涉测量头发丝直径 摘要:根据等厚干涉原理,利用劈尖干涉,成功测量除了头发丝的直径. 关键词:干涉 劈尖 细丝直径 1. 引言:根据薄膜干涉原理,用两个很平的玻璃板间产生一个很小的角度,就构成一个楔形空气薄膜,用已知波长的单色光入射产生的干涉条纹,可以测量头发丝的直径. 2. 设计方法及设计原则 ...

  • 小尺寸物体光学测量方法
  • 小尺寸物体光学测量方法 李闯闯 (华东师范大学,物理与材料学院,上海市,邮编:200000) 摘要:测量微小长度的方法很多,除了游标卡尺,螺旋测微器,读书显微镜等简单的长度测量方法外,利用激光强度高,干涉性好,方向性好的特点,设计出的光学测量方法也有很多,本文将先对实验中的线阵CCD 测量物体尺寸进 ...

  • 实验 测定单缝衍射的光强分布
  • 实验 测定单缝衍射的光强分布 实验目的 1.观察单缝衍射现象,加深对衍射理论的理解. 2.会用光电元件测量单缝衍射的相对光强分布,掌握其分布规律. 3.学会用衍射法测量微小量. 实验仪器 激光器,单缝,硅光电池,读数显微镜,光点检流计和米尺. 实验原理 1.单缝衍射的光强分布及单缝宽度的测量 当光在 ...

  • 皮肤的结构分析
  • 皮肤的结构分析 一. 皮肤的解剖 皮肤(skin)由表皮.真皮和皮下组织组成,表皮与真皮之间由基底膜带连接.除了本身结构外,尚有丰富的血管.淋巴管.神经.肌肉和各种皮肤附属器,包括毛发.毛囊.皮脂腺.小汗腺.顶泌汗腺.甲.皮肤覆盖整个体表,在口.鼻.尿道口.阴道口.肛门等处与体内管腔粘膜相移行.皮肤 ...

  • 等厚干涉实验报告
  • 等厚干涉实验报告 (2011-04-27 12:36:57) 转载 标签: 分类: 大一作业 杂谈 [实验目的] 1.观察光的等厚干涉现象,熟悉光的等厚干涉的特点. 2.用牛顿环测定平凸透镜的曲率半径. 3.用劈尖干涉法测定细丝直径或微小厚度. [实验仪器] 牛顿环仪,移测显微镜.钠灯.劈尖等. [ ...

  • 光纤施工规范
  • 站监控布线系统方案 光 缆 敷 设 方 案 北京安捷讯通有限公司 2005年10月 XX 目 录 第一章 布线系统概况„„„„„„„„„„„„„„„„„„„„„3 第二章 综合布线系统的定义.特点及其范围„„„„„„„„„4 第三章 光纤见解„„„„„„„„„„„„„„„„„„„„„„„5 第四章 ...