DB32 2037-2012 低温绝热气瓶定期检验要求

ICS 23.020.30 J 74

备案号:33698-2012

江苏省地方标准

DB32/ 2037—2012

低温绝热气瓶定期检验要求

Requirements of inspection for cryogenic insulation cylinder

2012 - 03 - 31发布 2012 - 05-31实施

目 次

1 范围..............................................................................1 2 规范性引用文件....................................................................1 3 基本要求..........................................................................3 3.1 3.2 3.3 3.4

检验机构和检验人员............................................................检验周期......................................................................检验项目......................................................................检验安全......................................................................

3 3 3 3

4 检验程序..........................................................................4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8

检验准备......................................................................内外部检查....................................................................真空度检测....................................................................安全附件检查与校验............................................................管路及阀门检查................................................................附件组装与脱脂................................................................气密性试验....................................................................静态蒸发率检测................................................................

4 4 4 5 5 5 6 6

5 检验结果的处理....................................................................6 5.1 5.2 5.3 5.4

结论判定......................................................................检验报告......................................................................不合格气瓶处理................................................................标志标贴......................................................................

6 6 6 6

6 检验报告的样式....................................................................7 附录A(规范性附录) 低温绝热气瓶外壳凹陷尺寸的测量方法..............................8 附录B(资料性附录) 低温绝热气瓶定期检验报告.......................................10

前 言

本标准第3章、第4章、第5章为强制性条文。

本标准按GB/T1.1-2009《标准化工作导则 第1部分:标准的结构和编写》的规定编制。 本标准由江苏省特种设备安全监督检验研究院常州分院提出。 本标准起草单位:江苏省低温绝热设备产品质量监督检验中心、江苏省特种设备安全监督检验研究院常州分院、查特深冷工程系统(常州)有限公司、张家港中集圣达因低温装备有限公司、常州博朗低温设备有限公司。

本标准起草人:李秀中、毛小虎、宁晔、赵耀明、顾志军、王渤、徐惠新、蔡浩、魏蔚、徐国强、朱燕梅。

低温绝热气瓶定期检验要求

1 范围

本标准规定了在用低温绝热气瓶定期检验的基本要求、检验程序、检验结果的处理和检验报告的样式。

本标准适用于盛装介质为液氧、液氮、液氩、二氧化碳、氧化亚氮、液化天然气(LNG)等低温液体,设计温度不低于-196℃,在正常环境温度即(-40~60)℃下使用,公称容积大于等于10L,公称工作压力为(0.2~3.5)MPa,可重复充装的焊接绝热气瓶和车用液化天然气绝热气瓶的定期检验。 2 规范性引用文件

下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅所注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。

GB/T 12137 气瓶气密性试验方法

GB/T 18443.2 真空绝热深冷设备性能试验方法 第2部分:真空度测量

GB/T 18443.5 真空绝热深冷设备性能试验方法 第5部分:静态蒸发率测量 JB/T 4730.5 承压设备无损检测 第5部分 渗透检测 JB/T 6896 空气分离设备表面清洁度 3 基本要求

3.1 检验机构和检验人员

3.1.1 进行低温绝热气瓶(以下简称:低温气瓶)定期检验的检验机构,须经国家特种设备安全监察部门核准,并具备按本标准开展检验的能力。

3.1.2 低温气瓶的检验人员须持有国家特种设备安全监察部门颁发的,具有低温气瓶检验资质的检验资格证书。 3.2 检验周期

低温气瓶的定期检验周期应符合国家气瓶安全技术规范的要求。当低温气瓶在使用过程中受到严重损伤,或对其绝热性能或安全性能有怀疑时,应提前进行检验。 3.3 检验项目

低温气瓶的定期检验项目包括内外部检查、真空度检测、安全附件检查和校验、管路与阀门检查、附件组装与脱脂、气密性试验、静态蒸发率检测。 3.4 检验安全

3.4.1 全部检验工作应确保低温气瓶不受损伤、不被油脂污染。

3.4.2 检验前,低温气瓶的余液(气)应完全排空,且瓶内温度应与正常环境温度一致。

3.4.3 检验前,盛装液氧、液化天然气的低温气瓶须使用氮气置换。 4 检验程序 4.1 检验准备

4.1.1 审核低温气瓶的出厂文件、前次定期检验报告、安全附件校验报告、修理情况等资料。

4.1.2 了解低温气瓶的运行情况、使用频率、有无异常现象发生、静态蒸发率变化情况、外壳有无结露和结霜等现象。

4.1.3 检查低温气瓶的制造标志和检验标志是否符合要求,检查情况应予登记。

4.1.4 检验前,应卸下安全阀、压力表、爆破片、液位计和调压阀等可拆卸的附件,并将气瓶表面的污垢、沾染物等有碍表面检查的杂物清除干净。

4.1.5 如果检查中发现有非法制造或非法进口的低温气瓶、制造标志不符合要求的低温气瓶、制造标志模糊不清的低温气瓶、非法改造的低温气瓶、实际充装介质与允许充装介质不符的低温气瓶以及有关规定不准再使用的低温气瓶,检查后不予检验,按报废处理。 4.2 内外部检查

4.2.1 采用目测或5~10倍放大镜对低温气瓶外部进行以下检查:

a) 检查低温气瓶外壳的对接焊缝、阀座与瓶体的角焊缝表面有无裂纹、咬边等焊缝缺陷。如发现

有裂纹,应对裂纹两侧各100mm范围内按JB/T 4730.5进行渗透检测;对发现有咬边、弧坑及其他有怀疑部位应按JB/T 4730.5进行渗透检测。

b) 检查低温气瓶外壳表面是否存在变形、凹陷、凹坑、机械损伤。

c) 检查螺纹是否开裂、磨损、变形或损伤。当螺纹存在磨损或其它损伤时,可用与原螺纹一致的

丝锥修复,修复后用量规检验。

d) 检查低温气瓶护罩、底部支座焊缝有无开裂、变形、损伤、脱落等现象。

4.2.2 用内窥镜检查低温气瓶内胆母材和焊缝的表面情况,应无裂纹、变形、机械损伤、杂物等。应对内胆的角焊缝和可疑部位照相,并对照片进行分析,照片应作为检验记录保存。 4.2.3 当检查发现下列情况之一时,该低温气瓶为不合格:

a) 低温气瓶焊缝有裂纹时;

b) 外壳凹陷深度大于或等于12mm,并且凹陷长度大于或等于外壳周长的13%时(外壳凹陷尺寸的

测量方法见附录A);

c) 螺纹有开裂或其他严重损伤时;

d) 护罩、底部支座因开裂、变形、腐蚀或其他机械损伤而失去作用的。 4.3 真空度检测

4.3.1 当存在下列情况之一时,应按GB/T 18443.2进行夹层常温真空度检测:

a) 距上次夹层真空度测试已有6年及以上的; b) 上次检验后瓶体经过修理的;

c) 使用中瓶体部位发生结露、结霜现象的; d) 对夹层真空度和绝热性能有疑问的。 夹层常温真空度小于或等于5Pa为合格。

4.3.2 夹层真空度检测在静态蒸发率检测前进行,当检测不合格时,应查明原因。对于因夹层材料放气或吸附剂失效导致不合格的,应投放吸附剂并且进行抽真空处理;对于因夹层密封损坏导致不合格的,按不合格气瓶处理。 4.4 安全附件检查与校验 4.4.1 基本要求

低温气瓶安全附件应完好、齐全、选型正确,并且在校准或校验有效期内。 4.4.2 安全阀

4.4.2.1 目测检查安全阀外观情况。安全阀外观应良好、无泄漏和堵塞现象、在校验有效期内且铅封完好。当不满足上述要求时,应予修校或更换。

4.4.2.2 安全阀每年至少校验一次,整定压力应符合气瓶的设计要求。 4.4.3 压力表

4.4.3.1 目测检查压力表外观情况。压力表的外壳应无严重腐蚀或损坏、表盘玻璃破裂、刻度不清、指针扭曲断裂、卸压后指针不回零位、铅封损坏等现象。有上述情况之一时,应予更换。

4.4.3.2 压力表每6个月至少检定一次,其精度不低于2.5级,量程为公称工作压力的1.5~3.0倍。 4.4.4 爆破片

目测检查爆破片外观情况。爆破片表面应无划痕,安装方式、方向、位置正确,爆破压力和爆破温度应符合设计要求,且在规定的使用期限内(制造单位未规定使用期限时,使用期限不超过3年)。当不满足上述要求时,应予更换。 4.4.5 液位计

目测检查液位计外观情况。液位计的外壳和保护罩应完好,液位计指示应清晰,数字式液位计显示应清晰、完整。如出现指示不清、假液位、表盘玻璃破裂等现象,应予修理或更换。 4.5 管路及阀门检查

4.5.1 采用目测或5~10倍放大镜检查,管路,接管和焊缝表面等处应无裂纹、压扁、堵塞等现象。检验不合格时,应按不合格气瓶处理。

4.5.2 阀门应启闭自如,不得有泄漏,采用目测或5~10倍放大镜检查,阀体和螺纹应无裂纹、变形或其它严重损伤。不符合要求时,应更换损坏的部件或按不合格气瓶处理。

4.5.3 将调压器解体清洗、更换阀头密封垫,目测检查外观情况。调整螺杆和螺母的螺纹应完好,鼓膜片及阀头应完好,弹簧无异常变形、裂纹、疲软等缺陷。不符合要求时,应修复或更换。调压器组装后应进行设定点调整,设定方法和设定压力应符合制造单位气瓶维护说明书的要求。 4.6 附件组装与脱脂

4.6.1 所有从瓶体上拆卸的附件经检验合格后,应按气瓶维护说明书的要求与瓶体组装。修理或更换的安全附件、阀门部件等应选型正确,所用的密封件应与气瓶盛装的介质相适应。组装过程中严禁金属屑等杂物掉入气瓶内胆。

4.6.2 对盛装液氧的气瓶,应按JB/T 6896的脱脂清洗要求对气瓶外壳、安全附件、管路、阀门及各拆装接口进行脱脂、去油处理。处理后采用白色、清洁、干燥的滤纸擦抹脱脂表面,纸上应无油脂和污物,确认合格后方可组装。 4.7 气密性试验

4.7.1 低温气瓶经附件组装与检查合格后,按GB/T 12137进行气密性试验,并符合下列要求:

a) 试验压力为气瓶的公称工作压力; b) 试验介质宜采用干燥、洁净的氮气; c) 试验方法采用涂液法。

4.7.2 当因附件组装不当而产生泄漏现象时,应重新组装后再进行试验。 4.8 静态蒸发率检测

4.8.1 低温气瓶气密性试验合格后,应按GB/T 18443.5进行静态蒸发率检测。静态蒸发率应小于或等于1.5倍的气瓶产品出厂标准规定的合格指标,并且焊接绝热气瓶还应同时符合表1的规定,车用液化天然气绝热气瓶还应同时符合表2的规定。

4.8.2 静态蒸发率检测过程中,如果低温气瓶瓶体上发生结霜现象时,应按不合格气瓶处理。

表1 焊接绝热气瓶静态蒸发率合格指标

公称容积L 静态蒸发率

10 8.2

25 6.3

50 4.5

100 4.2

150 3.8

175 3.2

200 3.0

300 2.9

450 2.7

≤%/d

表2 车用液化天然气绝热气瓶静态蒸发率合格指标

公称容积L 静态蒸发率≤%/d

50 5.4

100 5.1

150 5.1

200 4.8

250 4.8

300 4.8

350 4.5

400 4.5

450 4.2

500 4.2

4.8.3 检测完成后,瓶内应保留部分氮气,瓶内压力应为(0.05~0.1)MPa。对于盛装液化天然气的气瓶,应进行瓶内气体分析,取样时应在出气口抽取,瓶内氧气含量应小于或等于3%。 5 检验结果的处理 5.1 结论判定

当4.2~4.8的各检验项目全部合格,检验结论为合格。 5.2 检验报告

检验完成后应出具检验报告,气瓶产权单位(或气瓶使用单位)和检验机构各保存一份。 5.3 不合格气瓶处理

检验不合格的气瓶应修理或报废。当气瓶送修时,由检验机构直接将气瓶交与有资质的修理单位。当气瓶报废时,检验机构应按国家气瓶安全技术规范的要求,将气瓶进行报废处理后交气瓶产权单位。 5.4 标志标贴

检验合格的低温气瓶应按国家气瓶安全技术规范的规定,装检验标志环,并在标志环上打检验钢印。当气瓶的警示标志、标贴存在缺失、损坏、脱落现象时,应予修缮。 6 检验报告的样式

见附录B。

附 录 A

(规范性附录)

低温绝热气瓶外壳凹陷尺寸的测量方法

A.1 凹陷深度的测量方法

量具为游标卡尺、直尺。直尺应沿气瓶轴向放置,直尺长度应大于凹陷轴向长度的三倍,如图A.1

所示。

1——游标卡尺

2——钢直尺

3——气瓶外壳

4——凹陷

5——凹陷深度

图A.1

A.2 凹陷长度的测量方法

量具为游标卡尺。游标卡尺沿气瓶轴向放置,测量凹陷沿气瓶轴向的最大长度,如图A.2.a)所示;游标卡尺沿气瓶周向放置,测量凹陷沿气瓶外壳周向的最大长度,如图A.2.b)所示。取两者的最大值作为凹陷的长度。

a)

b)

1——游标卡尺

2——气瓶外壳

3——凹陷

4——凹陷轴向最大长度

5——凹陷周向最大长度

图A.2

附 录 B

(资料性附录)

低温绝热气瓶定期检验报告式样

报告编号:

低温绝热气瓶定期检验报告

送检单位:

气瓶型号:

安全条码号:

出厂编号:

检验日期:

(检验机构名称)

8

注 意 事 项

1、本报告书为对在用低温绝热气瓶进行定期检验的结论报告。

2、报告书应当由计算机打印输出,或用钢笔、签字笔填写,涂改无效。

3、本报告书无检验、审核、签发人员签字和检验机构的核准证号、检验专用章或者公章无效。 4、本报告书正本由气瓶产权单位(或气瓶使用单位)保存,副本由检验机构保存。

5、受检单位对本报告结论如有异议,请在收到报告书之日起15日内,向检验机构提出书面意见。

单位地址: 联系电话: 邮政编码:

9

www.bzfxw.com

报告编号:

低温绝热气瓶定期检验结论报告

送检单位 产权单位

出厂编号

(或使用单位)

制造单位

制造日期

气瓶型号

安全条码号 充装介质

公称工作压力公称容积最大充装量气瓶标记 检验依据:

资料审查 上次检验日期

检验发现的问题位置、程度、性质及处理意见(必要时附图或附页):

检验结论

下次检验日期

检验: 日期:

(检验机构名称)

机构核准证号:

审核: 日期:

(检验机构章) 日期:

签发: 日期:

共 页 第 页

10

报告编号:

低温绝热气瓶定期检验报告附页

检查项目

外壳的对接焊缝、角焊缝裂纹、泄漏

检查结果

备注及问题说明

内外部检查

外壳的变形、凹陷、凹坑、机械损伤 螺纹的开裂、磨损、变形或损伤

护罩、底部支座的开裂、变形、损伤、脱落 内胆母材表面的裂纹、变形、杂物 内胆焊缝的表面的裂纹、损伤等外观缺陷 安全阀

安全附件、管路及阀门检查 附件组装与脱脂

压力表 爆破片 液位计

管路接管角焊缝的裂纹 管路接管的损伤、堵塞 阀体和螺纹的裂纹

阀体和螺纹的变形、机械损伤 螺纹的磨损、机械损伤 阀门的启闭、泄漏 调压阀性能测试 修理或更换部件的选型 脱脂、去油处理

渗透检测 气密性试验 真空度 静态蒸发率

注1:没有或未进行的检查项目在检查结果栏打"-";无问题或合格的检查项目在检查结果栏

打"√";有问题或不合格的检查项目在检查结果栏打"×",并在备注中说明。 注2:当检查项目出具有专项报告时,应附该专项报告。

_________________________________

11

共 页 第 页

www.bzfxw.com

ICS 23.020.30 J 74

备案号:33698-2012

江苏省地方标准

DB32/ 2037—2012

低温绝热气瓶定期检验要求

Requirements of inspection for cryogenic insulation cylinder

2012 - 03 - 31发布 2012 - 05-31实施

目 次

1 范围..............................................................................1 2 规范性引用文件....................................................................1 3 基本要求..........................................................................3 3.1 3.2 3.3 3.4

检验机构和检验人员............................................................检验周期......................................................................检验项目......................................................................检验安全......................................................................

3 3 3 3

4 检验程序..........................................................................4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8

检验准备......................................................................内外部检查....................................................................真空度检测....................................................................安全附件检查与校验............................................................管路及阀门检查................................................................附件组装与脱脂................................................................气密性试验....................................................................静态蒸发率检测................................................................

4 4 4 5 5 5 6 6

5 检验结果的处理....................................................................6 5.1 5.2 5.3 5.4

结论判定......................................................................检验报告......................................................................不合格气瓶处理................................................................标志标贴......................................................................

6 6 6 6

6 检验报告的样式....................................................................7 附录A(规范性附录) 低温绝热气瓶外壳凹陷尺寸的测量方法..............................8 附录B(资料性附录) 低温绝热气瓶定期检验报告.......................................10

前 言

本标准第3章、第4章、第5章为强制性条文。

本标准按GB/T1.1-2009《标准化工作导则 第1部分:标准的结构和编写》的规定编制。 本标准由江苏省特种设备安全监督检验研究院常州分院提出。 本标准起草单位:江苏省低温绝热设备产品质量监督检验中心、江苏省特种设备安全监督检验研究院常州分院、查特深冷工程系统(常州)有限公司、张家港中集圣达因低温装备有限公司、常州博朗低温设备有限公司。

本标准起草人:李秀中、毛小虎、宁晔、赵耀明、顾志军、王渤、徐惠新、蔡浩、魏蔚、徐国强、朱燕梅。

低温绝热气瓶定期检验要求

1 范围

本标准规定了在用低温绝热气瓶定期检验的基本要求、检验程序、检验结果的处理和检验报告的样式。

本标准适用于盛装介质为液氧、液氮、液氩、二氧化碳、氧化亚氮、液化天然气(LNG)等低温液体,设计温度不低于-196℃,在正常环境温度即(-40~60)℃下使用,公称容积大于等于10L,公称工作压力为(0.2~3.5)MPa,可重复充装的焊接绝热气瓶和车用液化天然气绝热气瓶的定期检验。 2 规范性引用文件

下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅所注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。

GB/T 12137 气瓶气密性试验方法

GB/T 18443.2 真空绝热深冷设备性能试验方法 第2部分:真空度测量

GB/T 18443.5 真空绝热深冷设备性能试验方法 第5部分:静态蒸发率测量 JB/T 4730.5 承压设备无损检测 第5部分 渗透检测 JB/T 6896 空气分离设备表面清洁度 3 基本要求

3.1 检验机构和检验人员

3.1.1 进行低温绝热气瓶(以下简称:低温气瓶)定期检验的检验机构,须经国家特种设备安全监察部门核准,并具备按本标准开展检验的能力。

3.1.2 低温气瓶的检验人员须持有国家特种设备安全监察部门颁发的,具有低温气瓶检验资质的检验资格证书。 3.2 检验周期

低温气瓶的定期检验周期应符合国家气瓶安全技术规范的要求。当低温气瓶在使用过程中受到严重损伤,或对其绝热性能或安全性能有怀疑时,应提前进行检验。 3.3 检验项目

低温气瓶的定期检验项目包括内外部检查、真空度检测、安全附件检查和校验、管路与阀门检查、附件组装与脱脂、气密性试验、静态蒸发率检测。 3.4 检验安全

3.4.1 全部检验工作应确保低温气瓶不受损伤、不被油脂污染。

3.4.2 检验前,低温气瓶的余液(气)应完全排空,且瓶内温度应与正常环境温度一致。

3.4.3 检验前,盛装液氧、液化天然气的低温气瓶须使用氮气置换。 4 检验程序 4.1 检验准备

4.1.1 审核低温气瓶的出厂文件、前次定期检验报告、安全附件校验报告、修理情况等资料。

4.1.2 了解低温气瓶的运行情况、使用频率、有无异常现象发生、静态蒸发率变化情况、外壳有无结露和结霜等现象。

4.1.3 检查低温气瓶的制造标志和检验标志是否符合要求,检查情况应予登记。

4.1.4 检验前,应卸下安全阀、压力表、爆破片、液位计和调压阀等可拆卸的附件,并将气瓶表面的污垢、沾染物等有碍表面检查的杂物清除干净。

4.1.5 如果检查中发现有非法制造或非法进口的低温气瓶、制造标志不符合要求的低温气瓶、制造标志模糊不清的低温气瓶、非法改造的低温气瓶、实际充装介质与允许充装介质不符的低温气瓶以及有关规定不准再使用的低温气瓶,检查后不予检验,按报废处理。 4.2 内外部检查

4.2.1 采用目测或5~10倍放大镜对低温气瓶外部进行以下检查:

a) 检查低温气瓶外壳的对接焊缝、阀座与瓶体的角焊缝表面有无裂纹、咬边等焊缝缺陷。如发现

有裂纹,应对裂纹两侧各100mm范围内按JB/T 4730.5进行渗透检测;对发现有咬边、弧坑及其他有怀疑部位应按JB/T 4730.5进行渗透检测。

b) 检查低温气瓶外壳表面是否存在变形、凹陷、凹坑、机械损伤。

c) 检查螺纹是否开裂、磨损、变形或损伤。当螺纹存在磨损或其它损伤时,可用与原螺纹一致的

丝锥修复,修复后用量规检验。

d) 检查低温气瓶护罩、底部支座焊缝有无开裂、变形、损伤、脱落等现象。

4.2.2 用内窥镜检查低温气瓶内胆母材和焊缝的表面情况,应无裂纹、变形、机械损伤、杂物等。应对内胆的角焊缝和可疑部位照相,并对照片进行分析,照片应作为检验记录保存。 4.2.3 当检查发现下列情况之一时,该低温气瓶为不合格:

a) 低温气瓶焊缝有裂纹时;

b) 外壳凹陷深度大于或等于12mm,并且凹陷长度大于或等于外壳周长的13%时(外壳凹陷尺寸的

测量方法见附录A);

c) 螺纹有开裂或其他严重损伤时;

d) 护罩、底部支座因开裂、变形、腐蚀或其他机械损伤而失去作用的。 4.3 真空度检测

4.3.1 当存在下列情况之一时,应按GB/T 18443.2进行夹层常温真空度检测:

a) 距上次夹层真空度测试已有6年及以上的; b) 上次检验后瓶体经过修理的;

c) 使用中瓶体部位发生结露、结霜现象的; d) 对夹层真空度和绝热性能有疑问的。 夹层常温真空度小于或等于5Pa为合格。

4.3.2 夹层真空度检测在静态蒸发率检测前进行,当检测不合格时,应查明原因。对于因夹层材料放气或吸附剂失效导致不合格的,应投放吸附剂并且进行抽真空处理;对于因夹层密封损坏导致不合格的,按不合格气瓶处理。 4.4 安全附件检查与校验 4.4.1 基本要求

低温气瓶安全附件应完好、齐全、选型正确,并且在校准或校验有效期内。 4.4.2 安全阀

4.4.2.1 目测检查安全阀外观情况。安全阀外观应良好、无泄漏和堵塞现象、在校验有效期内且铅封完好。当不满足上述要求时,应予修校或更换。

4.4.2.2 安全阀每年至少校验一次,整定压力应符合气瓶的设计要求。 4.4.3 压力表

4.4.3.1 目测检查压力表外观情况。压力表的外壳应无严重腐蚀或损坏、表盘玻璃破裂、刻度不清、指针扭曲断裂、卸压后指针不回零位、铅封损坏等现象。有上述情况之一时,应予更换。

4.4.3.2 压力表每6个月至少检定一次,其精度不低于2.5级,量程为公称工作压力的1.5~3.0倍。 4.4.4 爆破片

目测检查爆破片外观情况。爆破片表面应无划痕,安装方式、方向、位置正确,爆破压力和爆破温度应符合设计要求,且在规定的使用期限内(制造单位未规定使用期限时,使用期限不超过3年)。当不满足上述要求时,应予更换。 4.4.5 液位计

目测检查液位计外观情况。液位计的外壳和保护罩应完好,液位计指示应清晰,数字式液位计显示应清晰、完整。如出现指示不清、假液位、表盘玻璃破裂等现象,应予修理或更换。 4.5 管路及阀门检查

4.5.1 采用目测或5~10倍放大镜检查,管路,接管和焊缝表面等处应无裂纹、压扁、堵塞等现象。检验不合格时,应按不合格气瓶处理。

4.5.2 阀门应启闭自如,不得有泄漏,采用目测或5~10倍放大镜检查,阀体和螺纹应无裂纹、变形或其它严重损伤。不符合要求时,应更换损坏的部件或按不合格气瓶处理。

4.5.3 将调压器解体清洗、更换阀头密封垫,目测检查外观情况。调整螺杆和螺母的螺纹应完好,鼓膜片及阀头应完好,弹簧无异常变形、裂纹、疲软等缺陷。不符合要求时,应修复或更换。调压器组装后应进行设定点调整,设定方法和设定压力应符合制造单位气瓶维护说明书的要求。 4.6 附件组装与脱脂

4.6.1 所有从瓶体上拆卸的附件经检验合格后,应按气瓶维护说明书的要求与瓶体组装。修理或更换的安全附件、阀门部件等应选型正确,所用的密封件应与气瓶盛装的介质相适应。组装过程中严禁金属屑等杂物掉入气瓶内胆。

4.6.2 对盛装液氧的气瓶,应按JB/T 6896的脱脂清洗要求对气瓶外壳、安全附件、管路、阀门及各拆装接口进行脱脂、去油处理。处理后采用白色、清洁、干燥的滤纸擦抹脱脂表面,纸上应无油脂和污物,确认合格后方可组装。 4.7 气密性试验

4.7.1 低温气瓶经附件组装与检查合格后,按GB/T 12137进行气密性试验,并符合下列要求:

a) 试验压力为气瓶的公称工作压力; b) 试验介质宜采用干燥、洁净的氮气; c) 试验方法采用涂液法。

4.7.2 当因附件组装不当而产生泄漏现象时,应重新组装后再进行试验。 4.8 静态蒸发率检测

4.8.1 低温气瓶气密性试验合格后,应按GB/T 18443.5进行静态蒸发率检测。静态蒸发率应小于或等于1.5倍的气瓶产品出厂标准规定的合格指标,并且焊接绝热气瓶还应同时符合表1的规定,车用液化天然气绝热气瓶还应同时符合表2的规定。

4.8.2 静态蒸发率检测过程中,如果低温气瓶瓶体上发生结霜现象时,应按不合格气瓶处理。

表1 焊接绝热气瓶静态蒸发率合格指标

公称容积L 静态蒸发率

10 8.2

25 6.3

50 4.5

100 4.2

150 3.8

175 3.2

200 3.0

300 2.9

450 2.7

≤%/d

表2 车用液化天然气绝热气瓶静态蒸发率合格指标

公称容积L 静态蒸发率≤%/d

50 5.4

100 5.1

150 5.1

200 4.8

250 4.8

300 4.8

350 4.5

400 4.5

450 4.2

500 4.2

4.8.3 检测完成后,瓶内应保留部分氮气,瓶内压力应为(0.05~0.1)MPa。对于盛装液化天然气的气瓶,应进行瓶内气体分析,取样时应在出气口抽取,瓶内氧气含量应小于或等于3%。 5 检验结果的处理 5.1 结论判定

当4.2~4.8的各检验项目全部合格,检验结论为合格。 5.2 检验报告

检验完成后应出具检验报告,气瓶产权单位(或气瓶使用单位)和检验机构各保存一份。 5.3 不合格气瓶处理

检验不合格的气瓶应修理或报废。当气瓶送修时,由检验机构直接将气瓶交与有资质的修理单位。当气瓶报废时,检验机构应按国家气瓶安全技术规范的要求,将气瓶进行报废处理后交气瓶产权单位。 5.4 标志标贴

检验合格的低温气瓶应按国家气瓶安全技术规范的规定,装检验标志环,并在标志环上打检验钢印。当气瓶的警示标志、标贴存在缺失、损坏、脱落现象时,应予修缮。 6 检验报告的样式

见附录B。

附 录 A

(规范性附录)

低温绝热气瓶外壳凹陷尺寸的测量方法

A.1 凹陷深度的测量方法

量具为游标卡尺、直尺。直尺应沿气瓶轴向放置,直尺长度应大于凹陷轴向长度的三倍,如图A.1

所示。

1——游标卡尺

2——钢直尺

3——气瓶外壳

4——凹陷

5——凹陷深度

图A.1

A.2 凹陷长度的测量方法

量具为游标卡尺。游标卡尺沿气瓶轴向放置,测量凹陷沿气瓶轴向的最大长度,如图A.2.a)所示;游标卡尺沿气瓶周向放置,测量凹陷沿气瓶外壳周向的最大长度,如图A.2.b)所示。取两者的最大值作为凹陷的长度。

a)

b)

1——游标卡尺

2——气瓶外壳

3——凹陷

4——凹陷轴向最大长度

5——凹陷周向最大长度

图A.2

附 录 B

(资料性附录)

低温绝热气瓶定期检验报告式样

报告编号:

低温绝热气瓶定期检验报告

送检单位:

气瓶型号:

安全条码号:

出厂编号:

检验日期:

(检验机构名称)

8

注 意 事 项

1、本报告书为对在用低温绝热气瓶进行定期检验的结论报告。

2、报告书应当由计算机打印输出,或用钢笔、签字笔填写,涂改无效。

3、本报告书无检验、审核、签发人员签字和检验机构的核准证号、检验专用章或者公章无效。 4、本报告书正本由气瓶产权单位(或气瓶使用单位)保存,副本由检验机构保存。

5、受检单位对本报告结论如有异议,请在收到报告书之日起15日内,向检验机构提出书面意见。

单位地址: 联系电话: 邮政编码:

9

www.bzfxw.com

报告编号:

低温绝热气瓶定期检验结论报告

送检单位 产权单位

出厂编号

(或使用单位)

制造单位

制造日期

气瓶型号

安全条码号 充装介质

公称工作压力公称容积最大充装量气瓶标记 检验依据:

资料审查 上次检验日期

检验发现的问题位置、程度、性质及处理意见(必要时附图或附页):

检验结论

下次检验日期

检验: 日期:

(检验机构名称)

机构核准证号:

审核: 日期:

(检验机构章) 日期:

签发: 日期:

共 页 第 页

10

报告编号:

低温绝热气瓶定期检验报告附页

检查项目

外壳的对接焊缝、角焊缝裂纹、泄漏

检查结果

备注及问题说明

内外部检查

外壳的变形、凹陷、凹坑、机械损伤 螺纹的开裂、磨损、变形或损伤

护罩、底部支座的开裂、变形、损伤、脱落 内胆母材表面的裂纹、变形、杂物 内胆焊缝的表面的裂纹、损伤等外观缺陷 安全阀

安全附件、管路及阀门检查 附件组装与脱脂

压力表 爆破片 液位计

管路接管角焊缝的裂纹 管路接管的损伤、堵塞 阀体和螺纹的裂纹

阀体和螺纹的变形、机械损伤 螺纹的磨损、机械损伤 阀门的启闭、泄漏 调压阀性能测试 修理或更换部件的选型 脱脂、去油处理

渗透检测 气密性试验 真空度 静态蒸发率

注1:没有或未进行的检查项目在检查结果栏打"-";无问题或合格的检查项目在检查结果栏

打"√";有问题或不合格的检查项目在检查结果栏打"×",并在备注中说明。 注2:当检查项目出具有专项报告时,应附该专项报告。

_________________________________

11

共 页 第 页

www.bzfxw.com


相关内容

  • 汽车离合器打滑故障诊断与维修
  • 汽车离合器打滑故障诊断与维修 姚国辉 (浙江交通技师学院,浙江金华321015) 摘 要:离合器安装在发动机与变速器之间,是发动机与传动系之间切断和传递动力的部件.手动挡汽车在行驶中因路况不同 为了适应道路行驶,需要频繁地变换挡位,同时离合器使用频繁,会出现许多故障.本文就离合器打滑故障进行分析. ...

  • 气瓶安全监察规程
  • 国家质量技术监督局关于颁发<气瓶安全监察规程>的通知 质技监局锅发[2000]250号 ),:各省.自治区.直辖市质量技术监督局,国务院各有关部.委.局1989年12月22日原劳动部颁发的,,要作用.但是,,,原规程的部分内容已不能适应当前工作的需要.为此,.现将修订后的<气瓶安全 ...

  • 气瓶与移动压力容器
  • 第六章 气瓶与移动压力容器 6.1 气瓶种类.结构与技术参数 气瓶定义--是一种经常搬动的非固定式容器,公称容积不大以1000L ,用于盛装气体.液化气体和标准沸点等于或低于60℃液体的可重复性充装的移动性压力容器. 6.1.1气瓶监察规程 目前与气瓶及移动容器有关的安全监察规程有: <溶解乙 ...

  • 特种设备检验周期
  • 锅炉 1.<蒸汽锅炉安全技术监察规程>第202条;在用锅炉一般每年进行一次外部检验,每两年进行一次内部检验,每六年进行一次水压试验. ; 当内部检验和外部检验同在一年进行时,应首先进行内部检验,然后再进行外部检验. ; 电力系统的发电用锅炉内部检验和水压试验周期可按照电厂大修周期进行适当 ...

  • 气瓶设计文件鉴定内容与要求
  • 特种设备安全技术规范 TSG R1003-2004 附件1 气瓶设计文件鉴定内容与要求 - 1 - TSG R1003-2004 特种设备安全技术规范 - 2 - 特种设备安全技术规范 TSG R1003-2004 附件2 气瓶设计文件修改范围 一.以下情况视为新设计: (一)改变设计壁厚: (二) ...

  • 撬装式LNG汽车加气站的应用
  • 1 撬装式LNG加气站简介 为响应国家科技部推广应用清洁燃料汽车的号召,天然气汽车在我国很多城市得到迅猛发展,在我国,北京.乌鲁木齐.长沙.贵阳.杭州等地正在积极推广LNG汽车及加气站,并已建成多座LNG加气站.这些加气站中,除了常规的各设备在现场安装组成完整系统的加气站外,还有事先将加气站各种设备 ...

  • 常用建筑材料进场复验项目汇总表00000
  • 号 1 类别 材料名称 进场复验项目 组批原则及取样规则 (1)按同一生产厂家.同品种.同等级.同批号连续进场的水泥,袋装水泥不超过200t 为一批,散装水泥不超过500t 为一批,每批抽样不少于一次. (2)随机从不少于20袋中各取等量水泥,经混拌均匀后,再从中称取不少于12kg 的水泥作为试样. ...

  • 江苏石油分公司加气站安全管理规定
  • 中国石油化工股份有限公司江苏石油分公司 石化股份苏安„2012‟428号 关于印发<江苏石油分公司 加气站安全管理规定>的通知 各分公司,机关各处室(专业中心): 现将<江苏石油分公司加气站安全管理规定>印发给你们,请认真贯彻执行. 二○一二年四月二十六日 - 1 - 企业制 ...

  • 高纯氩气技术说明书
  • 高纯氩气技术说明书 第一部分化学品及企业标识 化学品中文名称:工业氩 化学品俗名或商品名:纯氩,高纯氩 化学品英文名称:Argon 生产商:广州市谱源气体有限公司 产品信息(查询电话):[1**********] 分子式:Ar 分子量: 第二部分成分/组成信息 纯品 化学品名称: 工业氩 有害物成分 ...